To disable preemption on a Backup, enter commands such as the following.
device Router1(config)#interface ethernet 1/1/6
device Router1(config-if-1/1/6)#ip vrrp vrid 1
device Router1(config-if-1/1/6-vrid-1)#non-preempt-mode
Syntax:
[no] non-preempt-mode
The syntax is the same for VRRP and VRRP-E.
Changing the timer scale
NOTE
Changing the timer scale is supported for IPv4 VRRP v2, IPv4 VRRP-E v2, and IPv6 VRRP-E v3. It is not supported for IPv6
VRRP v3.
To achieve sub-second failover times, you can shorten the duration of all scale timers for VSRP, VRRP, and VRRP-E by adjusting the
timer scale. The
timerscale
is a value used by the software to calculate the timers. By default, the scale value is 1. If you increase the
timer scale, each timer’s value is divided by the scale value. Using the timer scale to adjust timer values enables you to easily change all
the timers while preserving the ratios among their values.
TABLE 104
Time scale values
Timer
Timer scale
Timer value
Hello interval
1
1 second
2
0.5 seconds
Dead interval
1
3 seconds
2
1.5 seconds
Backup Hello interval
1
60 seconds
2
30 seconds
Hold-down interval
1
2 seconds
2
1 second
If you configure the device to receive its timer values from the Master, the Backup also receives the timer scale value from the Master.
To change the timer scale, enter a command such as the following at the global CONFIG level of the CLI.
device(config)# scale-timer 2
This command changes the scale to 2. All VSRP, VRRP, and VRRP-E timer values will be divided by 2.
Syntax:
[no] scale-timer
num
The
num
variable specifies the multiplier. You can specify a timer scale from 1 through 10. However, Brocade recommends the timer
scale of 1 or 2 for VRRP and VRRP-E.
NOTE
Be cautious when configuring the
scale-timer
command in a VRRP or VRRP-E scaled environment. VSRP, VRRP, and VRRP-
E are time-sensitive protocols and system behavior cannot be predicted when the timers are scaled.
Additional VRRP and VRRP-E parameter configuration
FastIron Ethernet Switch Layer 3 Routing
53-1003627-04
535
Summary of Contents for FastIron SX 1600
Page 2: ...FastIron Ethernet Switch Layer 3 Routing 2 53 1003627 04 ...
Page 16: ...FastIron Ethernet Switch Layer 3 Routing 16 53 1003627 04 ...
Page 20: ...FastIron Ethernet Switch Layer 3 Routing 20 53 1003627 04 ...
Page 142: ...FastIron Ethernet Switch Layer 3 Routing 142 53 1003627 04 ...
Page 150: ...FastIron Ethernet Switch Layer 3 Routing 150 53 1003627 04 ...
Page 200: ...FastIron Ethernet Switch Layer 3 Routing 200 53 1003627 04 ...
Page 214: ...FastIron Ethernet Switch Layer 3 Routing 214 53 1003627 04 ...
Page 350: ...FastIron Ethernet Switch Layer 3 Routing 350 53 1003627 04 ...
Page 476: ...FastIron Ethernet Switch Layer 3 Routing 476 53 1003627 04 ...
Page 588: ...FastIron Ethernet Switch Layer 3 Routing 588 53 1003627 04 ...