3-6
Section 3: Pinsetter Electronics
(6)
Not Used -
Connection is not used.
(7)
Scorer COM-Line (JDP 2) -
Not used
(8)
Scorer COM-Line (JDP 1) -
Connection for communication to the scoring system.
(9)
Ball Rack /Foul/Ball Detectors -
Connection for inputs from the Foul Unit, Ball Detectors and
bowler’s reset button on the ball rack. 24VAC power used to energize power relay located at the
ball rack which, in turn, powers the ball lift motor and hand blower is also supplied through this
connector. Refer to cables 55-143016-000, 55-143016-100, 55-143016-200.
(10)
Pinsetter “A” Connections -
The cabling from “Pinsetter “A” connectors attach to one of the
pinsetters of the lane pair. When the controller is mounted at the rear (back) of the machines,
the connectors are used for the odd lane (left) pinsetter. When the controller is mounted at the
front of the machines the connectors are used for the even lane (right) pinsetter.
(11)
Pinsetter “B” Connections -
The cabling from “Pinsetter “B” connectors attach to one of the
pinsetters of the lane pair. When the controller is mounted at the rear (back) of the machines,
the connectors are used for the even lane (right) pinsetter. When the controller is mounted at
the front of the machines the connectors are used for the odd lane (left) pinsetter.
Summary of Contents for StringPin
Page 1: ...Service Manual February 2019 55 900001 000 StringPin Pinsetter Ten Pin...
Page 6: ...6 StringPin Pinsetter Service Manual Intentionally Blank Page...
Page 35: ...Section 2 Overview 2 25 1 REAR ACCESS Figure 2 25 Machine Rear Access 1 REAR ACCESS...
Page 40: ...2 30 Section 2 Overview Intentionally Blank Page...
Page 102: ...4 16 Section 4 Adjustments Intentionally Blank Page...
Page 112: ...5 10 Section 5 Maintenance Service Intentionally Blank Page...
Page 126: ...7 8 Section 7 Cables Intentionally Blank Page...