4-4
ECODRIVE DKC drive controllers
ECODRIVE DKC02.1 Drive Controller
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
Ambient and operating conditions
Selection lists are indicated for each motor controller documentation (see
page 3 of the supplementary documentation).
The selection lists data apply within the given ambient and installation
conditions (see).
Under different conditions, the continuous torque at standstill M
dN
and the
short-term operating torque
M
KB
are reduced according to the diagrams
(see Fig. 4-6). If deviating ambient temperatures and higher installation
altitudes occur simultaneously, both load factors must be multiplied.
DG0200D4.fh5
Load with higher
installation elevations
Load factor
Ambient temperature in °C
1000 2000 3000 4000 5000
0,6
0,8
1
0,6
0,8
1
40
45
50
55
0
0
Installation altitude meters
above sea level
Load factor
Load with higher
ambient temperatures
Fig. 4-6:
Load utilization as a value dependent upon ambient temperature and
installation altitude
Symbol
+55
internal blower cooling
DKC02.1-040-7-FW
T
UM,MAX
°C
+0...+45
T
UM
°C
-30...+85
T
L
°C
1000
m
95
%
25
g/m
3
IP20, as per EN 60529 = DIN VDE 0470-1-1992 (IEC 529-1989)
stationary use in control cabinets
4.4
m
kg
TB5103F5.fh5
Unit
Non-conductive dirt contamination, no condensation
The values indicated in the selection data
for M
DN
and M
KB
, drop in the range of +45
to +55°C by 2% per °C of rise in temperature.
Designation
Ambient and installation
conditions
Cooling the power section
Max. permissible ambient
temperature with reduced
nominal data
Permissible ambient temperature
with nominal data
Storage and transport
temperature
Max. installation elevation
with nominal data
Max. permissible relative humidity
Max. permissible absolute humidity
Degree of contamination
Protection category
Weight
Fig. 4-7: Ambient and operating cond itions
Ambient temperature and
installation altitude