Blue Box 2
- compressors over-temperature protection on discharge gas with liquid injection
- chilled water temperature probe (at evaporator inlet)
- freeze protection probe at the evaporator outlet
- compressor over-temperature protection
- fan over-temperature protection
TESTING
The units are subjected to a dry run in the factory and supplied complete with oil and refrigerant.
KAPPA V SR UNIT VERSIONS
KAPPA V SR /HP: reverse cycle heat pump
In addition to the components of version KAPPA V SR, this unit includes:
- Refrigerant circuit: 4-way reversing valve, suction separator, liquid receiver, second thermostatic expansion
valve.
- Electrical panel: Microprocessor enabled for summer/winter changeover and automatic defrost,
HYDRAULIC MODULE OPTIONS
KAPPA V SR 2PS: unit with storage tank and pumps.
In addition to the components of version KAPPA V SR this unit includes:
insulated storage tank; run and standby circulating pumps, with automatic changeover by time or fault.
Expansion tank, check valves and gate valves.
Version ST is available in the following additional four configurations:
- ST 1PS : with 1 pump and a tank;
- ST 2P : with 2 pumps without a tank;
- ST S : with tank without pumps;
- ST 1P : with 1 pump without a tank.
ACCESSORY VERSIONS
KAPPA V SR /DC: unit with heat recovery condenser.
In addition to the components of version KAPPA V SR this unit includes for each compressor a 100% heat
recovery condenser for the production of hot water. The microprocessor automatically controls the water tempe-
rature and the heat recovery safety switch.
KAPPA V SR /LN: low noise unit
In addition to the components of version KAPPA V SR this unit includes:
compressors located in a sound absorbing enclosure of painted galvanized steel, internally lined with sound
absorption material having an intermediate layer of high acoustic impedance material.
REFRIGERANT CIRCUIT ACCESSORIES:
- Desuperheaters
The desuperheater heat exchanger is arranged in series with the condensing coil. It is also available in a
heat pump configuration. In this case a shut-off valve must be fitted on the water recovery circuit, to be
closed during heat pump mode operation, as described in the manual.
- Pressure gauges.
Available on all models. Suction and discharge pressure values, read by transducers that relay the results to
the controller display, are already displayed as standard on all models.
Summary of Contents for KAPPA V SR
Page 2: ......
Page 6: ......
Page 29: ...Blue Box 23 HYDRAULIC CIRCUIT DIAGRAM VERSION KAPPA V SR ST 2PS...
Page 40: ...Blue Box 34 ELECTRICAL PANEL LAY OUT MODELS 65 2 100 2...
Page 69: ...Blue Box 63 KAPPA V SR REFRIGERANT CIRCUIT...
Page 70: ...Blue Box 64 KAPPA V SR HP REFRIGERANT CIRCUIT...
Page 71: ...Blue Box 65 KAPPA V SR DC REFRIGERANT CIRCUIT...
Page 80: ...Blue Box 74...
Page 81: ......