background image

©

Copyright 2006. Black Box Corporation. All rights reserved.

Summary of Contents for LPB201A

Page 1: ... Copyright 2006 Black Box Corporation All rights reserved ...

Page 2: ... 24 hours a day 7 days a week Call or fax Mailing address 1000 Park Drive Lawrence PA15055 1018 Web site E mail toll free 877 877 BBOX 724 746 5500 FREE 724 746 5500 724 746 0746 Black Box Corporation www blackbox com info blackbox com 24 Port 1000BASE TX L2 Managed PoE Switch With 2 SFP Dual Media Ports ...

Page 3: ......

Page 4: ...ed by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le présent appareil numérique n émet pas de bruits radio électriques dépassant les limites applicables aux appareils numériques de...

Page 5: ...uipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufasu otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo deoperación o como se indique en el aparato 12 Precaución debe ser tomada de tal manera que la tierra fisica y la po...

Page 6: ... NT are registered trademarks of Microsoft Corporation Netscape is a registered trademark of Netscape Communications Corporation Telnet is a trademark of Telnet Communications Inc UNIX is a registered trademark of UNIX System Laboratories Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners NOTE The 24 Port 10 100BASE TX L2 Managed PoE Switc...

Page 7: ... the Management Agent 21 3 4 1 Via the Serial RS 232 Console Port 22 3 4 2 Via the Ethernet Port 24 3 5 IP Address Assignment 25 3 5 1 IP Address 25 3 5 2 Subnet Mask 26 3 5 3 Default Gateway 27 3 5 4 DNS 27 3 6 Typical Applications 27 3 6 1 Remote Site Central Site Connection 28 3 6 2 Peer to Peer Network Connection 29 3 6 3 Office Network Connection 30 4 Web Based Management 31 4 1 Home Overview...

Page 8: ...4 MAC Alias 60 4 10 GVRP Configuration 61 4 10 1 GVRP Config 62 4 10 2 GVRP Counter 64 4 10 3 GVRP Group Information 64 4 11 STP Configuration 65 4 11 1 STP Status 65 4 11 2 STP Configuration 66 4 11 3 STP Port Configuration 67 4 12 Trunking Configuration 70 4 12 1 Port Setting Status 71 4 12 2 Aggregator View 72 4 12 3 LACP System Config 73 4 13 802 1x Configuration 73 4 13 1 802 1x State Setting...

Page 9: ...18 5 T Type ToS 91 4 18 6 R Type ToS 91 4 18 7 M Type ToS 92 4 18 8 DSCP Setting 93 4 19 Diagnostics 93 4 19 1 Diag 93 4 19 2 Loopback Test 93 4 19 3 Ping Test 94 4 20 TFTP Server 94 4 21 Log 94 4 22 Firmware Upgrade 95 4 23 Reboot 95 4 24 Logout 96 5 CLI Management 97 5 1 Login 97 5 2 Commands 97 5 2 1 Global CLI Commands 98 5 2 2 Local CLI Commands 103 6 Troubleshooting 179 6 1 Resolving a No Li...

Page 10: ...800 pps at 100 Mbps 14 880 pps at 10 Mbps MAC Address and Self Learning 8K MAC address 256 VLAN table entries 256 IP multicast table entries Buffer Memory Embedded frame buffer 256 KB control memory 128 KB Flow Control IEEE802 3x compliant for full duplex Backpressure flow control for half duplex Cable Type and Maximum Length Twisted pair CAT5 UTP cable up to 328 feet 100 m ports 1 8 Single mode s...

Page 11: ...ss of Service CoS by the IEEE802 1p standard classification of packet priority can be based on either a VLAN tag on a packet or user defined per port QoS Two queues per port IP ToS classification TCP UDP port classification IP DiffServe classification Port Security Limited number of MAC addresses learned per port static MAC addresses in the filtering table stay in the filtering table Internetworki...

Page 12: ...e DB9 connector pin out Function Pin Carrier CD 1 Receive Data RXD 2 Transmit Data TXD 3 Data Terminal Ready DTR 4 Signal Ground GND 5 Data Set Ready DSR 6 Request To Send RTS 7 Clear To Send CTS 8 Table 1 2 shows the pin out for the null modem cable Table 1 2 Null modem cable pin out Signal Pin Pin Signal CD DTR DSR CD DTR 4 6 DSR RXD 2 3 TXD TXD 3 2 RXD GND 5 5 GND RTS 7 8 CTS CTS 8 7 RTS Not us...

Page 13: ...ast Storm Control IEEE 802 1q in q nested VLAN support full duplex flow control IEEE 802 3x and half duplex backpressure and extensive front panel diagnostic LEDs Software features include port status and configuration per port traffic monitoring counters system information snapshot upon login port mirroring static trunk and 802 1q VLAN The switch also supports user management and limits three use...

Page 14: ... Network Monitoring and is a branch of the SNMP MIB The device supports MIB 2 RFC 1213 Bridge MIB RFC 1493 RMON MIB RFC 1757 statistics Group1 2 3 and 9 Ethernet like MIB RFC 1643 and Ethernet MIB RFC 1643 IGMP Snooping Supports IGMP version 2 RFC 2236 IGMP snooping establishes the multicast groups that forward multicast packets to the member ports This avoids wasting the bandwidth while IP multic...

Page 15: ...LEDs ports 1 24 LEDSET set on ACT active mode Blinks when any traffic is present LEDSET set on FDX full duplex mode Lights when full duplex mode is active Blinks when any collision is present LEDSET on SPD speed mode Lights when 100 Mbps speed is active Off when 10 Mbps speed is active g SFP Fiber ACT FDX SPD LEDs ports 25 26 LEDSET set on ACT active mode Blinks when any traffic is present LEDSET ...

Page 16: ...ection is not good i Fast Ethernet ports 24 10 100 Mbps auto sensing ports j SFP Fiber FX LEDs Lights when Fiber port is active Off when TP port is active k SFP Fiber Gigabit TP Ports SFP fiber port module slots Gigabit TP ports l LEDSET button Selects the LEDSET mode Reset button Resets the management system The switch s rear panel is shown in Figure 2 2 The numbered components in the figure are ...

Page 17: ...eiver modules are available These modules are described below and shown in Figures 2 3 and 2 4 Small Form Factor Pluggable SFP Optical Transceiver Multimode 850 nm 550 m LGB200C MLC Small Form Factor Pluggable SFP Optical Transceiver Single Mode 1310 nm 10 km LGB200C SLC10 Small Form Factor Pluggable SFP Optical Transceiver Single Mode 1550 nm 30 km LGB200C SLC30 Small Form Factor Pluggable SFP Op...

Page 18: ... 1 Installing the optional SFP fiber transceiver module Connecting the SFP Module to the Chassis The optional SFP modules are hot swappable so you can plug or unplug them before or after powering on the switch 1 Verify that the SFP module is the right model and conforms to the chassis 2 Slide the module into the slot Make sure that the module is properly seated against the slot socket connector 3 ...

Page 19: ... a workstation or server or fiber transceiver module is plugged into the switch or not when powered on After the power is on all LED indicators will light up immediately and then all LEDs except the power LED go off This resets the system Firmware Loading After resetting the boot loader will load the firmware into the memory This will take about 30 seconds then all switch LEDs will flash once as t...

Page 20: ...m single strand single mode Gigabit fiber with BiDi LC1550 nm SFP module LGB205C 3 3 3 SWITCH CASCADING Theoretically the switch partitions the collision domain for each port in switch cascading so that you may up link an unlimited number of switches In practice the network extension cascading levels and overall diameter must comply with the IEEE 802 3 802 3u 802 3z and other 802 1 series protocol...

Page 21: ...ology in Deployment A hierarchical network with minimum switch levels may reduce the timing delay between the server and the client station This approach will minimize the number of switches in any one path It will also lower the network loop possibility and will improve network efficiency If more than two switches are connected in the same network select one switch as the Level 1 switch and conne...

Page 22: ...ation Figures 3 4 and 3 5 show a port based VLAN and Figure 3 6 shows an attribute based VLAN 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports VLAN 1 VLAN 2 VLAN 3 VLAN 4 Figure 3 4 One switch connected to four VLANs in a port based VLAN NOTES The same VLAN members must be connected to the same switch VLAN members can t access another VLAN s members The switch manager must a...

Page 23: ...cess VLAN 1 and VLAN 3 members but they can access VLAN 4 members VLAN 3 members can t access VLAN 1 VLAN 2 and VLAN 4 VLAN 4 members can t access VLAN 1 and VLAN 3 members but they can access VLAN 2 members 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports 20 24 Port 10 100BASE TX L2 Managed PoE Switch w...

Page 24: ...witch management function RS 232 console and Ethernet port Use one to monitor and configure the switch Follow the instructions in Sections 3 4 1 and 3 4 2 NOTE Modify the IP address subnet mask default gateway and DNS through the RS 232 console 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports CHAPTER 3 Installation 21 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Du...

Page 25: ...ial RS 232 DB9 connector 2 Attach the other end of the serial RS 232 DB9 cable to the PC s serial port running a terminal emulator supporting a VT100 ANSI terminal with the switch s serial port default settings For example use the Windows 98 2000 XP HyperTerminal utility NOTE The switch s serial port default settings are listed below Baud rate 57600 Stop bits 1 Data bits 8 Parity N Flow control No...

Page 26: ...tch s IP address then change the default gateway s IP address and subnet mask For example suppose your network address is 10 1 1 0 and the subnet mask is 255 255 255 0 You can change the switch s default IP address 192 168 1 1 to 10 1 1 1 and set the subnet mask to 255 255 255 0 Then choose the default gateway s address for example 10 1 1 254 After completing these settings reboot it so the config...

Page 27: ... steps listed below 1 Connect the switch and PC together via UTP CAT5 cable with RJ 45 connectors NOTE If the PC directly connects to the switch set up the same subnet mask between them If the PC connects to the switch through a remote site the remote PC s subnet mask may be different 2 Run CLI or a Web browser and follow the menus For details refer to Chapters 4 and 5 3 A login screen appears Typ...

Page 28: ...s is less than 126 255 255 255 A total of 126 networks can be defined The address 0 0 0 0 is reserved for default route and 127 0 0 0 8 is reserved for loop back function Class B The IP address ranges between 128 0 0 0 and 191 255 255 255 Each class B network has a 16 bit network prefix followed by a 16 bit host address There are 16 384 214 16 networks that can be defined with a maximum of65534 21...

Page 29: ... with all zeros and all ones host number As shown in the table below the subnet mask with a 25 bit long 255 255 255 128 address contains 126 members in the subnetted network The network prefix length equals the bit number with 1s in that subnet mask Use this table to count the number of IP addresses matched Table 3 3 Subnet mask values Prefix Length Number of IPs Matched Number of Addressable IPs ...

Page 30: ...255 255 255 x is allowed 3 5 4 DNS The Domain Name Server translates a human readable machine name to an IP address Every machine on the Internet has a unique IP address A server generally has a static IP address To connect to a server the client needs to know the server s IP However a user generally uses the name to connect to the server Thus the switch DNS client program such as a browser will a...

Page 31: ...FTTB FTTO CONNECTION Figure 3 10 shows a FTTB FTTO application is used in carrier or ISP Figure 3 10 Network Connection of FTTB FTTO 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports 28 ...

Page 32: ...3 6 2 FTTH CONNECTION Figure 3 11 shows a FTTH application is used in carrier or ISP Figure 3 11 Network Connection of FTTH CHAPTER 3 Installation 29 ...

Page 33: ...IN FIBER NETWORK CONNECTION Figure 3 12 shows the Daisy Chain Fiber Network Connection Figure 3 12 Typical office network using three switches 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports 30 ...

Page 34: ...a a network port you must first configure the switch in its command line interface CLI from the connected a sync serial COM RS 232 interface For details see Chapter 5 Once you configure the switch type in the IP address for example http 192 168 1 1 in the address row in a browser The login screen appears Table 4 2 lists the screen options Table 4 2 Login screen parameters Parameter Setting Usernam...

Page 35: ...f the screen the switch s front panel diagram appears The linked ports display green and the unlinked ports appear dark The slot shows only a coverplate if no module exists and it shows a module if a module is present The module image depends on the one that s installed in the switch If disconnected the port will appear dark if linked it will be green Simply click on the ports in the switch diagra...

Page 36: ...ystem time Its format is day of week month day hours minutes seconds year For example Wed Apr 26 12 10 10 2006 BIOS Version The switch s BIOS version Firmware Version The switch s firmware version Hardware Mechanical Version The electrical and mechanical switch version The figure before the hyphen is the electronic hardware version the one after the hyphen is the mechanical hardware version Serial...

Page 37: ...h will issue the request and show the IP address as requesting until the DHCP server is up Before getting an IP address from the DHCP server the device will not continue booting procedures If this field is set to Disable you must type in the IP address manually For more details about IP address and DHCP see Section3 5 The default setting is Disable IP address If DHCP is set to Disable you can type...

Page 38: ...me address into an IP address There are two ways to specify the DNSIP address Fixed mode manually specifies its IP address and dynamic mode is assigned by the DHCP server while DHCP is enabled DNS can help you easily remember the mnemonic address name with meaningful words The default is no DNS address assignment Default 0 0 0 0 Apply button Click on this button to save the changes 4 2 3 TIME CONF...

Page 39: ...user defined NTP server as well as Time Zone the switch will sync the time after you press the Apply button Though it synchronizes the time automatically NTP does not update the time periodically without user processing Time Zone is an offset time of GMT From the drop down menu select the time zone first and then perform time sync via NTP The switch will combine this time zone offset and update NT...

Page 40: ...Click on this button to apply the settings 4 2 4 ACCOUNT CONFIGURATION To get to the Account Configuration screen click on Account in the System menu Only the user logged in as administrator can create modify or delete the username and password The administrator can modify other guest identities passwords without confirming the password but must also modify the administrator equivalent identity A ...

Page 41: ...tions excluding the connection inside the accepting range 5 When both accept and deny lists exist then the switch will deny all connections excluding the connection inside the accepting range and NOT inside of the denying range at the same time Management Security Configuration With the Management Security Configuration function see Table 4 7 the manager can easily control the user s mode when con...

Page 42: ...Custom button you can check the box next to the option you want to use to access and manage the switch The three options include HTTP Telnet and SNMP Action The switch supports two options for managed valid Action Type Deny and Accept The default is the Deny button When you choose Deny you can t manage the switch If you click on the Accept button you can manage the switch Edit Create Click on this...

Page 43: ...r the Master device with the smaller MAC value will be the Master one All 16 devices can become a Master device and back up each other Table 4 8 Virtual Stack screen options Parameter Description State Activates or de activates VSM Select Enable or Disable from the drop down menu The default is Enable Role The role that the switch plays in the virtual stack Select Master or Slave from the drop dow...

Page 44: ...nk Shows if the link on the port is active or not If the link is connected to a device that is working properly the Link will show the link Up otherwise it will show Down Both connected devices determine the link value No default value State Shows that the port s communication function is Enabled or Disabled When it s enabled traffic can be transmitted and received via this port When it s disabled...

Page 45: ...and Full duplex only If the media is 1000Mbps with fiber media it will show only 1000M Full duplex Default None depends on the negotiation result Rx Pause The way that the port adopts to process the PAUSE frame If it shows on the port will care the PAUSE frame otherwise the port will ignore the PAUSE frame Default None Tx Pause It decides that whether the port transmits the PAUSE frame or not If i...

Page 46: ...on3 RX PWR Shows the SFP module s receiver power Close button Click on this button to close the window 4 3 2 CONFIGURATION Use the Configuration menu to change each port s setting To get to this screen click on Config in the Port menu In this menu you can set reset the following functions All are described in detail in Table 4 11 Table 4 11 Configuration screen options Parameter Description State ...

Page 47: ...mmetric both parties can send PAUSE frame to the transmitting device s if the receiving port is too busy to handle When it is set Asymmetric this will let the receiving port care the PAUSE frame from transmitting device s but it doesn t send PAUSE frame This is one way flow control Default Symmetric Apply Click on this button to save the settings 4 3 3 SIMPLE COUNTER Simple Counter collects any in...

Page 48: ...s received 4 3 4 DETAIL COUNTER The Detail Counter collects any information and provides the port traffic counting whether the packet is good or bad To get to this screen click on Detail Counter in the Port Configuration screen The Detail Counter window can show only one port counter information at the same time To get to this screen click on Detail Counter in the Port menu To see another port s c...

Page 49: ...umber of the received broadcast packets Rx Multicast Packets Show the counting number of the received multicast packets Rx Pause Packets Show the counting number of the received pause packets Tx Collisions Number of collisions transmitting frames experienced TX Single Collision Number of frames transmitted that experienced exactly one collision Tx Multiple Collision Number of frames transmitted th...

Page 50: ...otal transmitted bytes Tx Unicast Packets Show the counting number of the transmitted unicast packets Tx Broadcast Packets Show the counting number of the transmitted broadcast packets Tx Multicast Packets Show the counting number of the transmitted multicast packets Tx Pause Packets Show the counting number of the transmitted pause packets Rx FCS Errors Number of bad FSC packets received Rx Align...

Page 51: ...t Port Off Port is turned off due to the DC Disconnect function Overload Port Off The switch will stop supplying the power to the port due to the power required by the PD that is linked to the port on the switch excesses the Class setting of the PD Short Circuit Port Off The switch will stop supplying the power to the port if it detects that the PD linked to the port is short circuit Over Temp Pro...

Page 52: ... the power limit As the ports have the same priority then the switch will cease the power supplement from the port with the highest port id 12Æ1 Power W The power is consumed by the port Current mA The current is supplied to the PD by the port Class The Class of the PD linked to the port of the switch 4 5 SNMP Configuration Any Network Management System NMS running the Simple Network Management Pr...

Page 53: ...e same group Hence the requesting network management unit can not access the device with different community name via SNMP protocol If they both have the same community name they can talk each other Community name is user definable with a maximum length of 15 characters and is case sensitive There is not allowed to put any blank in the community name string Any printable character is allowable The...

Page 54: ...Apply button Click on this button to apply the settings 4 6 DHCP Boot The DHCP Boot function is used to spread the request broadcast packet into a bigger time frame to prevent the traffic congestion due to broadcast packets from many network devices which may seek its NMS boot server DHCP server and many connections predefined when the whole building or block lose the power and then reboot and rec...

Page 55: ...lticast group that had not been built up in advance 4 7 1 STATUS Table 4 18 shows the IGMP Snooping status screen options Table 4 18 Status screen options Parameter Description IGMP Snooping Status IGMP is used to snoop the status of IP multicast groups and display its associated information in both tagged VLAN and non tagged VLAN networks Enabling IGMP with either passive or active mode you can m...

Page 56: ...s Any In case that Custom had been chosen you can assigned effective IP range The valid range is 224 0 0 0 239 255 255 255 VID The switch supports two kinds of options for managed valid VLAN VID including Any and Custom Default is Any When you choose Custom you can fill in VID number The valid VID range is 1 4094 Port The switch supports two kinds of options for managed valid port range including ...

Page 57: ...based from the drop down menu any packet coming in or going out from any one port of a port based VLAN will be accepted No filtering criterion applies in port based VLAN The only criterion is the physical port you connect to For example a port based VLAN namedPVLAN 1 contains port members 1 4 If you are on port 1 you can communicate with ports 2 4 If you are on the port 5 then you can t talk to th...

Page 58: ...ormation of the VLAN to learn or look up the membership information of the VLAN While SVL is disable it means learning mode is IVL In this mode different VLAN uses different filtering database storing the membership information of the VLAN to learn or look up the information of a VLAN member Double Tag Double tag mode belongs to the tag based mode however it would treat all frames as the untagged ...

Page 59: ...member of the VLAN Just tick the check box beside the port x to enable it Add Group To create a new tag based LAN type in the VLAN name and the VID configure the SYM VLAN function and choose the member by checking the box beside the port number 1 8 1 16 or 1 24 Click on the Apply button for the setting to take effect Table 4 22 describes the Tag based VLAN Add Group screen options Table 4 22 Add G...

Page 60: ...ed as the tagged packet with VID y Default Priority It bases on 802 1p QoS and affects untagged packets When the packets enter the switch it would get the priority precedence according to your Default Priority setting and map to 802 1p priority setting in QoS function For example while you set Default Priority of port 2 with 2 and transmit untagged packets to port 2 these packets will own priority...

Page 61: ... group entry and press the Edit button then you can modify a group s description and member set 4 9 MAC Table MAC Table Configuration gathers many functions including MAC Table Information MAC Table Maintenance Static and MAC Alias which cannot be categorized to some function type They are described below 4 9 1 MAC TABLE INFORMATION To get to this screen click on MAC Table Information in the MAC T...

Page 62: ...e An idle MAC address exceeding MAC Address Age out Time will be removed from the MAC Table The range of Age out Time is 10 1000000 seconds and the setup of this time will have no effect on static MAC addresses In addition the learning limit of MAC maintenance is able to limit the amount of MAC that each port can learn Table 4 26 MAC Table Maintenance screen options Parameter Description Aging Tim...

Page 63: ... Valid range is 1 4094 Queue Priority Set up the priority 0 3 for the MAC Forwarding Rule Drop Policy Static A MAC address is assigned to a specific port all of the switch s traffics sent to this MAC address will be forwarded to this port Static with Destination Drop While the DA of the incoming packets meets the value you set up these packets will be dropped Static with Source Drop While the SA o...

Page 64: ...e Delete button in the Tag based Group screen 4 10 GVRP Configuration GVRP is an application based on Generic Attribute Registration Protocol GARP mainly used to automatically and dynamically maintain the group membership information of the VLANs The GVRP offers the function providing the VLAN registration service through a GARP application It makes use of GARP Information Declaration GID to maint...

Page 65: ...ve Time in unit of centisecond Valid time range 60 300 centisecond Default 60 centisecond Leave All Time A time period for announcement that all registered device is going to be de registered If someone still issues a new join then a registration will be kept in the switch Valid range 1000 5000 unit time Default 1000 unit time Default Applicant Mode The mode here means the type of participant Ther...

Page 66: ... messages and all members remain in the unregistered EMPTY state Restricted Mode This function is used to restrict dynamic VLAN be created when this port received GVRP PDU There are two modes disable and enable provided for the user s choice Disabled In this mode the switch dynamic VLAN will be created when this port received GVRP PDU The default setting is Normal Enabled In this mode the switch d...

Page 67: ...ve Empty message is received transmitted by the GARP application Empty Message Packets Number of GARP BPDU with Empty message is received transmitted by the GARP application 4 10 3 GVRP GROUP INFORMATION Table 4 31 GVRP Group Information screen options Parameter Description Current Dynamic Group Number The number of GVRP group that are created currently VID VLAN identifier When GVRP group creates ...

Page 68: ...e Priority Show this switch s current bridge priority setting Default is 32768 Designated Root Show root bridge ID of this network segment If this switch is a root bridge the Designated Root will show this switch s bridge ID Designated Priority Show the current root bridge priority Root Port Show port number connected to root bridge with the lowest path cost Root Path Cost Show the path cost betwe...

Page 69: ...e is the accumulated time in unit of seconds the STP has been since the last STP Topology Change was made When Topology Change is initiated again this counter will be reset to 0 And it will also count again once STP topology Change is completed 4 11 2 STP CONFIGURATION The STP Spanning Tree Protocol actually includes RSTP In the Spanning Tree Configuration there are six parameters open for the use...

Page 70: ... set the root bridge forward delay time This figure is set by root bridge only The forward delay time is defined as the time spent from Listening state moved to Learning state and also from Learning state moved to Forwarding state of a port in bridge The forward delay time contains two states Listening state to Learning state and Learning state to Forwarding state It assumes that forward delay tim...

Page 71: ... to Root Bridge STP algorithm determines a best path to Root Bridge by calculating the sum of path cost contributed by all ports on this path A port with a smaller path cost value would become the Root Port more possibly Configured Path Cost The range is 0 200 000 000 In the switch if path cost is set to be zero the STP will get the recommended value resulted from auto negotiation of the link acco...

Page 72: ...appen on point to point links and on edge ports This can expedite the convergence because this will have the port fast transited to forwarding state There are three parameters Auto True and False used to configure the type of the point to point link If configure this parameter to be Auto it means RSTP will use the duplex mode resulted from the auto negotiation In today s switched networks most lin...

Page 73: ...her LACP groupID to form a logic trunked port The benefit of using Static Trunk method is that a port can immediately become a member of a trunk group without any handshaking with its peer port This is also a disadvantage because the peer ports of your static trunk group may not know that they should be aggregate together to form a logic trunked port Using Static Trunk on both end of a link is str...

Page 74: ...his field is only referenced when a port s trunking method is LACP Active An Active LACP port begins to send LACPDU to its link partner right after the LACP protocol entity started to take control of this port Passive A Passive LACP port will not actively send LACPDU out before it receives an LACPDU from its link partner Aggtr Aggtr is an abbreviation of aggregator Every port is also an aggregator...

Page 75: ...ports within an aggregator port This page shows the detailed information of the LACP trunking group Table 4 37 LACP Detail screen options Parameter Description Actor The switch you are watching on Partner The peer system from this aggregator s view System Priority Show the System Priority part of a system ID MAC Address Show the MAC Address part of a system ID Port Show the port number part of an ...

Page 76: ...on and waits for gaining authorization before sending or receiving any packets from a 802 1x enabled port Before the devices or end stations can access the network resources through the ports under 802 1x control the devices or end stations connected to a controlled port send the authentication request to the authenticator the authenticator pass the request to the authentication server to authenti...

Page 77: ...ing the supplicant can only touch the authenticator to perform authentication message exchange or access the network from the uncontrolled port Figure 4 1 In the Fig 4 2 this is the typical configuration a single supplicant an authenticator and an authentication server B and C is in the internal network D is Authentication server running RADIUS switch at the central location acts Authenticator con...

Page 78: ...n EAP Response Identity to the authenticator The authenticator will embed the user ID into Radius Access Request command and send it to the authentication server for confirming its identity 6 After receiving the Radius Access Request the authentication server sends Radius Access Challenge to the supplicant for asking for inputting user password via the authenticator PAE 7 The supplicant will conve...

Page 79: ... the switch In this mode for the devices connected to this port once a supplicant is authorized the devices connected to this port can access the network resource through this port 802 1x Port based Network Access Control function supported by the switch is little bit complex for it just support basic Multihost mode which can distinguish the device s MAC address and its VID The following table is ...

Page 80: ...o configure the global parameters for RADIUS authentication in 802 1x port security application Radius Server RADIUS server IP address for authentication Default 192 168 1 1 Port Number The port number to communicate with RADIUS server for the authentication service The valid value ranges 1 65535 Default port number is 1812 Secret Key The secret key between authentication server and authenticator ...

Page 81: ...r unauthorized Table 4 42 Port Security Management screen options Parameter Description Disable Mode When selecting Disable mode for a port in the function 802 1X Port Mode Configuration the port is in the uncontrolled port state and does not apply 802 1X authenticator on it Any node attached on this port can access the network without the admittance of 802 1X authenticator The Port Status will sh...

Page 82: ... to hold in the unauthorized state ForceAuthorized The controlled port is forced to hold in the authorized state Auto The controlled port is set to be in authorized state or unauthorized state depends on the result of the authentication exchange between the authentication server and the supplicant Default Auto reAuthMax 1 10 The number of authentication attempt that is permitted before the port be...

Page 83: ...ble the switch to send out the trap information while pre defined trap events occurred The switch offers 22 different trap events to users for switch management The trap information can be sent out in three ways including email mobile phone SMS short message system and trap The message will be sent while users tick the trap event individually on the web page shown as below Table 4 44 Events Config...

Page 84: ...l address that would like to receive the alarm message SMS SMS Server the IP address of the server transferring your SMS Username your username in ISP Password your username in ISP Mobile Phone 1 6 the mobile phone number that would like to receive the alarm message 4 15 Configuration The switch supports three copies of configuration including the default configuration working configuration and us...

Page 85: ...uration function can retrieve the manufacturer s setting to replace the start configuration However the switch s current IP address that the user set up will not be changed and will not be restored to 192 168 1 1 Restore User Configuration The Restore User Configuration function can retrieve the previous confirmed working configuration stored in the Flash memory to update the start configuration W...

Page 86: ...toring Valid port is Port 1 26 and default is Port 1 Monitored Ingress Port Set up the port for being monitored It only monitor the packets received by the port you set up Just tick the check box beside the port x and valid port is Port 1 26 Monitored Egress Port Set up the port for being monitored It only monitor the packets transmitted by the port you set up Just tick the check box beside the po...

Page 87: ... received by the port with the Ingress mode of Restricted Group will be sent to the ports with the Egress mode of Restricted Group Table 4 50 Restricted Group screen options Parameter Description Mode Used for the activation or de activation of Restricted Group function Default is disable Ingress Select the ports that you would like their Restricted Group to set into Ingress mode Just tick the che...

Page 88: ...ss Bandwidth Setting function is used to set up the limit of Egress bandwidth for each port Table 4 52 Egress Bandwidth Setting screen options Parameter Description Port No Choose the port that you would like this function to work on it Valid range of the port is 1 26 Rate Set up the limit of Egress bandwidth for the port you choose Packet transmission will be delayed if the rate exceeds the value...

Page 89: ... supports 5 kinds of QoS are as follows MAC Priority 802 1p Priority IP TOS Priority and DiffServ DSCP Priority Port Based Priority has a special name called VIP Port in the switch Any packets enter VIP Port will have highest transmitting priority MAC Priority act on the destination address of MAC in packets VLAN tagged Priority field is effected by 802 1p Priority setting IP TOS Priority affects ...

Page 90: ...rity in egress queue of the switch The QoS functions as we mentioned above are able to enabled at the same time But the following precedence will decide whether these functions work or not 1 enable both VIP and TOS Choose priorities of VIP and TOS 2 enable both VIP and DSCP Choose priorities of VIP and DSCP 3 enable both TOS and DSCP Choose DSCP 4 enable both VIP and DSCP Choose priorities of VIP ...

Page 91: ...ets enter this port and will have highest transmitting priority For example as you choose port 2 is VIP Port simultaneously transmit packets from port 2 and port 3 to port 1 at speed of 100MB and let congestion happen The packets for port 3 will be dropped because the packets from port 2 owns highest precedence For the sake of this function taking effect you must choose Scheduling Method of Strict...

Page 92: ...bits D Type Delay Priority 1 bit T Type Throughput Priority 1bit R Type Reliability Priority 1bit M Type Monetary Cost Priority 1bit and UNUSED PRECEDENCE 3 bits can arrange 8 kinds of priorities corresponding to the 0 7 priority in the following priority diagram TOS Delay Priority Mapping works while D TYPE in TOS field of IP header of the packets received by the switch is configured Figure 4 5 T...

Page 93: ...n Default Priority 0 is mapping to Queue 0 Priority 1 is mapping to Queue 0 Priority 2 is mapping to Queue 1 Priority 3 is mapping to Queue 1 Priority 4 is mapping to Queue 2 Priority 5 is mapping to Queue 2 Priority 6 is mapping to Queue 3 and Priority 0 is mapping to Queue 3 4 18 6 R TYPE TOS IP TOS Priority affect TOS fields of IP header you can find it has 8 bit SERVICE TYPE field that specifi...

Page 94: ...TOS Priority affect TOS fields of IP header you can find it has 8 bit SERVICE TYPE field that specifies how the datagram should be handled The field could be divided into six subfields as follows PRECEDENCE 3 bits D Type Delay Priority 1 bit T Type Throughput Priority 1bit R Type Reliability Priority 1bit M Type Monetary Cost Priority 1bit and UNUSED PRECEDENCE 3 bits can arrange 8 kinds of priori...

Page 95: ...re mapping to Queue 1 Priority 32 47 are mapping to Queue 0 Priority 48 63 are mapping to Queue 0 4 19 Diagnostics Three functions including Diagnostics Loopback Test and Ping Test are contained in this function folder for device self diagnostics Each of them will be described in detail orderly in the following sections 4 19 1 DIAGNOSTICS Diagnostics function provides a set of basic system diagnos...

Page 96: ...ocates Fill in the IP address of your TFTP server then press Apply button to have the setting taken effect 4 21 Log This function shows the log data The switch provides system log data for users There are 17 private trap logs 5 public trap logs The switch supports total 120 log entries For more details on log items please refer to the section of Trap Alarm Configuration and SNMP Configuration Tabl...

Page 97: ...tware worked NOTE Software upgrade is hazardous if power is off You must do it carefully Table 4 65 Firmware Upgrade screen options Parameter Description TFTP Server A TFTP server stored the image file you want to upgrade Path and Filename File path and filename stored the image file you want to upgrade 4 23 Reboot We offer you many ways to reboot the switch including power up hardware reset and s...

Page 98: ...out and exit the browser the switch will automatically have you logout Besides this manually logout and implicit logout you can pull down the Auto Logout list at the left top corner to explicitly ON OFF this logout function Table 4 67 Logout screen options Parameter Description Auto Logout Default is ON If it is ON and no action and no key is stroke as well in any function screen more than 3 minut...

Page 99: ...ise it appears as The former means you act as an administrator and have all system access rights The latter means you act as a guest and are only allowed to view the system without permission to apply configuration settings to the switch 5 2 Commands To see the CLI mode commands type in a after the prompt then all commands will be listed All command scan be divided into two categories global and l...

Page 100: ... PSES 2126C 802 1x Enter into 802 1x mode account Enter into account mode alarm Enter into alarm mode autologout Change autologout time bandwidth Enter into bandwidth mode config file Enter into config file moded dhcp boot Enter into dhcp boot mode diag Enter into diag mode firmware Enter into firmware mode gvrp Enter into gvrp mode hostname Change hostname Igmp snooping Enter into igmp mode ip En...

Page 101: ...more than two words When you enter this command the CLI shows the complete commands This command also helps you classify the commands as either local or global commands Argument None Possible value None Example Giga Switch ip Giga Switch ip help Commands available Local commands set ip Set ip subnet mask and gateway set dns Set dns enable dhcp Enable DHCP and set dns auto or manual disable dhcp Di...

Page 102: ...re run When you enter this command the CLI shows a list of commands that you typed previously The CLI supports up to 256 records If you don t type in anything the CLI lists up to 256 total records If you do type in a number the CLI only shows the records last numbers Argument show last number of history records optional Possible value 1 2 3 256 Example Giga Switch ip history Command history 0 trun...

Page 103: ... restore the default IP address y n If you choose Y or y the IP address will restore to the default 192 168 1 1 If you choose N or n the IP address will keep the same one that you saved before If restoring the default is successful the CLI asks if it will reboot immediately or not Pressing Y or y reboots the system immediately otherwise it goes back to the CLI system After restoring the default co...

Page 104: ...Restoring Restore User Configuration Successfully Press any key to reboot system save start Syntax save start Description Saves the current configuration as the startup one When you enter this command the CLI saves your current configuration to the nonvolatile Flash If you want the configuration to work after rebooting save the configuration using the command save start Argument None Possible valu...

Page 105: ...achine will retransmit an EAP Request packet to the Supplicant before it times out the authentication session Argument port range syntax 1 5 7 available from 1 to 8 times max times range 1 10 Possible value port range 1 to 8 times 1 10 default is 2 Example Giga Switch 802 1X set max request 2 2 set mode Syntax set mode port range mode Description Sets up each port s 802 1x authentication mode Argu...

Page 106: ... 1 to 8 authorized 0 1 or 2 Example Giga Switch 802 1X set port control 2 2 set quiet period Syntax set quiet period port range sec Description A timer that the Authenticator state machine uses to define time periods when it won t attempt to acquire a Supplicant A state machine is a service within the switch that monitors connections and times them out when the time reaches a set maximum time Argu...

Page 107: ... Possible value port range 1 to 8 ebl 0 or 1 default is 1 Example Giga Switch 802 1X set reAuthEnabled 2 1 set reAuthMax Syntax set reAuthMax port range max Description The number of reauthentication attempts that are permitted before the port becomes unauthorized Argument port range syntax 1 5 7 available from 1 to 8 max max value range 1 10 Possible value port range 1 to 8 max 1 10 default is 2 ...

Page 108: ... the backend authentication state machine determines timeout conditions in the exchanges between the Authenticator and the Supplicant or Authentication Server A state machine is a service within the switch that monitors connections and times them out when the time reaches a set maximum time The initial value of this timer is either suppTimeout or serverTimeout as determined by the backend Authenti...

Page 109: ... timer used by the Backend Authentication state machine that determines timeout conditions in the exchanges between the Authenticator and the Supplicant or Authentication Server A state machine is a service within the switch that monitors connections and times them out when the time reaches a set maximum time The timer s initial value is either suppTimeout or serverTimeout as determined by the Bac...

Page 110: ... available from 1 to 8 sec timer range 1 65535 Possible value port range 1 to 8 sec 1 65535 default is 30 Example Giga Switch 802 1X set txPeriod 2 30 show mode Syntax show mode Description Displays each port s mode Argument None Possible value None Example Giga Switch 802 1X show mode Port Mode 1 Disable 2 Multi host 3 Disable 4 Disable 5 Disable 6 Disable CHAPTER 5 CLI Management 108 ...

Page 111: ...60 reAuthEnabled ON reAuthPeriod 3600 max Request 2 suppTimeout 30 serverTimeout 30 port 2 port control Auto reAuthMax 2 txPeriod 30 Quiet Period 60 reAuthEnabled ON reAuthPeriod 3600 max Request 2 suppTimeout 30 serverTimeout 30 show security Syntax show security Description Displays each port s authentication status Argument None Possible value None 24 Port 10 100BASE TX L2 Managed PoE Switch wi...

Page 112: ...us server s configuration Argument None Possible value None Example Giga Switch 802 1X show state Radius Server 192 168 1 115 Port Number 1812 Secret Key WinRadius account add Syntax add name Description Creates a new guest user Type in a password and confirm it when prompted Argument name new account name Possible value A string must be at least 5 characters CHAPTER 5 CLI Management 110 ...

Page 113: ...aaaa Account aaaaa deleted Modify Syntax modify name Description Changes an existing account s username and password Argument name existing user account Possible value None Example Giga Switch account modify aaaaa username password the length is from 5 to 15 Current username aaaaa bbbbb New password Confirm password Username changed successfully Password changed successfully 24 Port 10 100BASE TX ...

Page 114: ...mail address Syntax del mail address Description Removes the email address configuration Argument email address number range of 1 to 6 Possible value 1 to 6 Example Giga Switch alarm email del mail address 2 del server user yntax del server user Description Removes the server user account and password configuration Argument None Possible value None Example Giga Switch alarm email del server user C...

Page 115: ...t server ip Description Sets up the email server s IP address Argument ip email server ip address or domain name Possible value None Example Giga Switch alarm email set server 192 168 1 6 set user Syntax set user username Description Sets up the email server s account and password Argument username email server account and password Possible value None Example Giga Switch alarm email set user admin...

Page 116: ...me admin Password Email Address 1 abc mail abc com Email Address 2 Email Address 3 Email Address 4 Email Address 5 Email Address 6 events del all Syntax del all range Description Disables email sms and events trap Argument range del the range of events syntax 1 5 7 Possible value range 1 24 Example Giga Switch alarm events del all 1 3 CHAPTER 5 CLI Management 114 ...

Page 117: ...e Description Disables the events sms Argument range del the range of sms syntax 1 5 7 Possible value range 1 26 Example Giga Switch alarm events del sms 1 3 del trap Syntax del trap range Description Disables the events trap Argument range del the range of trap syntax 1 5 7 Possible value range 1 26 Example Giga Switch alarm events del trap 1 3 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 S...

Page 118: ...s email Argument range set the range of email syntax 1 5 7 Possible value range 1 26 Example Giga Switch alarm events set email 1 3 set sms Syntax set sms range Description Enables the events sms Argument range set the range of sms syntax 1 5 7 Possible value range 1 26 Example Giga Switch alarm events set sms 1 3 set trap Syntax set trap range Description Enables the events trap Argument range se...

Page 119: ...Link Up v 5 Authentication Failure v 6 User Login 7 User Logout 8 STP Topology Changed 9 STP Disabled 10 STP Enabled 11 LACP Disabled 12 LACP Enabled 13 LACP Member Added 14 LACP Port Failure 15 GVRP Disabled 16 GVRP Enabled 17 VLAN Disabled 18 Port based Vlan Enabled 19 Tag based Vlan Enabled 20 Metro mode Vlan Enabled 21 Double tag Vlan Enabled 22 Module Inserte 23 Module Removed 24 Module Media...

Page 120: ...s sms del phone number Syntax del phone number Description Deletes the sms phone number Argument mobile phone number range of 1 to 6 Possible value 1 to 6 Example Giga Switch alarm sms del phone number 3 del server user Syntax del server user Description Deletes sms server user account and password Argument None Possible value None Example Giga Switch alarm sms del server user CHAPTER 5 CLI Manage...

Page 121: ...x set server ip Description Sets up the sms server s IP address Argument ip SMS server ip address or domain name Possible value None Example Giga Switch alarm sms set server 192 168 1 7 set user Syntax set user username Description Sets up the sms server s user account and password Argument username SMS server account Possible value None Example Giga Switch alarm sms set user ABC 24 Port 10 100BAS...

Page 122: ...one 1 0968777777 Mobile Phone 2 Mobile Phone 3 Mobile Phone 4 Mobile Phone 5 Mobile Phone 6 autologout autologout Syntax autologout time Description Sets up the autologout timer Argument time range 1 to 3600 seconds 0 for autologout off current setting is 180 seconds Possible value time 0 1 3600 Example Giga Switch autologout 3600 Set autologout time to 3600 seconds CHAPTER 5 CLI Management 120 ...

Page 123: ...te range Description Cancels the port s Ingress rate Argument range syntax 1 5 7 available from 1 to 8 Possible value range 1 to 8 Example Giga Switch bandwidth disable ingress rate 1 8 disable storm rate Syntax disable storm rate range Description Cancels the port s storm rate Argument range syntax 1 5 7 available from 1 to 8 Possible value range 1 to 8 Example Giga Switch bandwidth disable storm...

Page 124: ...dwidth enable egress rate 1 8 200 enable ingress rate Syntax enable ingress rate range data_rate Description Sets up the port s Ingress rate Argument range syntax 1 5 7 available from 1 to 8 data_rate 0 1000 Possible value range 1 to 8 data_rate 0 1000 Example Giga Switch bandwidth enable ingress rate 1 8 100 enable storm rate Syntax enable storm rate range data_rate Description Sets up the port s...

Page 125: ... Example Giga Switch bandwidth show Ingress Egress Port All State All Rate Storm State Storm Rate All state All Rate 1 Disabled 0 Disabled 0 Disabled 0 2 Disabled 0 Disabled 0 Disabled 0 3 Disabled 0 Disabled 0 Disabled 0 4 Disabled 0 Disabled 0 Disabled 0 5 Disabled 0 Disabled 0 Disabled 0 6 Disabled 0 Disabled 0 Disabled 0 7 Disabled 0 Disabled 0 Disabled 0 8 Disabled 0 Disabled 0 Disabled 0 24 ...

Page 126: ...port user conf Syntax export user conf Description Runs the export user conf function Argument None Possible value None Example Giga Switch config file export user conf Export successful import start Syntax import start Description Runs the import start function Argument None Possible value None Example Giga Switch config file import start Import successful CHAPTER 5 CLI Management 124 ...

Page 127: ... exported Argument filepath filepath and filename Possible value filepath filepath and filename Example Giga Switch config file set export path log 21511 txt set import path Syntax set import path filepath Description Sets up the filepath and filename that will be imported Argument filepath filepath and filename Possible value filepath filepath and filename Example Giga Switch config file set impo...

Page 128: ...ilename user123 txt dhcp boot set dhcp boot Syntax set dhcp boot sec Description Sets up the DHCPBoot delay time Argument sec range syntax 0 1 30 0 disables dhcp boot delay Possible value sec 0 30 Example Giga Switch dhcp boot set dhcp boot 30 show Syntax show Description Displays the DHCP Boot s status Argument None Possible value None Example Giga Switch dhcp boot show dhcp boot Enable Second 10...

Page 129: ...rnal External Loopback Test Argument None Possible value None Example Giga Switch diag loopback Internal Loopback Test OK External Loopback Test Port 1 2 3 4 5 6 7 8 Fail ping Syntax ping ip Description Confirms whether the remote end station or not the switch itself is available Argument ip ip address or domain name Possible value IP address for example 192 168 2 65 or tw yahoo com 24 Port 10 100...

Page 130: ...lepath upgrade file path Example Giga Switch firmware set upgrade path gs2108c_Giga Switch_v2 03 img show Syntax show Description Displays the tftp server and upgrade path information Argument None Possible value None Example Giga Switch firmware show TFTP Server IP Address 192 168 3 111 Path and Filename gs2108c_Giga Switch_v2 03 img upgrade Syntax upgrade Description Runs the upgrade function Ar...

Page 131: ...sible value None Example Giga Switch gvrp enable group Syntax group group number Description Enter any gvrp group for which you want to change the gvrp group setting You can change the applicant or registrar mode of an existing gvrp group per port Argument group number enter which gvrp group you had created using value is vid available range is 1 to 4094 Possible value group number 1 4094 24 Port ...

Page 132: ...Normal Normal 8 Normal Normal Giga Switch gvrp group 2 set registrar 1 8 fixed Giga Switch gvrp group 2 show GVRP group VID 2 Port Applicant Registrar 1 Non Participant Fixed 2 Non Participant Fixed 3 Non Participant Fixed 4 Non Participant Fixed 5 Non Participant Fixed 6 Non Participant Fixed 7 Normal Fixed 8 Normal Fixed set applicant Syntax set applicant range normal non participant Description...

Page 133: ...et registrar as fixed mode forbidden set registrar as forbidden mode Possible value range 1 to 8 normal fixed forbidden normal fixed or forbidden Example Giga Switch gvrp set registrar 1 5 fixed set restricted Syntax set restricted range enable disable Description Sets each port s restricted mode Argument range port range syntax 1 5 7 available from 1 to 8 enable set restricted enabled disable set...

Page 134: ...mal Enable set timer Syntax set timer range join leave leaveall Description Sets each port s gvrp join time leave time and leave all time Argument range port range syntax 1 5 7 available from 1 to 8 join join timer available from 20 to 100 leave leave timer available from 60 to 300 leaveall leaveall timer available from 1000 to 5000 Leave Time must equal double Join Time at least Possible value ra...

Page 135: ...able 8 25 80 2000 Normal Normal Disable show counter Syntax show counter port Description Displays the port s counter number Argument port port number Possible value port available from 1 to 8 Example Giga Switch gvrp show counter 2 GVRP Counter port 2 Counter Name Received Transmitted Total GVRP Packets 0 0 Invalid GVRP Packets 0 LeaveAll message 0 0 JoinEmpty message 0 0 JoinIn message 0 0 Leave...

Page 136: ... hostname maximum of 40 characters Possible value name hostname maximum of 40 characters Example Giga Switch hostname Company Company Igmp snooping set igmp_snooping Syntax set igmp_snooping status Description Sets up the IGMP Snooping mode Argument status 0 disable 1 active 2 passive Possible value status 0 1 or 2 Example Giga Switch igmp set igmp snooping 2 CHAPTER 5 CLI Management 134 ...

Page 137: ...ription Disables the system s DHCP function Argument None Possible value None Example Giga Switch ip disable dhcp enable dhcp Syntax enable dhcp manual auto Description Enables the system DHCP function and sets the DNS server via manual or auto mode Argument manual auto set dhcp by using manual or auto mode Possible value manual auto manual or auto Example Giga Switch ip enable dhcp manual 24 Port...

Page 138: ...ay Argument ip ip address mask subnet mask gateway default gateway Possible value ip 192 168 1 2 or others mask 255 255 255 0 or others gateway 192 168 1 253 or others Example Giga Switch ip set ip 192 168 1 2 255 255 255 0 192 168 1 253 show Syntax show Description Displays the system s DHCP function state IP address subnet mask default gateway DNS mode DNS server IP address and current IP addres...

Page 139: ... 168 95 1 1 log clear Syntax clear Description Clears the log data Argument None Possible value None Example Giga Switch log clear disable auto upload Syntax disable auto upload Description Disables the auto upload function Argument None Possible value None Example Giga Switch log disable auto upload 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports 137 ...

Page 140: ...function to query Up to 120 log records are supported Argument None Possible value None Example Giga Switch log show Tftp Server 0 0 0 0 Auto Upload Disable 1 Wed Apr 13 12 13 27 2005 Link Up Port 1 2 Wed Apr 13 12 13 26 2005 Link Down Port 1 3 Wed Apr 13 11 58 31 2005 Login admin 4 Wed Apr 13 11 19 45 2005 Login admin 5 Wed Apr 13 11 19 37 2005 Logout admin upload Syntax upload Description Upload...

Page 141: ...44 set Syntax set mac alias Description Sets up the MAC alias entry Argument mac MAC address format 00 02 03 04 05 06 alias MAC alias name maximum of 15 characters Possible value None Example Giga Switch mac table alias set 00 44 33 44 55 44 www show Syntax show Description Displays the MAC alias entry Argument None Possible value None 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Me...

Page 142: ...he range of the ports to search for syntax 1 5 7 available from 1 to 8 mac mac address format 01 02 03 04 05 06 can be used vid vlan id from 1 to 4094 represents don t care 0 as untagged Possible value port 1 to 8 vid 0 1 4094 Example Giga Switch mac table information search 1 8 MAC Table List Alias MAC Address Port VID State 00 40 c7 88 00 06 10 Dynamic show Syntax show Description Displays all M...

Page 143: ...c learning MAC s age out time Argument age timer in seconds 0 10 to 65535 0 disables aging Possible value 0 10 to 65535 Example Giga Switch mac table maintain set aging 300 set flush Syntax set flush Description Deletes all dynamically learned MACs Argument None Possible value None Example Giga Switch mac table maintain set flush show Syntax show Description Displays the age timer settings Argumen...

Page 144: ...n id 0 1 4094 VID must be zero if vlan mode is not tag based alias MAC alias name maximum of 15 characters Possible value mac mac address port 0 8 vid 0 1 4094 alias MAC alias name Example Giga Switch mac table static mac add 00 02 03 04 05 06 3 0 aaa del Syntax del mac vid Description Removes the static MAC entry Argument mac MAC address format 00 02 03 04 05 06 vid vlan id 0 1 4094 VID must be z...

Page 145: ...c show filter Static Filtering Entry Total 1 item s 1 mac 00 33 03 04 05 06 vid alias ccc show forward Syntax show forward Description Displays the static forward table Argument None Possible value None Example Giga Switch mac table static mac show forward Static Forwarding Entry Total 1 item s 1 mac 00 02 03 04 05 06 port 3 vid alias aaa 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual...

Page 146: ...ating explanation for setting the management policy records Argument name value ACL entry name vid value VLAN ID ip value IP range port value Incoming port type value Access type action value a ccept or d eny Possible value name value No default and it must be set vid value The range is 1 4095 and can be set to any ip value For example 192 168 1 90 192 168 1 90 or any port value For example 1 or 1...

Page 147: ...68 1 80 Type SNMP Action Deny Port 1 2 Giga Switch management delete 1 Giga Switch management show Security rule list is empty now edit the specific management policy entry Available range of 1 to 65536 Syntax Usage set name value vid value ip value port value type value action value Synopsis set name Mary vid 20 ip 192 168 1 1 192 168 1 90 port 2 5 8 type h s action a Synopsis set name Mary vid 2...

Page 148: ...mple h ttp s nmp t elnet or any action value No default and it must be set Example Giga Switch management edit 1 Giga Switch management edit 1 set name Tom vid 2 ip 192 168 1 30 192 168 1 80 port 1 2 type s action d Giga Switch management edit 1 show 1 Name TomVlanID 2IP 192 168 1 30 192 168 1 80 Type SNMPAction DenyPort 1 2 show Syntax show Description Shows the specific management policy record ...

Page 149: ... poe set priority 1 12 2 set state Syntax set state port range state Description To set the PoE state on ports Argument port range which port s you want to set syntax 1 5 7 available from 1 to 24 state enable or disable PoE function 0 Disable 1 Enable Possible value port range 1 to 24 state 0 or 1 Example PSES 2126C poe set state 11 0 show Syntax show Description To display the PoE status Argument...

Page 150: ...Circuit Port Off X X X X X X X X X X X X Over Temp Protection X X X X X X X X X X X X Power Management Port Off X X X X X X X X X X X X Port No 13 14 15 16 17 18 19 20 21 22 23 24 Port On X X X X X X X X X X X X AC Disconnect Port Off X X X X X X X X X X X X DC Disconnect Port Off X X X X X X X X X X X X Overload Port Off X X X X X X X X X X X X Short Circuit Port Off X X X X X X X X X X X X Over ...

Page 151: ... Normal 0 0 0 0 14 Normal Enable Normal 0 0 0 0 15 Normal Enable Normal 0 0 0 0 16 Normal Enable Normal 0 0 0 0 17 Normal Enable Normal 0 0 0 0 18 Normal Enable Normal 0 0 0 0 19 Normal Enable Normal 0 0 0 0 20 Normal Enable Normal 0 0 0 0 21 Normal Enable Normal 0 0 0 0 22 Normal Enable Normal 0 0 0 0 23 Normal Enable Normal 0 0 0 0 24 Normal Enable Normal 0 0 0 0 port clear counter Syntax clear ...

Page 152: ...on capability Argument range syntax 1 5 7 available from 1 to 8 Possible value range 1 8 Example Giga Switch port disable state 1 2 enable flow control Syntax enable flow control range Description Enables the port s flow control function Argument range syntax 1 5 7 available from 1 to 8 Possible value range 1 8 Example Giga Switch port enable flow control 3 8 enable state Syntax enable state range...

Page 153: ...lex 10M Full 100half set speed duplex 100M Half 100full set speed duplex 100M Full 1Gfull set speed duplex 1G Full Possible value range 1 to 8 port speed auto 10half 10full 100half 100full 1Gfull Example Giga Switch port set speed duplex 5 auto show conf Syntax show conf Description Display each port s state speed duplex and flow control configuration Argument None Possible value None Example Giga...

Page 154: ...FP module information Argument port The switch s SFP port available from 7 8 Possible value port 7 8 Example Giga Switch port show sfp 7 Port 7 SFP information Connector Type SFP LC Fiber Type Multi mode MM Tx Central Wavelength 850 Baud Rate 1G Vendor OUI 00 40 c7 Vendor Name APAC Opto Vendor PN KM28 C3S TC N Vendor Rev 0000 Vendor SN 5425010708 Date Code 050530 Temperature none Vcc none Mon1 Bia...

Page 155: ...dvance layer4 Syntax set advance layer4 port range tcp udp port default match Description Sets the ports class in Layer 4 qos advanced mode Argument port range port range syntax 1 5 7 available from 1 to 8 special UDP TCP port selection range 1 10 tcp udp port range 0 65535 default default class all other TCP UDP ports 1 high 0 low match special TCP UDP class 1 high 0 low Possible value port range...

Page 156: ...ange class Description Sets ports class on IP DiffServe qos Argument ds range dscp field syntax 1 5 7 available from 0 to 63 class class of service setting 1 high 0 low Possible value ds range 0 to 63 class 1 or 0 Example Giga Switch qos set diffserv 0 20 1 set mode Syntax set mode port pri_tag tos layer4 diffserv Description Sets the switch s qos priority mode Argument port per port priority pri_...

Page 157: ...nge 1 to 8 class 1 or 0 Example Giga Switch qos set port 1 8 1 set pri tag Syntax set pri_tag port range tag range class Description Sets ports class on vlan tag based qos Argument port range port range syntax 1 5 7 available from 1 to 8 tag range tag priority level syntax 1 5 7 available from 0 to 7 class class of service setting 1 high 0 low Possible value port range 1 to 8 tag range 0 to 7 clas...

Page 158: ...news 5 prioritize streaming Audio Video 6 prioritize databases Oracle IBM DB2 SQL Microsoft Possible value 0 6 Example Giga Switch qos set simple layer4 2 set tos Syntax set tos port range tos range class Description Sets ports class on IP TOS qos Argument port range port range syntax 1 5 7 available from 1 to 8 tos range tos precedence field syntax 1 5 7 available from 0 to 7 class class of servi...

Page 159: ...high 18 high 19 high 20 high 21 high 22 high 23 high 24 high 25 high 26 high 27 high 28 high 29 high 30 high 31 high 32 high 33 high 34 high 35 high 36 high 37 high 38 high 39 high 40 high 41 high 42 high 43 high 44 high 45 high 46 high 47 high 48 high 49 high 50 high 51 high 2 high 53 high 54 high 55 high 56 high 57 high 58 high 59 high 60 high 61 high 62 high 63 high reboot reboot Syntax reboot ...

Page 160: ...able snmp Giga Switch snmp disable set ability enable Syntax enable set ability enable snmp Description Enable activates snmp or set community Argument None Possible value None Example Giga Switch snmp enable snmp Giga Switch snmp enable set ability set Syntax set get community community set set community community set trap ip port community CHAPTER 5 CLI Management 158 ...

Page 161: ...ription Displays the SNMP configuration Argument None Possible value None Example Giga Switch snmp show SNMP Enable Get Community public Set Community private Enable Trap Host 1 IP Address 192 168 1 1 Port 162 Community public Trap Host 2 IP Address 0 0 0 0 Port 162 Community public Trap Host 3 IP Address 0 0 0 0 Port 162 Community public Trap Host 4 IP Address 0 0 0 0 Port 162 Community public Tr...

Page 162: ...Giga Switch stp enable MCheck Syntax MCheck range Description Forces the port to transmit RST BPDUs RST is the Rapid Spanning Tree IEEE802 1d standard BPDU is an abbreviation for Bridge Protocol Data Unit This is a message type used by bridges to exchange management and control information Argument range syntax 1 5 7 available from 1 to 8 Possible value range 1 to 8 Example Giga Switch stp Mcheck ...

Page 163: ...o 40 Forward Delay 4 to 30 Example Giga Switch stp set config 61440 2 20 15 set port Syntax set port range path cost priority edge_port admin p2p Description Sets up the STP port information Argument range syntax 1 5 7 available from 1 to 8 path cost 0 1 200000000 the value zero means auto status priority priority must be a multiple of 16 available from 0 to 240 edge_port Admin Edge Port yes no ad...

Page 164: ...g Syntax show config Description Displays the STP configuration Argument None Possible value None Example Giga Switch stp show config STP State Configuration Spanning Tree Protocol Enabled Bridge Priority 0 61440 61440 Hello Time 1 10 sec 2 Max Age 6 40 sec 20 Forward Delay 4 30 sec 15 Force Version RSTP show port Syntax show port Description Displays the STP port information Argument None Possibl...

Page 165: ...to 8 DISCARDING 2000000 128 No Auto show status Syntax show status Description Displays the STP status Argument None Possible value None Example Giga Switch stp show status STP Status STP State Enabled Bridge ID 00 40 C7 D8 09 1D Bridge Priority 61440 Designated Root 00 40 C7 D8 09 1D Designated Priority 61440 Root Port 0 Root Path Cost 0 Current Max Age sec 20 Current Forward Delay sec 15 Hello T...

Page 166: ...me string Description Sets the switch s device name description Argument device name string length up to 40 characters Possible value device name A b c d z and 1 2 3 etc Example Giga Switch system set device name CR 2600 set location Syntax set location location string Description Sets the switch s location description Argument location string length up to 40 characters Possible value location A b...

Page 167: ...rsion v1 01 Firmware Version v2 14 Hardware Mechanical Version v1 01 v1 01 Serial Number 030F03000003 Host IP Address 192 168 1 1 Host MAC Address 00 40 c7 de 00 e7 Device Port UART 1 TP 6 Dual Media Port RJ45 SFP 2 RAM Size 16 M Flash Size 2 M tftp set server Syntax set server ip Description Sets the tftp server s IP address Argument ip the IP address of tftp server Possible value ip tftp server ...

Page 168: ...light saving Argument hr daylight saving hour range 5 to 5 MM daylight saving start Month 01 12 DD daylight saving start Day 01 31 HH daylight saving start Hour 00 23 mm daylight saving end Month 01 12 dd daylight saving end Day 01 31 hh daylight saving end Hour 00 23 Possible value Hr 5 to 5 MM 01 12 DD 01 31 HH 00 23 Mm 01 12 dd 01 31 hh 00 23 Example Giga Switch time set daylightsaving 3 10 12 ...

Page 169: ...the current time via Network Time Protocol NTP server This is used to synchronize a computer client or server s time to another server Argument ip ntp server ip address or domain name timezone time zone GMT range 12 to 13 Possible value timezone 12 11 0 1 13 Example Giga Switch time set ntp clock via net 8 Synchronizing 1 Synchronization success show Syntax show Description Shows the time configur...

Page 170: ...del trunk Syntax del trunk port range Description Deletes the trunking port Argument port range port range syntax 1 5 7 available from 1 to 8 Possible value port range 1 to 8 Example Giga Switch trunk del trunk 1 set priority Syntax set priority range Description Sets up the LACP system priority Argument range available from 1 to 65535 Possible value range 1 to 65535 default 32768 Example Giga Swi...

Page 171: ...ctive set the LACP to active mode passive set the LACP to passive mode active LACP Possible value port range 1 to 8 method static lacp group 1 8 active LACP active passive Example Giga Switch trunk set trunk 1 4 lacp 1 active show aggtr view Syntax show aggtr view Description Displays the aggregator list Argument None Possible value None Example Giga Switch trunk show aggtr view Aggregator 1 Metho...

Page 172: ...ty MAC Address System Priority MAC Address 32768 00 40 c7 e8 00 02 32768 00 00 00 00 00 00 Port Key Trunk Status Port Key 2 257 2 0 show lacp priority Syntax show lacp priority Description Displays the LACP Priority s value Argument None Possible value None Example Giga Switch trunk show lacp priority LACP System Priority 32768 show status Syntax show status Description Displays each port s aggreg...

Page 173: ... port group name Description Deletes the port based vlan group Argument name which vlan group you want to delete Possible value name port vlan name Example Giga Switch vlan del port group VLAN 2 del tag group Syntax del tag group vid Description Deletes the tag based vlan group Argument vid which vlan group you want to delete available from 1 to 4094 Possible value vid 1 to 4094 Example Giga Switc...

Page 174: ...rt s you want to set syntax 1 5 7 available from 1 to 8 Possible value range 1 to 8 Example Giga Switch vlan disable sym vlan 5 8 enable drop untag Syntax enable drop untag range Description Drops the untagged frames Argument range which port s you want to set syntax 1 5 7 available from 1 to 8 Possible value range 1 to 8 Example Giga Switch vlan enable drop untag 5 8 enable sym vlan Syntax enable...

Page 175: ... Q in Q function up link syntax 1 5 7 available from 7 to 8 only for metro mode vlan Possible value disable port tag metro double tag disable port tag metro double tag up link 25 or 26 or 25 26 Example Giga Switch vlan set mode port set port group Syntax set port group name range Description Adds or edits a port based VLAN group Argument name port vlan name range syntax 1 5 7 available from 1 to 8...

Page 176: ...xcept a specific VID vid untag vid for hybrid port Possible value range 1 to 8 vid 1 to 4094 Example Giga Switch vlan set port role 5 hybrid 6 set pvid Syntax set pvid range pvid Description Sets the vlan pvid Argument range which port s you want to set PVID s syntax 1 5 7 available from 1 to 8 pvid which PVID s you want to set available from 1 to 4094 Possible value range 1 to 8 pvid 1 to 4094 Ex...

Page 177: ...ible value vid 1 to 4094 range 1 to 8 0 or 1 Example Giga Switch vlan set tag group 2 VLAN 2 2 5 6 8 0 show group Syntax show group Description Displays the vlan mode and vlan group Argument None Possible value None Example Giga Switch vlan show group Vlan mode is double tag 1 Vlan Name default Vlan ID 1 Sym vlan Disable Member 1 2 3 4 5 6 7 8 2 Vlan Name VLAN 2 Vlan ID 2 Sym vlan Disable Member 2...

Page 178: ...isable Access 3 5 Disable Disable Access 4 1 Disable Disable Access 5 5 Enable Disable Hybrid 6 6 5 Enable Disable Access 7 5 Enable Disable Access 8 5 Enable Disable Access vs disable Syntax disable Description Disables the virtual stack Argument None Possible value None Example Giga Switch vs disable enable Syntax enable Description Enables the virtual stack Argument None Possible value None CHA...

Page 179: ...ole Syntax set role master slave Description Sets the role Argument master slave master act as master slave act as slave Possible value master slave master or slave Example Giga Switch vs set role master show Syntax show Description Displays the virtual stack s configuration Argument None Possible value None 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports 177 ...

Page 180: ...Example Giga Switch vs show Virtual Stack Config State Enable Role Master Group ID group1 CHAPTER 5 CLI Management 178 ...

Page 181: ...s are used on that switch Solution 2 Verify that the uplink function is enabled Problem The console interface doesn t appear on the console port connection Solution 1 The COM port default parameters are baud rate 57600 Data bits 8 Parity bits None Stop bit 1 Flow control None Check the COM port values in the terminal program If the parameters are changed set the COM configuration to the default se...

Page 182: ...curs the components involved in the problem any particular application that when used appears to create the problem or make it worse 6 4 Shipping and Packaging If you need to transport or ship your 24 Port 10 100BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports Package it carefully We recommend that you use the original container If you are shipping the 24 Port 10 100BASE TX L2 Managed PoE...

Reviews: