Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 31 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PowerTruck_CANOpen_UM_REV1.5
34.
Object 2012h: Set device active on startup
If keypad is active on startup don’t need the Start CANopen command from host.
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
12h
CAN Object 2012h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Not active
01h: Active
Byte 5,7
00h
Not used
Example:
Direction
Identifier Format Message
Data
To Keypad
615
Std
2F 12 20 00 01 00 00 00 Set device active on startup
Keypad reply
595
Std
60 12 20 00 00 00 00 00
35.
Object 2013h: Set CANopen node ID
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
13h
CAN Object 2013h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
XX: New node id (00h-7Fh),
default 15h
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 13 20 00 18 00 00 00
Set CANopen node ID = 18h
Keypad reply
598
Std
60 13 20 00 00 00 00 00
36.
Object 2014h: Set startup LED show
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
14h
CAN Object 2014h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Not active
01h: Active
Byte 5,7
00h
Not used
Example:
Direction
Identifier Format Message
Data
To Keypad
615
Std
2F 14 20 00 00 00 00 00
Startup LED show not active
Keypad reply
595
Std
60 14 20 00 00 00 00 00