Connecting the alarm output
Danger!
Electrical voltage
Risk of electric shock and damage to the unit.
The contacts must not be used at AC line voltages.
The alarm output relays respond to input alarms and triggers. Only connect resistive loads to
the alarm output relays. To avoid overloading, always make sure the relay has the following
specifications.
Relay Specification
Model
JRC-27F
Touch material
Silver
Rating (resistance load)
Rated switch capacity
30 VDC, 2 A; 125 VAC, 1 A
Maximum switch power
125 VA, 160 W
Maximum switch voltage
250 VAC, 220 VDC
Maximum switch current
1 A
Power supply
DIVAR AN 3000
DC power is supplied from an AC/DC power supply unit delivered with the unit. The unit has
its own on/off switch to turn power supply off and on.
Specifications:
–
External power supply unit:
–
AC input: 100-240 VAC; 1.7 A; 50/60 Hz
–
DC output: 12 VDC; 5 A
–
DIVAR power input: 12 VDC; 3.5 A
DIVAR AN 5000
Power is supplied from an AC power supply. The unit has its own on/off switch to turn power
supply off and on.
Specifications:
Power supply: AC input: 100-240 VAC; 1.7 A; 50/60 Hz
5.10.2
5.11
DIVAR AN 3000 / DIVAR AN 5000
Hardware setup | en
35
Bosch Security Systems
Operations Manual
2015.10 | v2.3 | AM18-Q0669