ECODRIVE DKC02.1 Drive Controller
ECODRIVE DKC drive controllers
4-3
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
Additional connection of the DC24 power supply
The DKC drives should be firmly connected to the DC24V power supply;
preferred method Fig. 4-4
They can also be connected to the DC24V power supply in a switchable
manner Fig. 4-5
X4/1
X4/4
power supply
DKC
24V
0V
V01DCC1P.fh5
Q2
Connecting additional DKC`s
L1
L2
L3
DC24V
Fig. 4-4:
Principle for connecting the DC24V control voltage by switching on the
power supply via Q2, preferred method
Rv
K1
X4/1
X4/4
24V
0V
DC24V
power supply
DKC
V02DCC1P.fh5
Connecting additional DKC x.1,DKC x.2
(max. 6 DKC + 6BZM01.1)
K1 closing delay >100 ms, DC1
≥
10A
Rv = 2,2
Ω
/ 5W (wire resistance)
S1 Cotact, DC1
≥
6 A
L1
L2
L3
S1
K1
Fig. 4-5:
Principle for connection the 24V via S1 with a starting current limiter
Preferred method:
The power supply is firmly
connected to the attached DKC
The power supply is connected
to the attached DKC in a
switchable manner
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01