![Bosch CCT 3 Series Test Instructions Download Page 36](http://html.mh-extra.com/html/bosch/cct-3-series/cct-3-series_test-instructions_50401036.webp)
en
1 690 386 058
2018-01-30
|
Robert Bosch GmbH
36 | SCT / CCT / EL | Checking standard components
en
=1000 mm
1
2
2
2
3
4512001-19_shd
4
2
3
4
2
1000 mm
1000 mm
Abb. 19: Test boards 1 and 2 aligned with the 0-point
1 Reference laser
2 Laser beam of reference laser
3 Test board 1
4 Test board 2
8.
Remove the reference laser.
9.
Fasten the P-Assist S5 (Abb. 20, item 1) to laser
mount A on the L-bracket and rotate counterclockwi-
se as far as possible.
The laser beam (Abb. 20, item 2) of the P-Assist
S5 marks both test boards.
1
3
4512001-32_shd
4
2
2
2
X1
2
4
3
X2
2
=1000 mm
1000 mm
1000 mm
Abb. 20: Laser beam of the P-Assist S5 on test boards 1 and 2
1 P-Assist S5
2 Laser beam of the P-Assist S5
3 Test board 1
4 Test board 2
X1 Distance between the 0-point on test board 1 and the laser
beam of the P-Assist S5
X2 Distance between the 0-point on test board 2 and the laser
beam of the P-Assist S5
10.
Measure the distance X1 (Abb. 20, item X1) between
the 0-point on test board 1 and the laser line of the
P-Assist S5.
11.
Measure the distance X2 (Abb. 20, item X2) between
the 0-point on test board 2 and the laser line of the
P-Assist S5.
12.
Add the distances X1 and X2.
The sum of the distances X1 and X2 is the test re-
sult.
!
The test result must not be greater than 5.3 mm.
Measure in case of impermissible observational error
¶
Replace the P-Assist S5.