ECODRIVE DKC02.1 Drive Controller
ECODRIVE DKC drive controllers
4-15
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
4.5 Switches
Switches S2, S3
The SERCOS address of the drive is determined by two decade switches.
The address can be a number ranging from 1 to 99.
Example:
switch position S3 = 9 (decadic value)
switch position S2 = 1 (digit value)
SERCOS address = 9 * 10 + 1 = 91
FP5105F5.fh5
ECODRIVE
Switch S3
Switch S2
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Setting the
SERCOS drive
address: 91
Fig. 4-19: Setting the drive address using the decade switch
Switch S4
The transmitter power and the data rate for the SERCOS interface are set
with the switch S4.
On delivery, the DKC is set to an average transmitter power (-4,5 dBm)
and the lowest data rate(2 Mbit/s).
The switches are in the OFF position if when the switch lever is facing the
rear (rear panel). Switch S4/1 is down (see marking on the unit).
Switches S2, S3
SERCOS address
Data rate, transmitter power
Switch position