l

Switch on the main disconnect switch, then release the emergency
stop button. Restart the pump by pressing on Start button on the
remote control. If the pump does not start, press on emergency
stop button, switch off and padlock the main disconnect switch,
switch off the customer’s power supply and put the label
“maintenance processing”. Call the BUSCH Semicon service team
in charge of the maintenance of the pumps.

l

If the external thermal protection B1 is engaged, check that the
water flow shows 2l/min on the flowmeter. If not, set the water
flow at 1,5 l/min according to the instruction (see chapter
“Checking the cooling liquid flow”). Check the wiring system of
the thermal protection by opening the side face (Type 3 of
electrical work). Wait a few hours for the cooling of the protection,
then press on Start button to restart the pump.

Safety interlock description

Interlock event

Sensor

Response

Emergency

Stop

EMO S/W

EMO Button Pushed during pump

running

H

Motor

overcurrent

Frequency

inverter

Inverter default and remove

power to motor

s

Motor overtem-

perature

(t° > 150°C)

Thermo

switch B1

(klixon)

Contactors open and remove

power to motor

s

Discharge

overpressure

Pressure

sensor B4

Depends on alarm function set in

the PLC for overpressure
Set at factory: General stop ie. the

contactors open and remove

power to motor

S

Motor

overcurrent

Frequency

inverter

Depends on alarm function set in

the PLC for overcurrent
Set at factory: General Stop ie. the

contactors open and remove

power to motor

S

Cylinder

overtemperature

Temperature

sensor B5

Depends on alarm function set in

the PLC for cylinder temperature
Set at factory: General Stop ie. the

contactors open and remove

power to motor

S

Cooling water

flow low

Water

flowmeter B2

Depends on alarm function set in

the PLC for water flow
Set at factory: General Stop ie. the

contactors open and remove

power to motor

S

Nitrogen flow

too low

Nitrogen

flowmeter B3

Depends on alarm function set in

the PLC for nitrogen flow
Set at factory: None ie. the pump

continues running with alarm

S

H= Hardware, S= Software

Position of the pump gravity center

l

The gravity center of the BC 0200 F pump is determined according
to the drawing

Installation of the vacuum pump in a
seismic zone

l

Convey the pump to its final location with a pallet truck before
removing it from its support

l

Unscrew the fixing screws of the pump on the transport pallet and
remove the machine from its support with an appropriate lifting
system by using the lifting brackets made for this purpose

l

Check that the wheels no longer touch the ground

CAUTION

The vacuum pump is fixed to the ground with four M10 screws, one
screw per bracket. The fixing screw must stand a 1200 N tensible
force (per bracket).
The final user must adapt the type of screws depending on the
ground material.

Information over the lubricants

Oil

Busch YLC 250 B n°.-art. 0831 131 400 (0.5l of Busch YLC 250 B)

Quantity: BC 0200 F : 0,12 l

Replacement: After 16'000 h (see Maintenance chapter, page 15)

Decommissioning procedure

When the product arrives at the end of the lifetime, it is necessary to
proceed to the decontamination of the vacuum pump

Safety

BC 0200 F

Page 8

0870767417 (En)

ELECTRICAL       

POW ER 

Main 

switch  S1 

Frequency 

inverter 

DP Motor 

Klixon 

B1 

ELECTRICAL PRINCIPLE OF OPERATION 

Emergency 

stop 

Main 

Circuit 

Breaker 

Q1 

Wheel 

Adjusting nut 

Lifting bracket 

Dimensions :

L1 : 264 [mm]
L2 : 132 [mm]
L3 : 497 [mm]

h  : 97.7 [mm]

W : 130 kg

Center of gravity posi

Ɵ

on

CG : Center of gravity
W  : Weight of vacuum pump

Summary of Contents for COBRA BC 0200 F

Page 1: ...Instructions Screw Vacuum Pumps COBRA BC 0200 F Busch Manufacturing Korea Ltd 189 51 Soicheon ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870767417 190605 Original instructions Subj...

Page 2: ...tions on operation 14 Application 14 Switching the vacuum pump on off 15 First start up of the system 15 Switching the system off 15 Maintenance 15 Maintenance program 16 Weekly 16 Monthly 16 Yearly 1...

Page 3: ...racket OFP Oil filler plug OSG Oil sight glass PS Discharge pressure switch CAO Extracting ventilator CPC PLC connection ES Emergency stop button EMO MB On Off switch Main circuit breaker RC LCD DGF D...

Page 4: ...BC 0200 F Page 4 0870767417 En MB CPC DPS DGF DGR2 DGR1 PSA TS CWR CWM VFD...

Page 5: ...not suitable for continuous duty at a pressure more or equal than 150 hPa mbar Caution the operating cycle of 150 hPa mbar must not exceed more than 5 min For other applications contact your Busch rep...

Page 6: ...valve optional at the exhaust traps the condensate in the pump when the pump is switched off The LCD controller processes the data of the sensors see chapter Communication with the equipment as follo...

Page 7: ...ntact exceed the limits in Table A5 1 of Appendix 5 SEMI S2 guideline Lock Out Tag Out procedure Type 1 of electrical work l Stop the pump with the remote control or with the stop button press on STOP...

Page 8: ...ie the contactors open and remove power to motor S Cooling water flow low Water flowmeter B2 Depends on alarm function set in the PLC for water flow Set at factory General Stop ie the contactors open...

Page 9: ...aws Appliance after warehousing Prior to reoperate a vacuum pump which remained outside the buiding for a certain period of time make sure to let it stand at ambient tempe rature in a room for a whole...

Page 10: ...l must be disposed of in accordance with local and national regulations This handbook is contained in the delivery package Storage Temporary storage l Make sure that the intake and exhaust flanges are...

Page 11: ...by the adjustment stroke 15 mm of the four machine foots l Make sure that the four rollers do not touch the ground NOTE In order to ensure the fixation of the pump to the ground it is possible to use...

Page 12: ...nnection diameter 3 8 NPT Nitrogen connection The nitrogen is connected with a pipe leakproof against oxygen Connection diameter 1 4 NPT Electrical connection Checks l Make sure that the regulations o...

Page 13: ...e installation handbook is of informative nature only Check the oil level with the help of the oil sight glass OSG on the vacuum pump CAUTION Before you change the type of oil make sure that the new t...

Page 14: ...tain quantity of liquid If the pump has sucked in liquid a short drying time is necessary at the end of the procedure The allowed maximum inlet gas temperature depends on the inlet pres sure and the t...

Page 15: ...minated with foreign materials that are dangerous to health the oil and condensates will also be contaminated These foreign materials can infiltrate the pores recesses and other internal spaces of the...

Page 16: ...essary l Check the seals and replace if necessary l Check the intake and discharge lines and clean or replace if necessary Every 16 000 hours of operation at the latest after 4 years l Drain the oil s...

Page 17: ...the sealing washer of the magnetic plug is not damaged replace it if necessary l Refit the magnetic plug and tighten up l Make sure that the sealing washer on the drain plug is undamaged and correctly...

Page 18: ...that the various protective elements stoppers or adhesive tapes have been removed l Switch on the vacuum pump by following the procedure described in the chapter Installation and start up Dismantling...

Page 19: ...ntaminated or polluted oil can lead to hazardous pump conditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check...

Page 20: ...Nominal motor speed min 1 4570 Noise level EN ISO 2151 dB A 60 Ambient temperature C F 10 40 32 104 Maximal counter pressure Discharge bar 0 2 Cooling water requirement l min min 2 0 Cooling water pr...

Page 21: ...and electronic equipment and following the standards Standard Title of the standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design EN ISO 13857 2008 Safety of machi...

Page 22: ...Note...

Page 23: ...Note...

Page 24: ...myun Icheon si Gyunggi do 467 813 Republic of Korea Phone 82 31 645 2700 Fax 82 31 631 2898 e mail busch busch co kr Malaysia Busch Malaysia Sdn Bhd 4 6 Jalan Taboh 33 22 Seksyen 33 Shah Alam Technolo...