Section 04 ENGINE MANAGEMENT SYSTEM
Subsection 03 (MONITORING SYSTEM/FAULT CODES)
NOTE:
A minimum of 3 HI - LO toggles must be
completed within 2 seconds.
If there is no fault code, the NO ACTIVE P_CODE
will be displayed.
If there is any fault code, it will be displayed.
vmr2008-134-003_b
If there is more than one fault code, the next one
will automatically appear after a small delay.
vmr2008-134-003_c
Once the last fault code is displayed, the gauge
will display END OF P_CODE MODE then it will
default back to normal operation.
vmr2008-134-003_d
NOTE:
To quickly exit the on-board diagnostic
mode, press and HOLD the mode button.
SPECIFIC FAULT CODES
TPS (Throttle Position Sensor) Faults
Faults which are reported in B.U.D.S. fall into two
groups: TPS faults and adaptation faults. These
are displayed on the B.U.D.S. system as TPS OUT
OF RANGE and TPS ADAPTATION FAILURE.
TPS “OUT OF RANGE” Fault
It is caused by the sensor reading going out of its
allowable range. This fault can occur during the
whole range of movement of the throttle.
To diagnose this fully, it is recommended to oper-
ate the throttle through its full range. It is also rec-
ommended to release the throttle quickly as this
may also reveal a fault that is intermittent.