![Bosch Rexroth HMU05.1N Series Project Planning Manual Download Page 388](http://html.mh-extra.com/html/bosch/rexroth-hmu05-1n-series/rexroth-hmu05-1n-series_project-planning-manual_44851388.webp)
Size
Mains voltage
[VAC]
Chopper frequen‐
cy
[KHz]
THDi mains cur‐
rent
[%]
THDu mains voltage
[%]
Load
HMU05.1-F0340
400
4.2
3,087
3,152
Partial load 50%
HMU05.1-F0340
400
4.2
2,201
3,617
Nominal load
HMU05.1-F0340
400
4.2
1,983
3,824
Peak load
HMU05.1-F0340
500
4.2
3,265
2,870
Partial load 50%
HMU05.1-F0340
500
4.2
2,447
3,391
Nominal load
HMU05.1-F0340
500
4.2
2,112
3,554
Peak load
HMU05.1-F0430
400
4.2
5,076
3,511
Partial load 50%
HMU05.1-F0430
400
4.2
3,781
3,925
Nominal load
HMU05.1-F0430
400
4.2
3,440
3,948
Peak load
HMU05.1-F0430
500
4.2
4,911
3,338
Partial load 50%
HMU05.1-F0430
500
4.2
3,887
3,789
Nominal load
HMU05.1-F0430
500
4.2
3,772
3,892
Peak load
HMU05.1-F0540
400
4.2
3,175
3,334
Partial load 50%
HMU05.1-F0540
400
4.2
2,344
3,784
Nominal load
HMU05.1-F0540
400
4.2
2,080
3,869
Peak load
HMU05.1-F0540
500
4.2
3,352
3,121
Partial load 50%
HMU05.1-F0540
500
4.2
2,467
3,600
Nominal load
HMU05.1-F0540
500
4.2
2,378
3,729
Peak load
Tab. 11-10:
Total Harmonic Distortion (THD)
Bosch Rexroth AG
DOK-INDRV*-HXX05******-PR02-EN-P
386/407
Rexroth IndraDrive ML Drive Systems with HMU05
Appendix