11. LIST OF ERROR CODES
BAS-311H
145
Communication and memory-related errors
Code
Cause of error and remedy
E401
Communication error detected between the main P.C. board and the motor P.C. board when the power was
turned on.
Turn off the power, and then check that connector P1 on the panel P.C. board, connector P5 on the main P.C.
board and connectors P2 and P3 on the motor P.C. board are properly inserted.
E410
Communication error detected between the main P.C. board and the panel P.C. board.
Turn off the power, and then turn it back on again.
Turn off the power, and then check that connector P1 on the panel P.C. board, connector P5 on the main P.C.
board and connectors P2 and P3 on the motor P.C. board are properly inserted.
E411
Communication error detected between the main P.C. board and the motor P.C. board.
Turn off the power, and then turn it back on again.
Turn off the power, and then check that connector P1 on the panel P.C. board, connector P5 on the main P.C.
board and connectors P2 and P3 on the motor P.C. board are properly inserted.
E412
Communication error detected between the panel and the programmer.
Turn off the power, and then turn it back on again.
E420
No SD card is inserted.
Press the RESET key to clear the error.
Insert an SD card and then try again.
E421
The sewing data number is invalid or it has no corresponding data.
Press the RESET key to clear the error.
Check that data for this sewing data number is present on the SD card.
E422
An error occurred while reading from the SD card.
Check the data.
When reading BAS-311G user programs, first read the sewing data.
Press the RESET key to clear the error.
Check the data on the SD card.
E424
Insufficient free space on the SD card.
Press the RESET key to clear the error.
Use a different SD card.
E425
An error occurred while writing to the SD card.
Check the SD card.
The card may be write-protected.
Press the RESET key to clear the error.
Use the specified type of SD card.
E427
The program containing the specified cycle program has been cleared.
Press the RESET key to clear the error.
Redo the cycle program.
E430
Data cannot be backed up to the main P.C. board.
Turn off the power, and then turn it back on again.
E440
Data cannot be backed up to the main P.C. board.
Turn off the power, and then turn it back on again.
E450
Model selection cannot be read from the machine head memory.
Turn off the power, and then check that connector P16 on the main P.C. board is properly connected.
E452
Machine head memory is not connected.
Turn off the power, and then check that connector P16 on the main P.C. board is properly connected.
E453
Problem with data in machine head memory.
Turn off the power, and then turn it back on again.
E474
Internal memory is full and copying is not possible.
Press the RESET key to clear the error.
Clear the sewing data.