
57
A12192
6.3.9.1.
Filter
NOTE
: The daily duct assessment will occur even if static pressure monitoring is
disabled. This is done to ensure that the system will continue to provide proper
airflow for all installed equipment, since duct system changes may occur at any
time, such as opened or closed registers.
With this option, the installer has the option of selecting pressure monitoring, the
type of filter installed, and the time interval for cleaning. After the selections are
made, touch
SAVE
.
S
Pressure Monitoring
(not available or effective with air cleaners that do not
use filter media, such as Electric Air Cleaners): Enable or Disable
d
Default = Enable
S
Clean Interval:
Selectable from 1 to 18 months
d
Default = 3 months
S
Filter Type:
Air Filter, Electric Air Cleaner or Air Purifier
d
Filter type is selected during installation; otherwise default = air filter
Summary of Contents for Evolution Connex SYSTXBBECC01-
Page 34: ...25 A12186 ...
Page 103: ...94 A160170 NIM Chart ...
Page 104: ...95 A160171 Wiring Diagram Single Stage Non Communicating Heat Pump NIM ...
Page 105: ...96 A160172 Wiring Diagram Two Stage Non Communicating Heat Pump NIM ...
Page 106: ...97 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation ...
Page 107: ...98 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown ...
Page 110: ...101 NOTES ...
Page 111: ......