E2600 DSA E-Series iSCSI Disk Arrays
Turning on the Power and Checking for Problems | en
67
Bosch Security Systems
Installation Manual
- | V2 | 2012.09
LEDs on the Controller Canister Main Faceplate
Figure 11.3
LEDs on the Controller Canister Main Faceplate
Normal operation – Drive I/O activity is
occurring.
Blinking
Off
Service action required – A fault condition
exists, and the drive is offline.
On
On
1
Ethernet Connector 1 Link Rate LED
2
Ethernet Connector 1 Link Active LED
3
Ethernet Connector 2 Link Rate LED
4
Ethernet Connector 1 Link Active LED
5
Host Link 1 Service Action Required LED
6
Host Link 1 Service Action Allowed LED
7
Host Link 2 Service Action Required LED
8
Host Link 2 Service Action Allowed LED
9
Battery Service Action Required LED
10
Battery Charging LED
11
Controller Service Action Allowed LED
12
Controller Service Action Required LED
13
Cache Active LED
14
Seven-Segment Tray ID
Table 11.4
LEDs on the Controller Canister Main Faceplate
Location
LED
Color
On
Off
1
Ethernet
Connector 1
Link Rate LED
Green
There is a 100BASE-T
rate.
There is a 10BASE-T rate.
2
Ethernet
Connector 1
Link Active LED
Green
The link is up (LED blinks
when there is activity).
The link is not active.
3
Ethernet
Connector 2
Link Rate LED
Green
There is a 100BASE-T
rate.
There is a 10BASE-T rate.
4
Ethernet
Connector 2
Link Active LED
Green
The link is up (the LED
blinks when there is
activity).
The link is not active.
Table 11.3
Drive State Represented by LEDs
Drive State
Drive Power LED
(Green)
Drive Service Action
Required LED (Amber)
Summary of Contents for DSA E Series
Page 1: ...E2600 DSA E Series iSCSI Disk Arrays en Installation Manual ...
Page 2: ......
Page 149: ......