166
en | Card Reader Keypad Functions
Access Easy Controller
Ver 2.0.0 | 2006.07
Hardware Manual
Bosch Security Systems
S-Series reader LED indicators
*Slow flashing is at around 1 sec ON then 1 sec OFF interval; whereas normal flashing is at ½ secinterval.
The LED besides being used to indicate an alarm condition in the zone is also used during the
Arming process.
When you arm the Alarm Zone, the LED will flash for the duration as depicted in the Arm Delay
field of that particular Alarm Zone. We provide a few example below for further understand-
ing.
Configuration in the AEC.
X
Input Points #1, 2, 3, and 4 are grouped as Alarm Zone #1.
X
Arm Delay = 15 seconds.
X
Alarm Delay = 0 seconds
X
Reader #4 is the Arm/Disarm Reader for Alarm Zone #1.
X
Some cards are given the access rights to arm/disarm Alarm Zone #1. No PIN code
required.
Arming an Alarm Zone
Example 1 - All Input Points are in the Normal state.
1.
LED has a stable green light.
2.
Press 0 key and Present the arming card to Reader #4.
S-Series reader
Status LED
(Tri-color)
Armed
LED
Alarm
LED
Internal
Buzzer
Armed
The zone is Armed
RED
RED
OFF
OFF
Ready/Disarmed
All input points in the zone
are in normal state and ready
to be armed.
GREEN
OFF
OFF
OFF
Not Ready(before Armed)
One or more input points is
not in the normal state and
not ready for arming.
GREEN/
RED Flashing
RED
Flashing
OFF
OFF
Armed Partial (Some input
Bypass)
Zone failed to be armed due
to certain input point(s) are
not ready.
AMBER/
RED Flashing
RED
Flashing
OFF
OFF
Armed Fail (All input Bypass)
Zone failed to be armed due
to all inputs are not ready.
RED
RED Flashing OFF
OFF
Alarm
Zone is armed and one or
more input point is in alarm
state.
RED
RED Flashing RED
Flashing
(slow*)
Beeping
ON/OFF
at 1 Sec
interval