1-7
Confidential
2.2
Error Code Cause and Remedy
2.2.1 Recoverable User Check Errors
These errors are recoverable by following the message indicated on the LCD or following the
items indicated in User Check.
■
Error code 67
The toner of the toner cartridge is low. (The toner sensor delects the nearly empty.)
■
Error code 75
The machine is cooling down inside for protection.
The machine indicates "Cooling Down" in one of the conditions below.
(1) The temperature inside the machine is too high.
(2) Both ends of the heat roller are at different temperatures.
(3) The paper media is replaced with different Paper size media.
2.2.2 Service Call Error
Check the User Check items first. If the same problem occurs follow each procedure in the
order of the number described in the Step column in the table below.
■
Error code 50
Replacement time of the drum unit. (The drum counter reached the upper limit.)
Toner Low
Prepare New Toner Cartridge
User Check
• Prepare a new toner cartridge. If the toner is empty, Replace it.
Cooling Down
Wait for a while
User Check
• After having passed for a while with having turned the power supply on.
Drum End Soon
User Check
• Replace the drum unit with a new one.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...