Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 29 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PowerTruck_CANOpen_UM_REV1.5
g)
Set startup red LEDs backlight brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
07h
Sub index
Byte 4
XXh
Intensity 00h-3Fh
à
0-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 07 30 00 00 00
Brightness = 75%
Keypad reply
595
Std
60 03 20 07 00 00 00 00
h)
Set startup blue LEDs backlight brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
08h
Sub index
Byte 4
XXh
Intensity 00h-3Fh
à
0-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 08 08 00 00 00
Brightness = 12,5%
Keypad reply
595
Std
60 03 20 08 00 00 00 00