111
Post Alarm (sec)
It means the time of recording after user press [Rec] button and can be set Latched or max. 60 seconds.
<Note>
1.
In case of set ‘No Rec.’ in Schedule Rec., it records as a set of Pre Alarm. While Schedule
Recording, it records Pre Alarm section in speed(ips) of a set Schedule Rec.
2.
When Post Alarm is set to Latched, it maintains user recording continuously till the stop
pressing [REC] button by user.
16.2.
Alarm Action setup (Alarm Act.)
Alarm action is can be divided into Event alarm action & System alarm action.
Event Alarm action
It means Relay, E-mail, Buzzer, Pop-up, OSD display, PTZ preset operates by Motion Detection, Sensor
input, Text input of event alarm.
System Alarm action
It means alarm that affects to opearation of DVR occurred in DVR.
There are HDD fail. HDD almost full, Fan fail, Password fail, WRS Reg fail, HDD Write Fail, S.M.A.R.T
and does not affecs to Recording condtion.
According each Time schedule, it sets Relay action. It sets to 5 different time period, Full Time, Weekday
(Day), Weekday (Night), Weekend (Day), Weekend (Night). After Schedule setup, it sets Relay, Buzzer,
Email etc to operate Alarm action.
Summary of Contents for BL-32960M
Page 1: ...DVR Installation User s Guide BL 1680A BL 32960M v 1 4...
Page 24: ...24 7 eDVR configuration 7 1 Basic configuration 7 2 Advanced configuration...
Page 25: ...25 7 3 External storage Back up configuration 7 4 Internet Intranet configuration...
Page 35: ...35 Note Wire Handling on page 27...
Page 136: ...136 Save Settings Save present set value to USB device...
Page 181: ...181 18 3 16 Input Set sensor type user wants NC Normal Close NO Normal Open Off 18 3 17 Relay...
Page 195: ...195 APPENDIX APPENDIX APPENDIX...
Page 197: ...197...
Page 201: ...201...
Page 205: ...205 13 Install HDD RACK 14 Clise the case and drive a screw...
Page 223: ...223...