Check the following after changing the intermittent stroke.
3383B
3382B
3239B
1. With the intermittent presser foot (1) lowered, turn the pulley (2) in the direction of the arrow to move the intermittent
presser foot (1) to its lowest position.
2. Check that the presser foot (1) does not touch the needle plate and that the presser bar clamp (3) does not touch the
presser bar bush (4).
<If they are touching>
Remove the motor cover (5).
Loosen the nut (6), and turn the bolt (7) until it is pressing against the intermittent drive lever (8), and then adjust until the
two points mentioned above are not touching.