62
INSTALLER SETTINGS menu settings (for installers only)
6 720 617 763 (2008/09)
8.5.3 Parameters for solar optimisation
Solar optimisation is performed automatically
according to the available solar output. Calcula-
tion of the solar output requires specification of
the installed collector area, the collector type
and the climate zone in which the system is
installed.
Menu: Solar sys parameters > Solar optimisa-
tion
Use this menu to set the parameters for solar
optimisation.
•
Collector group 1 area
: Use this menu option
to set the installed collector area for collector
group 1.
•
Collector group 1 type
: Use this menu option
to set the installed collector type for collector
group 1.
•
Climate zone
: Use this menu option to set the
climate zone number for the geographical
region in which the system is located.
–
Find the location of your system on the cli-
mate zones map (
Æ
Fig. 24) and enter he
climate zone number.
–
If your location is not shown on the map,
leave the number as it is (default setting is
90).
•
Optimizing influence DHW
: This parameter
can also be set on the main menu under
Solar
.
A detailed description can be found on
page 47.
•
CH circuit optimizing influence
: This parame-
ter can also be set on on the main menu under
Solar
. A detailed description can be found on
page 47.
For menu structure and adjustment ranges
Æ
page 54.
Collector
type
Gross area per collector in
m
2
FK 210
2.1
FK 240
2.4
FK 260
2.6
VK 180
1.8
FKT-1
2.4
FKC-1
2.4
FKB-1
2.4
Tab. 22
Gross collector areas