Syntax:
show loop-detection
resource
The following table describes the output fields for this command.
Field definitions for the
show loop-detection resource
command
TABLE 10
Field
Description
alloc
Memory allocated
in-use
Memory in use
avail
Available memory
get-fail
The number of get requests that have failed
limit
The maximum memory allocation
get-mem
The number of get-memory requests
size
The size
init
The number of requests initiated
Displaying loop detection configuration status on an interface
Use the
show interface
command to display the status of loop detection configuration on a particular
interface.
Brocade# show interface ethernet 2/1
10GigabitEthernet2/1 is up, line protocol is up
Port up for 1 day 22 hours 43 minutes 5 seconds
Hardware is 10GigabitEthernet, address is 0000.0089.1100 (bia 0000.0089.1118)
Configured speed 10Gbit, actual 10Gbit, configured duplex fdx, actual fdx
Member of 9 L2 VLANs, port is tagged, port state is FORWARDING
BPDU guard is Disabled, ROOT protect is Disabled
Link Error Dampening is Disabled
STP configured to ON, priority is level0
Loop Detection is ENABLED
Flow Control is enabled
Mirror disabled, Monitor disabled
Member of active trunk ports 2/1,2/2, primary port
Member of configured trunk ports 2/1,2/2, primary port
No port name
IPG XGMII 96 bits-time
MTU 1500 bytes, encapsulation ethernet
ICL port for BH1 in cluster id 1
300 second input rate: 2064 bits/sec, 3 packets/sec, 0.00% utilization
300 second output rate: 768 bits/sec, 1 packets/sec, 0.00% utilization
171319 packets input, 12272674 bytes, 0 no buffer
Received 0 broadcasts, 63650 multicasts, 107669 unicasts
0 input errors, 0 CRC, 0 frame, 0 ignored
0 runts, 0 giants
51094 packets output, 3925313 bytes, 0 underruns
Transmitted 2 broadcasts, 42830 multicasts, 8262 unicasts
0 output errors, 0 collisions
Relay Agent Information option: Disabled
Displaying loop detection configuration status on an interface
84
FastIron Ethernet Switch Administration Guide
53-1003625-01