10. ELECTRIC MECHANISM
BAS-311H
134
Error status #8 Error code appears on the display when the foot switch is depressed.
Probable causes
Check/repair/adjust
Parts to be replaced
1. If the work clamp pulse motor does
not operate and “E300” is
displayed, there is a malfunction of
the power PCB.
Disconnect connectors P1 (POWER2) and P24
(POWER1) from the main PCB, and then turn on
the power switch and check LD1 (red) on the
power PCB.
OK if illuminated.
After checking, turn off the power switch, wait for
one minute or more, and then insert P1 and P24
into the main PCB.
Power PCB assembly
2. If the work clamp pulse motor does
not move and “E300” is displayed,
there is a malfunction of the main
PCB.
a. Disconnect connector P24 (POWER1) from
the main PCB, and check the continuity
between terminals 1 and 2 of P24.
OK if
∞
ohms.
b. Disconnect connector P23 (PPM) from the
main PCB, and check the continuity between
terminals 1 and 2, 3 and 4 of P23.
OK if
∞
ohms.
c. Insert P23 and P24 into the main PCB, turn
on the power switch and then check LD1
(red) on the power PCB.
OK if illuminated.
If LD1 is illuminated during the check in step
1 but it does not illuminate when P1 and P24
are connected, there is a malfunction of the
main PCB.
d. Check LD1 (orange) on the main PCB.
OK if illuminated.
Main PCB assembly 311H
3. If the work clamp pulse motor
moves slightly and “E300” is
displayed, there is a malfunction of
the encoder.
a. Check that connector P19 (P-ENC) is
inserted into the main PCB and that the color
matches.
b. Check the encoder input while referring to
“3-7. Input checking method”.
Pulse motor P assembly
Main PCB assembly 311H
4. If the work clamp pulse motor
does not move and “E300” is
displayed, there is a malfunction of
the pulse motor and cord.
a. Disconnect the main PCB connector P23
(PPM) and measure the resistance between
pins 1-2 and 3-4 of the cord connector.
OK if 2-3 ohms.
b. If step a (above) is OK, there is a malfunction
of the main PCB.
Pulse motor P assembly
Main PCB assembly 311H
2717B
2722B
2723B