ECODRIVE DKC02.1 Drive Controller
ECODRIVE DKC drive controllers
4-9
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
4.4 Electrical
connections
The electrical connections are described below:
•
grouped according to numbers of the supply terminal strip (for exam-
ple, X1, X2 etc.)
•
and then according to the functions.
Serial interface X1
Maximum wire cross section which can be connected: 2.5 mm
2
At present, the serial interface does not offer any functions for the user.
The interface only offers developers of the unit diagnostic possibilities.
X2 external measuring system
maximum cable cross section which can be connected: 0.5 mm
2
This interface offers the option of connecting an external measuring sys-
tem directly mounted to the machine element. The measuring system can
be a rotary encoder as well as a linear encoder. Measuring systems with
sinusoidal output signals and a signal level of 1Vss (Heidenhain voltage
interface) can be connected.
Output voltage X2/12:
DC +5 V (± 5%)
max. load on the output X2/12:
150 mA
approximate sinussoidal signals
The signal period supplied by the measuring system is sampled 2048
times.
Signal voltage:
A,B,R
1 Vss
max. frequency for measuring system signals:
A, B
200 kHz
max. cable length:
50 m
FP5102F5.fh5
X2
Voltage signal: A+, B+, R+
Voltage signal: A-, B-, R-
8, 6, 4
-
+
X2
2k
2k
36k5
36k5
7, 5, 3
X2
10, 11, 13, 14, 15
0 V
Fig. 4-14: Input circuit for the signals A,B,R
Supply voltage for an external
measuring system
Signal form
Resolution
Voltage signals
Cable length
Signal input circuit
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01