App. 1-19
Confidential
<WSW14>
• Selectors 1 through 4: Frequency band selection for incoming calling signal (CI)
These selectors are used to select the frequency band of CI for activating the AUTO ANS
facility.
In the French models, if the user sets the PBX to OFF from the control panel, the setting
made by selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to
32 Hz. (Even if the setting made by these selectors does not apply, it will be printed on the
configuration list.)
• Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.
Selector No.
Function
Setting and Specifications
1
2
Frequency band selection (lower
limit) for incoming calling signal
(CI)
No. 1 2
0 0: 13 Hz
0 1: 15 Hz
1 0: 23 Hz
1 1: 20 Hz
3
4
Frequency band selection
(upper limit) for incoming calling
signal (CI)
No. 3 4
0 0: 30 Hz
0 1: 55 Hz
1 0: 70 Hz
1 1: 200 Hz
5
I
8
No. of rings in AUTO ANS mode
No. 5 6 7 8
0 0 0 0: Fixed to once
0 0 0 1: 1 to 6 times
0 0 1 0: 1 to 8 times
0 0 1 1: 2 to 8 times
0 1 0 0: 1 to 2 times
0 1 0 1: 1 to 3 times
0 1 1 0: 1 to 4 times
0 1 1 1: 1 to 5 times
1 0 0 0: 2 to 3 times
1 0 0 1: 2 to 4 times
1 0 1 0: 2 to 5 times
1 0 1 1: 2 to 6 times
1 1 0 0: 1 to 10 times
1 1 0 1: 2 to 10 times
1 1 1 0: 3 to 5 times
1 1 1 1: 4 to 10 times
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...