App. 1-23
Confidential
<WSW18>
• Selector 1: Header for fax
The setting becomes effective only when do not add the header in the application of the
PC.
• Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the
machine, the machine can detect a CNG signal or no tone for the time length specified by
these selectors. The setting specified by these selectors becomes effective only when
selector 8 on WSW20 is set to "1."
• Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech
models.
• Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.
Selector No.
Function
Setting and Specifications
1
Header for fax
0: With header 1: Without header
2
3
Detection enabled time for CNG
and no tone
No. 2 3
0 0: 40 sec.
0 1: 0 sec. (No detection)
1 0: 5 sec.
1 1: 80 sec.
4
5
Not used.
6
Registration of station ID
0: Permitted
1: Prohibited
7
8
Tone sound monitoring
No. 7 8
0 0: No monitoring
0 1: No monitoring
1 0: Up to phase B at the calling
station only
1 1: All transmission phases both
at the calling and called stations
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...