ECODRIVE DKC02.1 Drive Controller
ECODRIVE DKC drive controllers
4-13
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
X5 connection for motor feedback
Maximum wire cross section which can be connected: 0.5 mm
2
INDRAMAT feedback cables are preferred for the connection.
Maximum cable length:
75 m
WARNING
No warranty!
Use of non-INDRAMAT cables voids the warranty for the
entire drive system.
⇒
Use only INDRAMAT cables!
X6 motor temperature, motor holding brake, 24V supply for the motor
holding brake
Maximum wire cross section that can be connected: 2.5 mm
2
The motors are equipped with a PTC resistor for monitoring the tem-
perature. The connection leads are contained in the motor power cable.
If the MKD motor is equipped with a holding brake, a DC +24 V (± 10 %)
voltage supply must be connected to X5/5.6.
The current consumption of the holding brake can be found in the motor
documentation ( see page 3 of the supplementary documentation), bea-
cuse the current consumption is dependent on the type of motor.
Note:
The holding brake of MKD motors is not intended to be a
service brake. It is worn out after approx. 20,000 revolutions
against the closed brake armature plate.
X7 motor power connection
Maximum wire cross section that can be connected: 4 mm
2
Maximum cable length:
75 m
Mount the entire shield of the motor power cable to the drive controller
using the screw (at the bottom of the unit, see Fig. 4-12).
WARNING
No warranty!
Use of non-INDRAMAT cables voids the warranty for the
entire drive system.
⇒
Use only INDRAMAT cables!
Feed back cable
Motor temperature monitor
Motor holding brake
Motor cable
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01