3. FUNCTION SETTINGS
BAS-311H
20
Error processing settings
No.
Setting
range
Settings
Setting details
Initial
value
Specification
limits
Error release method when operation has stopped (Not reset during
initialization)
0
Press the RESET key on the operation panel to release errors.
1
Press the RESET key or the STOP key to release errors.
650 0-2
2
Press the RESET key or input a signal from the expansion input
switch (EXIN3) to release errors.
Cannot be set when memory switch No. 253 is set to "2".
0 None
Needle up stop when operation is paused
0
Stops at the needle down position when sewing is interrupted by the
STOP key.
1
Stops at the needle up position when sewing is interrupted by the
STOP key.
651 0-2
2
Stops at the needle up position after thread trimming when sewing is
interrupted by the STOP key.
(Thread trimming cannot be set when memory switch No. 652 is set
to "0".)
0 None
Thread trimming operation prevention when sewing is paused
OFF
Thread trimming is carried out when the pause is canceled.
652 ON/OFF
ON
Thread trimming is not carried out when the pause is canceled.
OFF None
Resuming sewing after sewing is paused
OFF STOP
switch
→
RESET key
→
▼
key
→
Sewing starts
653 ON/OFF
ON STOP
switch
→
RESET key
→
Sewing starts
OFF None
Disables needle up stop position monitoring sensor
OFF Sensor
enabled
(“UP” will be displayed)
655 ON/OFF
ON Sensor
disabled
OFF
(-3,-5)
ON
(-7)
None
Home position return when sewing is paused
OFF
Mechanism moves to home position and then moves to sewing start
position.
656 ON/OFF
ON
Mechanism steps back to the sewing start position along the sewing
path without moving to the home position.
OFF None
Time from error occurring to buzzer stopping
0
Buzzer does not stop.
657 0-30
2-30
Units (s), Increments of 2
0 None