42
CFM/ton, but will vary if a 2--stage outdoor unit is used. The
MAX
airflow is a
fixed 400 CFM/ton. No dehumidification airflow reduction is performed.
NOTE
: For Geothermal Heat Pumps, the airflow labels have been changed from
EFF325 and EFF350 to EFF1 and EFF2, respectively. Nominal geothermal system
airflows for these settings tend to be different than the typical 325 and 350 CFM/ton
values.
The dehumidify airflow, when set to
NORMAL
, the airflow is allowed to adjust to
a minimum to satisfy the dehumidification call. When set to
HIGH
, the minimum
airflow during the dehumidify mode is increased to reduce duct and register
sweating. Also the airflow increases minimum airflow during normal cooling
operation to help reduce duct sweating.
After the selections are made, touch
SAVE
.
S
Cool:
Quiet, Comfort, EFF325 (or EFF1), EFF350 (or EFF2), or Max
d
Default = Comfort
S
HP Heat:
Comfort, EFF325 (or EFF1), EFF350 (or EFF2), or Max
d
Default = Comfort
S
Dehumidify:
Normal or High
d
Default = Normal
6.3.3.3.
Furnace Staging
This option controls the staging of the furnace and selects the minimum amount of
time low stage must operate before high stage is activated.
SYSTEM
setting will
allow the EvolutionZone Control to determine furnace staging.
LOW
will only run
the low stage of furnace heat.
LOW--MED
will run the low and medium stages (2
stages of heat).
MED
will only run the medium stage of heat.
MED--HIGH
will run
the medium and high stages (2 stages of heat).
HIGH
will only run the high stage
of furnace heat.
NOTE
: Two--stage furnace has
LOW
and
HIGH
selections only.
Summary of Contents for Evolution Connex SYSTXBBECC01-
Page 34: ...25 A12186 ...
Page 103: ...94 A160170 NIM Chart ...
Page 104: ...95 A160171 Wiring Diagram Single Stage Non Communicating Heat Pump NIM ...
Page 105: ...96 A160172 Wiring Diagram Two Stage Non Communicating Heat Pump NIM ...
Page 106: ...97 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation ...
Page 107: ...98 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown ...
Page 110: ...101 NOTES ...
Page 111: ......