Data
Description
HML05.1W-D … -N-500-NNNN
Unit
021U-
N0254
018U-
N0306
014U-
N0392
009U-
N0490
009U-
N0616
007U-
N0771
006U-
N1002
004U-
N1185
Relative u
k
%
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Inductance
µH
3 × 21 3 × 18 3 × 14 3 × 9.1 3 × 8.9 3 × 7.0 3 × 5.6 3 × 4.5
Motor inductance in working point, typ.
µH
533
448
352
228
224
176
141
112
Working point 1: 2 kHz
clock frequency;
≤ 200 Hz rotary field
frequency
Nominal current
A
rms
254
306
392
490
616
771
1002
1185
Maximum phase-
phase capacitance
(motor cable)
nF
30
30
30
30
50
50
50
tbd
Maximum leakage
capacitance
nF
180
180
180
180
300
300
300
tbd
Working point 2: 4 kHz
clock frequency;
≤ 200 Hz rotary field
frequency
Nominal current
A
rms
254
306
392
490
546
632
775
1008
Maximum phase-
phase capacitance
(motor cable)
nF
20
20
20
20
30
30
30
tbd
Maximum leakage
capacitance
nF
120
120
120
120
180
180
180
tbd
Working point 3: 4 kHz
clock frequency;
≤ 400 Hz rotary field
frequency
Nominal current
A
rms
254
306
392
490
546
632
775
1008
Maximum phase-
phase capacitance
(motor cable)
nF
10
10
10
10
30
30
30
tbd
Maximum leakage
capacitance
nF
60
60
60
60
180
180
180
tbd
Stable inductance up to …
A
rms
314
377
454
582
727
915
1144
1488
Power dissipation
W
200
250
300
300
350
330
425
tbd
Voltage
V
3 × 500
Protection class
-
Class I
Degree of protection
-
IP00
Weight
kg
15
20
25
25
34
38
40
42
Tab. 8-49:
HML05, data
DOK-INDRV*-HXX05******-PR02-EN-P
Bosch Rexroth AG
229/407
Rexroth IndraDrive ML Drive Systems with HMU05
Cables, accessories, additional components