18
en | On-Screen Display Menu Navigation
AutoDome 600 Series Analog PTZ Camera
F.01U.270.005 | 2.0 | 2012.06
User Manual
Bosch Security Systems, Inc.
2.7
Alarm I/O Setup
The
Alarm Setup Menu
provides access to the
Alarm I/O Setup Menu
to establish the alarm
inputs and outputs and to configure alarm rules.
Alarm Setup Menu Choices:
Alarm I/O Setup
Inputs Setup
Exit...
Exit...
Inputs Setup...
1. Alarm Input 1
N.C.S.
Physical
Input 1-7
Outputs Setup...
2. Alarm Input 2
N.O.S.
Rule Setup...
3. Alarm Input 3
N.O.
Restore Defaults...
4. Alarm Input 4
N.C.
5. Alarm Input 5
N.O.
6. Alarm Input 6
N.C.
7. Alarm Input 7
N.O.
8. NONE
9. NONE
Physical
Output 9-12
10. NONE
11. NONE
12. NONE
Focus / Iris: Select Type
Focus / Iris: Select
Right / Left: Select Mode
Menu
Description
Sub-menu / Description
Default
Setting
Exit
Saves and exits the menu.
Inputs Setup
Defines physical inputs or events and
commands that can be used in a rule.
There are twelve (12) alarm inputs
available.
Inputs 1-7
Defines the type of physical input.
N.O.
: Normally open dry contact.
N.C.
: Normally closed dry contact.
N.C.S.
: Normally closed supervised contact.
N.O.S.
: Normally open supervised contact.
N.O.
Inputs 8-12
Defines input commands that can be
used in a rule. Command inputs can also
be customized by using non-assigned
keyboard command numbers.
NONE
: No command defined.
Aux On
: Responds to a standard or custom
keyboard
ON
(1-99) command.
Aux Off
: Responds to a standard or custom
keyboard
OFF
(1-99) command.
Shot
: Responds to a Preset shot or scene from
1-99.
AutoTrack
: Triggers an alarm when set to ON.
Motion Detection
: Triggers an alarm when set
to
ON.
NONE
NOTICE!
Alarm inputs 1 and 2 provide tamper detection, if programmed as supervised, for breaks or
shorts in an alarm circuit. See the
VG5 AutoDome Installation Manual
for wiring instructions.