10. ELECTRIC MECHANISM
BAS-311H
129
Error status #2 Error code appears on the display when the power is turned on.
Probable causes
Check/repair/adjust
Parts to be replaced
1. If “E015” or “E016” is displayed,
there is a poor connection of the
STOP switch.
a. Check that the STOP switch is not stuck
down.
b. Check if there is a harness short-circuit.
c. Check that connector P9 (HEAD-SW) is
inserted into the main P.C. board.
STOP switch
2. If “E025” or “E035” is displayed,
the foot switch is still depressed.
a. Check if the foot switch is still depressed.
b. Check if there is a short-circuit in the
harness.
c. Check if connector P12 (PEDAL) is
connected to the motor PCB.
d. Reset the depression stroke for the foot
switch while referring to “8-25. Setting
method for standard depression stroke (Foot
switch)”.
*
For a two-pedal foot switch, the connector
for the main PCB will be P15 (PEDAL).
Treadle unit
two-pedal foot switch assembly
3. If “E055” is displayed, there is a
malfunction of the machine head
switch.
a. Check if the machine head switch is off.
b. Check if there is a broken wire in the
harness.
c. Check if connector P14 (HEAD-SW) is
connected to the main PCB.
Switch assembly machine head
4. If “E065” is displayed, one of the
keys on the operation panel is still
depressed.
a. Check that there is no incorrect sensitivity
when the surface of the panel sheet and the
keys are pressed.
b. Check that connector P3 (PANEL) is
connected to the motor PCB, and that
connector P1 (MAIN) is connected to the
panel PCB.
Operation panel assembly
Panel PCB assembly
Panel harness
5. If “E131” is displayed, there is a
poor connection of the
synchronizer.
Check that connector P11 (RESOLVER) and P1
(MT-ENC) is connected to the motor PCB, and
that connector P6 (MT-ENC) is connected to the
main PCB.
6. If “E401” and “E410” is displayed,
there is a connection fault between
the main PCB, motor PCB and the
panel PCB.
a. Check LD3 (green) on the main PCB.
OK if illuminated.
b. Check LD3 (green) on the motor PCB.
OK if illuminated.
c. Check that connector P5 (MOTOR) is
connected to the main PCB, and that
connector P2 (MAIN) is connected to the
motor PCB.
d. Check that connector P3 (PANEL) is
connected to the motor PCB, and that
connector P4 (MAIN) is connected to the
panel PCB.
e. Check if there is a broken wire in the
harness.
Main PCB assembly 311H
Motor PCB assembly
Panel PCB assembly
Connection harness
Panel harness
7. If “E450” or “E452” is displayed,
the machine head memory cannot
be recognized.
a. Check if connector P3 (HEAD-M) is
connected to the main PCB.
b. Check if there is a broken wire in the
harness.
8. If “E700” is displayed, the power
supply voltage is abnormally high.
a. Check that the power supply voltage at the
mains is at the specification voltage plus or
minus 10%.
b. See #1-2.
9. If “E705” is displayed, the power
supply voltage is abnormally low.
a. Check that the power supply voltage at the
mains is at the specification voltage plus or
minus 10%.
b. See #1-2.