20
en | Connections and settings
Digital Video Recorder
F01U | 2.0 | 2008.12
User Manual
Bosch Security Systems
3.8
Connecting a RS-422/485 device
Use this port to connect PTZ cameras.
Connect the PTZ serial communication lines to the RS-422/485 terminal.
Notes:
• When connecting lines, connect the TX- of the DVR to RX- of the PTZ
unit and TX+ of the DVR to RX+ of the PTZ unit correctly.
• Recommended initial data are 9600 Baud Rate, 8 Data bits, 1 Stop bit
and No parity.
• When connecting PTZ cameras to DVRs it is necessary to set the setup
menu for this unit according to the RS-485 settings of the camera and
DVRs.
Figure 3.2
RS-422/485 connections
RS-422/485 Terminal
Description
TX- (DATA -)
Data Transmission
TX+ (DATA +)
Data Transmission
RX- (DATA -)
Data Reception
RX+ (DATA +)
Data Reception
GND
Shield
Table 3.1
RS-422-485 connections