Description
Symbol
Unit
HMU05.1N-
F0340-0820-
N-A4-D7-P
HMU05.1N-
F0430-1040-
N-A4-D7-P
HMU05.1N-
F0540-1300-
N-A4-D7-P
HMU05.1N-
F0680-1690-
N-A4-D7-P
Planned
Temperature increase for Q
min
and P
Diss_cont_F
ΔT
K
Less than 10
Pressure drop for Q
min
Δp
bar
0.6
1
1.3
Maximum allowed operating pres‐
sure
p
max
bar
2.00
Coolant channel volume
V
ch
ml
851
966
1024
tbd
Coolant channel material
Aluminum
Constant for determining pressure
drop
K
Δp
tbd
Air cooling data
Power dissipation ratio (air) with
continuous
current/continuous
power
P
Diss_cont_
A
W
1000.0
1200.0
1500.0
Ambient temperature range for
operation with nominal data
T
a_work
°C
0...40
Ambient temperature range for
operation with reduced nominal
data
T
a_work_red
°C
0...55
f
Ta
%/K
2.0
Volumetric capacity of forced cool‐
ing
V
m
3
/h
-
Minimum distance on the top of
the device
5)
d
top
mm
100
Minimum distance on the bottom
of the device
6)
d
bot
mm
100
Temperature increase with mini‐
mum distances d
bot
; d
top
; P
BD
ΔT
K
10
Last modification: 2016-06-17
1)
Also depending on firmware and control section; see parame‐
ter description "P‑0‑0001, Switching frequency of the power
output stage"; see "P-0-4058, Amplifier type data"; for supply
units the switching frequency is 4.2 kHz
2) 3)
Plus dissipation of braking resistor and control section; find in‐
terim values by interpolation to P_Diss_cont
4)
Plus dissipation of braking resistor and control section
5) 6)
See fig. "Air intake and air outlet at device"
Tab. 4-18:
HMU – cooling and power dissipation data
Bosch Rexroth AG
DOK-INDRV*-HXX05******-PR02-EN-P
92/407
Rexroth IndraDrive ML Drive Systems with HMU05
Combining the individual components