External USB Hotplug commands
TABLE 14
Command
Description
show files disk0
Displays the files in the external USB drive.
format disk0
Formats the external USB.
mount disk0
Mounts the filesystem in the external USB drive.
unmount disk0
Unmounts the filesystem of the external USB drive. This command is
required to safely plug out the USB, so that files are not lost or corrupted.
copy flash disk0 primary \
secondary
Copies the image binary stored in the primary or secondary partition of the
flash to a destination file in the external USB.
copy flash disk0 file
Copies any file from a source file in the system flash to an external USB
destination file.
copy disk0 license
Copies the license file present in the external USB drive to the system.
copy disk0 running-config
Copies the configuration file present on the external USB drive to the
system's running configuration.
copy disk0 startup-config
Copies the configuration file present on the external USB drive to the
system's startup configuration file.
Refer to the
FastIron Command Reference Guide
for details on using the External USB Hotplug
commands.
Commands
ip hitless-route-purge-timer
Configures the maximum time before stale routes are purged from the routing information base (RIB)
after a switchover, failover, or OS upgrade. The
no
form of this command sets the purge timer time to
its default value.
Syntax
ip hitless-route-purge-timer
seconds
no ip hitless-route-purge-timer
seconds
Parameters
seconds
Maximum time, in seconds, before stale routes are purged. The valid range is from 2 to 600.
The default is 45 seconds.
Modes
Global configuration
IPv4 address family configuration
Usage Guidelines
Under normal circumstances, you may not need to change the value of the route purge timer. If you
anticipate delay in learning the routes after switchover, you can configure a larger value for the route
purge timer.
Examples
The following example shows how to set the IPv4 hitless purge timer on the default VRF:
Brocade(config)# ip hitless-route-purge-timer 500
Commands
FastIron Ethernet Switch Administration Guide
137
53-1003625-01