10.
Check the difference between the 0-point on the
test board and the reflected laser beam.
11.
Repeat steps 4 to 8 using positions B (scale mark
15) and C (scale mark 5).
A
B
C
1
2
3
4
4512001-31_shd
Abb. 44: Repeating the test at positions B and C
1 Transport position
2 Test board
3 P-Assist S5
4 Reference board
!
Maximum permissible difference between laser be-
ams on the test board (2): 5.3 mm.
Measure in case of impermissible observational error
¶
Replace both reference boards.
5.2.7
Checking the alignment lasers
1.
Check that the batteries are functioning.
2.
Inspect the alignment laser for visible flaws and dirt.
3.
Clean the contact surfaces.
4.
Grease the socket pin.
4512001-34_shd
Abb. 45: Alignment laser, front
4512001-33_shd
Abb. 46: Alignment laser, rear
5.
Move the adjustment beam to the transport position
(Abb. 47, item 1).
6.
Mount the alignment lasers vertically at the left and
right on the adjustment beam (Abb. 47, item 2) and
level using the 2-minute spirit level.
7.
.Switch on the alignment lasers.
8.
Align the test boards (Abb. 47, item 3) with the
0-point at a distance of 3000 mm and fasten in
place.