1-13
Confidential
■
Error code 78
Fuser unit failure (The temperature sensor of the fuser unit is broken.)
■
Error code 79
No detection of the internal temperature thermistor.
■
Error code 7A
No detection of the main motor lock signal.
■
Error code 7B
Main PCB failure
Print Unable 78
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Fuser unit failure
Replace the fuser unit.
2
Main PCB failure
Replace the main PCB ASSY.
Print Unable 79
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Harness connection failure of
internal temperature thermistor
Check the harness connection of the internal
temperature thermistor, and reconnect it.
2
Internal temperature thermistor
failure
Replace the internal temperature
thermistor.
3
Main PCB failure
Replace the main PCB ASSY.
Print Unable 7A
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Main motor failure
Replace the main motor ASSY.
2
Main PCB failure
Replace the main PCB ASSY.
Print Unable 7B
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...