Sequence Mon. A
Figure 6.27: Camera sequence setup
Setup a camera sequence as follows:
–
Enable sequence: Select check box to enable sequence.
The sequence will automatically start when the system is in live view. To stop and start a
camera sequence on Monitor A, use the Sequence on/off option on the Quick menu
(right-click mouse button) or click the sequence button on the remote control or front
panel (only DIVAR AN 5000 ).
–
Interval: This value ranges from 5 (default) to 120 seconds.
–
Split: Choose here which view combinations are displayed (1, 4, 8, 9 and/or 16 windows)
and which combination of cameras to use in the camera sequence. If required, use the
Add, Delete, Move up or Move down buttons to add or delete views, or to adjust the
order of view settings.
For example: Choose camera 1 and 2 in View 1, plus cameras 1 to 8 in View 9 – the
sequence will sequence between a single window and 9-window display.
Note 1: Use Default to select all camera sequences for all possible view types (the Enable
sequence will be deactivated, and the Interval will be reset to 5 seconds).
Note 2: An enabled alarm/event will override a sequence and briefly display the event before
returning to the sequence.
6.10.1
DIVAR AN 3000 / DIVAR AN 5000
Configuration | en
69
Bosch Security Systems
Operations Manual
2015.10 | v2.3 | AM18-Q0669