1-37
Confidential
■
White vertical streaks
■
White horizontal streaks
User Check
• Clean the scanner windows of the laser unit with a soft lint-free cloth.
(
Refer to Fig. 1-6.
)
• Replace the toner cartridge with a new one.
• Check the machine’s environment. High temperature and high
humidity conditions can cause this problem.
• Damp (wet) paper might be used. Try to change to freshly unpacked
paper.
• Check there is no dust in the gap between the toner cartridge and
drum frame.
Step
Cause
Check
Result
Remedy
1
Condensation
Has condensation
occurred inside the
machine?
Yes
Try to print several pages
or leave the machine 2
hours to allow it to reach
room temperature.
2
Dirt on scanner
windows
Is the scanner windows
dirty?
Yes
Clean the scanner
windows.
3
Transfer failure
Is the transfer roller
scratched?
Yes
Replace the drum unit.
4
Scanner window
of laser unit
failure
Is the problem solved
after replacing the laser
unit?
Yes
Replace the laser unit.
User Check
• Check that the appropriate media type is selected in the printer
driver.
• The problem may disappear by itself. Try printing multiple pages to
clear this problem especially if the machine has not been used for a
long time.
• The drum unit may be damaged. Replace the drum unit with a new
one.
Step
Cause
Check
Result
Remedy
1
Toner cartridge
electrode
connection
failure
Are the electrodes on
the toner cartridge and
machine body dirty?
Yes
Clean both electrodes.
(Refer to
).
2
Drum unit
electrode
connection
failure
Are the electrodes on
the drum unit and
machine body dirty?
Yes
Clean both electrodes.
(Refer to
).
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...