4.2.4
Special Preset Commands
Some
Pelco
mode preset commands have a special meaning and override the normal Pelco
preset function as follows:
Preset Command
Description
33-PRESET
Pans the AutoDome 180° (Flip).
34-PRESET
Goes to
Zero Pan
(original home position).
80-PRESET
Toggles the
Synchronization Mode
between Line Lock and Internal
(Pelco Frame Scan). This command is available if commands are
unlocked using the Main menu.
81-PRESET
Initiates
Preset Tour 1
.
82-PRESET
Initiates
Preset Tour 2
.
92-PRESET
Sets the
Left
pan limit for an AutoScan with
Limit Stops
enabled.
93-PRESET
Sets the
Right
pan limit for an AutoScan with
Limit Stops
enabled.
94-PRESET
Initiates a
Preset Tour
.
95-PRESET
Enables or disables
Limit Stops
in the
Setup Menu
for AutoScan.
Invokes the Pelco main
Setup Menu
when pressed for 2 seconds.
96-PRESET
Stops a scan.
97-PRESET
Initiates FastAddress (Pelco Random Scan).
98-PRESET
Toggles the
Synch. Mode
between
Line Lock
and
Internal
(Pelco Frame
Scan). This command is available only for two (2) minutes after the
power is applied and then reverts to normal preset functionality.
99-PRESET
Starts an AutoScan
NOTICE!
Some Pelco controllers do not support all the preset command numbers. Consult the specific
Pelco controller's documentation for supported preset commands.