36
en | Advanced Features
AutoDome Modular Camera System
F01U073308 | 3.0 | 2007.09
VG4-200, VG4-300, VG4-500i Series User’s Manual
Bosch Security Systems, Inc.
1.
Flash an OSD message (***ALARM 2***) on the monitor.
2.
Stop the AutoPan and move the camera to a saved position (Shot 5) viewing the fence.
3.
Turn on AutoTrack.
4.
Transmit a Bilinx signal to the head end system to trigger an alarm response.
The sequence to program this alarm rule example is as follows:
1.
Wire and set the alarm Input(s).
a.
Wire the motion detector to Input 1. (This circuit is normally open.)
b.
Wire the gate alarm contact to Input 5. (This circuit is normally closed.)
2.
From the Inputs Setup menu:
a.
Ensure Input 1 (the motion detector) is set to N.O. (This is the default setting for
Input 1.)
b.
Ensure Input 5 (the gate contact) is set to N.C.
3.
Set the alarm Outputs from the Outputs Setup menu:
a.
Set Output 5 to OSD.
b.
Set Output 6 to Transmit.
c.
Set Output 7 to Shot 5.
d.
Set Output 8 to AutoTrack.
4.
Set up the Alarm Rule (For this example use Rule 2). Select the alarm Inputs:
a.
From the Rule Setup menu select Rule 2.
b.
Set the first input to Alarm Input 1. (The motion detector.)
c.
Set the second input to Alarm Input 5. (The gate alarm contact.)
5.
Select the alarm Outputs:
a.
Set the first output to
OSD
.
b.
Set the second output to
Shot 5
viewing the fence.
c.
Set the third output to
AutoTrack
and select Latched.
d.
Set the fourth output to
Transmit
(a Bilinx signal to the headend).
6.
Enable the alarm Rule:
–
Highlight Enabled and select YES.
7.2
AutoTrack (500i Series Only)
The 500i Series AutoDome features enhanced AutoTrack software with more versatility and
smoother object tracking. AutoTrack is now able to continuously follow an object even if it
passes behind a Privacy Mask. When used with Virtual Mask, it is able to ignore predefined
areas of background motion.
–
To turn on AutoTrack, enter the keyboard command ON-78-ENTER.
–
In Pelco Mode, open the Main menu, select the Advanced menu, and then select
AutoTrack On.
i
NOTICE!
For instruction on wiring alarm and relay connections, see the AutoDome Modular
Camera System Installation Manual.
i
NOTICE!
For proper operation AutoTrack requires that the camera height be set in the
software. Open the Bosch Main menu, select the Advanced menu and select Camera Height to
enter the camera height.