Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 5 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PowerTruck_CANOpen_UM_REV1.5
3.
Default settings
Setting
Default state or level
How to change
Baud Rate
125 kbit/s
Object 2010h
CANopen Node ID
15h
Object 2013h
CANopen Node State
Stop
NMT message start CANopen node
LED Indicator
Brightness
3Fh (Maximum brightness 3Fh)
Object 2003h
Backlight Brightness
00h (OFF)
Object 2003h
Periodic Message
Transmission
Disable
Object 1800h
Heartbeat Message
Disable
Object 1017h
Boot-up service
Active
Object 2011h
NMT MESSAGES
The Network Management messages follow a master-slave structure. Through NMT services,
CANopen devices are initialized, started, reset or stopped. All CANopen devices are regarded as
NMT slaves. NMT messages have CAN-ID always equal to 00h.
4.
Start CANopen node (keypad activation message)
Identifier
00h
Byte 0
01h
Start CANopen node
Byte 1
XXh
Keypad CAN ID
00h: start all the keypads
15h: start the keypad with CAN ID =
15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
01
5
5.
Enter pre-operational
Identifier
00h
Byte 0
80h
Enter pre-operational
Byte 1
XXh
Keypad CAN ID
00h: enter all the keypads
15h: enter the keypad with CAN ID =
15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
80 15