PRAESENSA
Security | en
113
Bosch Security Systems B.V.
Configuration manual
2020-09 | V1.20 | PRAESENSA 1.20
7.1
System security
1.
Below
the Security page,
click
System security:
–
A new screen OMNEO system security appears where the:
–
OMNEO security username, and the
–
OMNEO passphrase can be viewed. These are both automatically created at 1
st
time /
initial
Logon the application, page 35.
2.
Both credentials
are used to create a secure connection between the PRAESENSA
system controller, the other network devices, PC and during upgrade of the PRAESENSA
network devices firmware.
3.
See
Change user name and passphrase, page 113 if you want to change the credentials.
4.
See 1
st
time / initial
Logon the application, page 35 for the automatically generated
secured credentials.
5.
See
Check/Upload the devices firmware, page 20 for a secured device firmware upload
connection.
6.
See
Backup and restore, page 103 for a (secured) backup and restore of your
configuration file.
7.1.1
Change user name and passphrase
The
security
user name and passphrase are automatically generated and created at 1
st
time /
initial logon. See
Logon the application, page 35, if required.
To change:
1.
Below
the System security page,
click
the + of the Change user name and passprase
category row:
–
Make sure that all configured network devices are connected. See also
disconnected devices, page 114.
2.
Click
the Generate (recommended) button which will generate a
new
User name and
Passphrase
or
enter
a
new
User name (minimum
5
and maximum
32
characters) and
Passphrase (minimum
8
and maximum
64
characters):
–
IMPORTANT
: for security reasons, both the User name and Passphrase need to be
changed.
3.
Click the Change button:
–
IMPORTANT
: Devices that get disconnected during the change process will still
receive the changes upon
reconnection
within one hour
. After one hour, remaining
devices must first be reset to factory default, and then reconnected. See
factory default devices, page 113.
Refer to
–
7.1.2
Reconnect factory default devices
Use this function if you want to securely reconnect one or more factory default devices. Notice
that reconnect a network device only works when it was already added in
To do so:
1.
Reset the disconnected device(s) to default by using the reset to default button:
–
For location of the reset to default button of the individual devices, see
options, page 43 > <device name> > Rear panel indicators and controls and/or the
PRAESENSA installation manual.