Maintenance SCT 141x | SCT / CCT / EL | 49
en
Checklist for SCT 141x and SCT 410
Setting
Target value
Pitch angle
+/- 0.5°
Roll angle
+/- 0.3°
Rotation around vertical axis for laser module
+/- 0.15°
Alignment of the measurement boards
+/- 1.5 mm
Lateral positioning of the test boards
+/- 4 mm
Height adjustment
+/- 800 - 1500 mm
Accuracy of the height adjustment
+/- 5 mm
Yaw angle / parallelism of upper and lower cross beams
+/- 0.2°
Maintenance of entire unit
Yes
No
Test result / comments
Roll angle and pitch angle of the precision measuring bar che-
cked?
Roll angle spirit level on L-bracket checked?
Pitch angle spirit angle on L-bracket checked?
Pitch angle on the slides checked?
Yaw angle / parallelism of upper and lower cross beams che-
cked?
Component maintenance
Yes
No
Test result / comments
P-Assist S5 1 690 381 124 / 1 690 381 174 checked?
Laser beam length of P-Assist S5 checked?
Laser beam thickness of P-Assist S5 checked?
Play of the P-Assist S5 checked?
P-Assist S5 in laser mount A checked?
P-Assist S5 in laser mount B checked?
P-Assist S5 for rotation checked?
Precision measuring bar checked?
Laser mount checked?
Slides on the precision measuring bar checked?
Post SCT 410 checked?
Slide on the post SCT 410 checked?
Base plate SCT 410 checked?
Mounting bracket and clamp for SCT 410 checked?
Calibration targets checked?
Slide for large calibration targets and star handle shaft che-
cked?
Setting of offset indicator for measurement bay checked?
Setting of mount 1 to 2 and to the lower offset indicator che-
cked?
Setting of mount 1 to 2 and to the upper offset indicator che-
cked?
End stop and sealing wax checked?
Precision measuring bar - retainer on mount 1 and 2 has no da-
mage, moves easily and has no play?
Date
Tester's name
Company
Test location
Signature