INSTALLER SETTINGS menu settings (for installers only)
6 720 617 763 (2008/09)
8.1.1 INSTALLER SETTINGS: System configuration
8.1.2 INSTALLER SETTINGS: Heating parameters
8.1.3 INSTALLER SETTINGS: Solar system config
System configuration menu
structure
Default
setting
Setting range
Personal
setting
Description
starts on page
Start automatic system configu-
ration
No
No | Yes
Domestic hot water configura-
tion
Combi boiler No | Combi boiler | Cyl conn to
boiler | Cyl on IPM ident. 3 ... 10
CH system configuration
Unmixed
without IPM
No | Unmixed without IPM |
Unmixed with IPM | Mixed
DHW circulation pump
No
No | Present
ISM 1
No
No | Present
Tab. 13
Heating parameters menu
structure
Default
setting
Setting range
Personal set-
ting
Description
starts on page
Heating circuit type
Radiators
Foot point/End point | Underfloor
heating | Radiators | Convectors
Foot point
25 °C
10 °C ... 85 °C
°C
End point
75 °C
30 °C ... 85 °C
°C
Design flow temp.
75 °C
30 °C ... 85 °C
°C
Maximum CH flow temperature
80 °C
30 °C ... 85 °C
°C
Room influence
30%
0% ... 100%
%
Room influence enabled for lev-
els
Eco/Frost
Eco/Frost | Comfort/Eco/Frost
Room temperature offset
0.0 K
– 5.0 K ... 5.0 K
K
Heating off until lower level
reached
Yes
No | Yes
Heating off at outside tempera-
ture
20.0 °C
10.0 °C ... 25,0 °C, 99,0 °C
(= Function off)
°C
Freezing risk at outside tempera-
ture
3.0 °C
– 5.0 °C ... 10.0 °C
°C
Mixer running time
140 s
10 s ... 600 s
s
Minimum outside temperature
– 15 °C
– 30 °C ... 0 °C
°C
Building storage capacity
50%
0% ... 100%
%
Calibrate internal room temp
sensor
0.0 K
– 3.0 K ... 3.0 K
K
Tab. 14
Solar system config menu
structure
Default set-
ting
Setting range
Personal
setting
Description
starts on page
Solar sys option E Thermal disin-
fection
No
No | Yes
Tab. 15