1-12
Confidential
■
Error code 71
Laser unit Polygon mirror motor failure
(Cannot detect the period signal of the polygon mirror motor.)
Error code 72
BD beam detect sensor malfunction
■
Error code 76
Fuser unit failure (The center thermistor detects rapidly rising temperature.)
■
Error code 77
Fuser error code failure (The error history of the fuser unit is deleted.)
Print Unable 71
See Troubleshooting and routine maintenance chapter in User’s Guide.
Print Unable 72
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Laser unit harness connection
failure
Check the two harness connections of the
laser unit and reconnect them.
2
Laser unit failure
Replace the laser unit.
3
Main PCB failure
Replace the main PCB ASSY.
Print Unable 76
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Fuser unit harness connection
failure
Check the harness connection of the fuser
unit and reconnect it.
2
Fuser unit failure
Replace the fuser unit.
Print Unable 77
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Fuser unit failure
Replace the fuser unit.
2
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...