![BRP Evinrude E-TEC Manual Download Page 188](http://html1.mh-extra.com/html/brp/evinrude-e-tec/evinrude-e-tec_manual_2820522188.webp)
Cooling System
Temperature Sender Servicing
188
Temperature
Sender Servicing
Removal
Loosen sensor and remove by hand. Use care to
avoid breaking threads.
Clean sensor threads, sensor, and sensor cavity.
Installation
Fill bottom of sensor cavity with 0.7 cc of
Thermal
Joint Compound
, P/N 322170. Sensor cavity
should be filled to 1 inch (25 mm) below the top
edge of the cavity.
Install sensor. DO NOT use gasket sealing com-
pound. SLOWLY tighten temperature sensor to a
torque of 50 to 70 in. lbs. (5.6 to 8.0 N·m).
Wait 10 minutes for trapped air to bleed from cav-
ity. Thermal compound may seep past threads.
Retighten sensor.
008346
1.
Temperature sensor
2.
Sensor cavity
3.
Thermal joint compound
007049
1 in.
(25 mm)
3
2
1