16
NOTE
: Once the Evolution Connex Control is secured to wall with the backplate
assembly (snapped together), care must be taken not to bend or break the
interlocking tabs when removing.
4.6.
Humidifier Connections
A 24VAC bypass or fan powered humidifier may be installed.
NOTE
: Do NOT use a traditional humidistat to control humidifier operation. If a
humidifier is installed, let the Evolution Connex Control operate humidifier.
4.6.1.
Bypass Humidifier
A bypass humidifier should be wired directly to the furnace or fan coil HUM and
24VAC COM terminals. The Evolution Connex Control will automatically energize
the HUM output during a call for humidification.
4.6.2.
Fan Powered Humidifiers
Most fan powered humidifiers produce internal 24VAC in order to energize upon a
switch or contact closure. For this application, a 24VAC N.O. Isolation Relay
(DPST) MUST be used to prevent mixing the internal humidifier power with the
indoor equipment transformer. Applying 24VAC isolation relay coil to furnace or
fan coil HUM and COM terminals will allow the Evolution Connex Control to
automatically energize the HUM output during a call for humidification. The N.O.
relay contacts will be used to energize the humidifier. See fan powered humidifier
installation instructions for more details.
5. Commissioning
This section addresses initial power up (or commissioning) of a new Evolution
Connex Control. The control will communicate and identify all components in the
Evolution System. The following is a typical example for a communicating
variable--speed furnace / fan coil with a 2--stage air--conditioner / heat pump
Summary of Contents for Evolution Connex SYSTXBBECC01-
Page 34: ...25 A12186 ...
Page 103: ...94 A160170 NIM Chart ...
Page 104: ...95 A160171 Wiring Diagram Single Stage Non Communicating Heat Pump NIM ...
Page 105: ...96 A160172 Wiring Diagram Two Stage Non Communicating Heat Pump NIM ...
Page 106: ...97 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation ...
Page 107: ...98 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown ...
Page 110: ...101 NOTES ...
Page 111: ......