background image

 

 

 

 

 

 

 

 

 

Thank you for purchasing our product. 

 

This manual provides you with important information about safe and 

proper operations of this Switching Hub. 

 

Please read the "Important Safety Instruction" on pages 3 to 5. 

 

Any problems or damage resulting from disassembly of this Switching 

Hub by customers are not covered by the warranty.

 

 

 

Switch-M24eGi 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model Number: PN28240i 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for Menu Interface

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PN28240i-ID

Page 1: ...afe and proper operations of this Switching Hub Please read the Important Safety Instruction on pages 3 to 5 Any problems or damage resulting from disassembly of this Switching Hub by customers are no...

Page 2: ...2 This operation manual is applicable to the following Switching Hubs Product name Model No Firmware version Switch M24eGi PN28240i ID PN28240i TH PN28240i MY PN28240i SG 3 0 0 00 or higher...

Page 3: ...ng a thunderstorm Deviation could lead to electric shock Do not disassemble and or modify this Switching Hub Deviation could lead to fire electric shock and or equipment failure Do not damage the powe...

Page 4: ...b at the location with continuous vibration or strong shock or at the unstable location Deviation could lead to injury and or equipment failure Do not install any module other than the separately sold...

Page 5: ...Deviation could lead to electric shock malfunction and or equipment failure Connect the power cord firmly to the power port Deviation could lead to electric fire shock and or malfunction Unplug the p...

Page 6: ...ot touch the metal terminal of the RJ45 connector the modular plug of connected twisted pair cable or the metal terminal of the SFP extension slot Do not place charged objects in the proximity of them...

Page 7: ...ure and or malfunction When stacking Switching Hubs leave a minimum of 20 mm space between them Operation is not guaranteed if a module other than the optional SFP extension modules PN54022 PN54024 is...

Page 8: ...to 19 inch Rack 21 3 Connection 22 3 1 Connection Using a Twisted Pair Port 22 3 2 Connection Using an SFP Extension Slot 23 3 3 Connection to Power 24 4 Configuration 25 4 1 Connecting via Console P...

Page 9: ...tic Monitoring Menu 223 4 7 11 Static Multicast Address 226 4 8 Statistics 228 4 9 Switch Tools Configuration 233 4 9 1 TFTP Software Upgrade 234 4 9 2 Configuration File Upload Download 237 4 9 3 Sys...

Page 10: ...10 After sales Service 280...

Page 11: ...y connect devices with straight cables whether it is a terminal or a network device This function does not work if the port communication configuration is set at Fixed or Link Aggregation Ports 1 to 2...

Page 12: ...endix C Link aggregation function is supported Aggregation can be manually configured up to 8 ports Reboot timer function is supported enabling auto reboot after a scheduled time 24 hours or less Equi...

Page 13: ...nt Quantity Installation Guide this document 1 CD ROM PDF version of Operating Instructions 1 Mounting bracket for 19 inch rack 2 Screws for 19 inch rack 4 Screws for fixing the main unit and the moun...

Page 14: ...14 1 3 Part Names Fig 1 3 Part Names Back panel Magnified Front panel...

Page 15: ...wer Green Light Power is ON Off Power is OFF ANY COL LED Collision Orange Light During half duplex operation packet collision is occurring in either port Off No packet collision STATUS ECO LED Status...

Page 16: ...According to switchover in the port LED display mode described previously display of port LED in each port changes as follows Port LED Display mode Behavior Description Left STATUS ECO Green Light Lin...

Page 17: ...17 Off No loop detection history Right Orange Light Shutting down by loop detection Off Not shutting down by loop detection Fig 1 4 Port LED...

Page 18: ...d the port will shut down again Remove the loop while the port is shut off The loop detection shut off function can be switched on off by keeping pressing the LED display switch button for more than 1...

Page 19: ...tatus of each port In status mode STATUS ECO LED lights in green ECO mode Regardless of whether a device is connected or not all LEDs other than POWER and STATUS ECO LEDs turn off to save power In ECO...

Page 20: ...20 If the port LED display mode is switched to other than STATUS ECO and then no operation is executed for more than 1 minute the mode automatically shifts to the base mode...

Page 21: ...ied 2 mounting brackets for 19 inch rack and 8 screws for fixing the main unit and the mounting bracket and fix the brackets to the main unit by tightening screws into 4 holes located at the sides The...

Page 22: ...erformance mode When a terminal or a LAN device without auto negotiation function is connected to this Switching Hub this Switching Hub automatically determines and sets the communication speed howeve...

Page 23: ...nection Connect this Switching Hub s TX port to the RX port of the connected device and this Switching Hub s RX port to the TX port of the connected device If a twisted pair cable and an SFP module ar...

Page 24: ...and connect the other end into an electric outlet This Switching Hub operates at 100 240 V 50 60 Hz This Switching Hub does not have a power ON OFF switch Plugging the power cord turns on this Switchi...

Page 25: ...P address first via the console port before accessing via Telnet or SSH 4 1 Connecting via Console Port Console connection requires a DEC VT100 compatible asynchronous terminal or a terminal capable o...

Page 26: ...ere is no error in configuration of communication mode and others Fig 4 2 1 Login Screen Console If accessing the Switching Hub via Telnet a similar login screen appears displaying Remote Management S...

Page 27: ...27 Fig 4 2 2 Login Screen Telnet PN28240i Remote Management System Version x x x xx MAC Address xx x xx xx xx xx Serial Number xxxxxxxxxxx Login Menu Login...

Page 28: ...e password correctly and press the Enter key Fig 4 2 3 Entering Password Both the login name and password can be changed For the detailed change procedure refer to 4 6 7 Note A password is displayed w...

Page 29: ...x IP Address 192 168 1 10 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 COMMAND Set I P Address Set Subnet M ask Set Default G ateway Set IP P a rameter Set I P v6 Address Q uit to previous menu C...

Page 30: ...ows the commands available on this screen Available commands differ on each screen Select a command from the list 6 Prompt Changes as you enter a command indicating what you need to enter next Follow...

Page 31: ...the previous menu enter the Q command The second line from the top shows the current menu name Fig 4 4 1 Main Menu PN28240i Local Management System Main Menu G eneral Information B asic Switch Configu...

Page 32: ...this Switching Hub s advanced functions such as VLAN link aggregation and QoS Statistics Shows this Switching Hub s statistical information Switch Tools Configuration Configures this Switching Hub s...

Page 33: ...240i Local Management System Main Menu General Information System up for 0day s 0hr s 1min s 59sec s Boot Code Version x xx xx Runtime Code Version x x x xx Serial Number xxxxxxxxxxx Hardware Informat...

Page 34: ...on Menu IPv6 PN28240i Local Management System Main Menu General Information System Address Information MAC Address xx xx xx xx xx xx IPv6 Address PrefixLen 128 IPv6 Link Local Address IPv6 Default Gat...

Page 35: ...the installation location of the Switching Hub No information is set on shipment Switch Contact Shows contact information of the Switching Hub No information is set on shipment System Address Informat...

Page 36: ...to 4 6 2a IPv6 Link Local Address Shows the Switching Hub s current IPv6 link local address is displayed because no address is set on shipment For configuration details refer to 4 6 2a IPv6 Default G...

Page 37: ...tch Configuration PN28240i Local Management System Main Menu Basic Switch Configuration Menu System A dministration Configuration System I P Configuration S N MP Configuration P ort Configuration Basi...

Page 38: ...Port Configuration Extend Configures extended port settings such as port name Port Configuration Power Saving Configures power saving mode for MNO series System Security Configuration Configures the s...

Page 39: ...esponding ID in the MIB This item is not editable Name Shows the system name No information is set on shipment Location Shows the installation location No information is set on shipment Contact Shows...

Page 40: ...ters or less L Set edit the installation location information Press L The command prompt changes to Enter system location Enter a Switching Hub location in 50 one byte characters or less C Set edit th...

Page 41: ...isplayed because no address is set on shipment Subnet Mask Shows the current subnet mask 0 0 0 0 is displayed because no address is set on shipment Default Gateway Shows the IP address of the router s...

Page 42: ...ault gateway A Set the IP address subnet mask and default gateway in succession Press A The command prompt changes to Enter IP address Enter the IP address of the Switching Hub Then the command prompt...

Page 43: ...tatus is disabled IPv6 Address PrefixLen Shows the current IPv6 address and prefix length 128 is displayed because no address is set on shipment IPv6 Link Local Address Shows the current IPv6 link loc...

Page 44: ...44 IPv6 Default Gateway Shows the IPv6 address of the router set as a current default gateway is displayed because no address is set on shipment...

Page 45: ...the SNMP manager settings SNMP Extend Configuration Configures the SNMP extend settings SNMP Trap Receiver Configuration Configures the SNMP trap receiver settings Quit to previous menu Returns to th...

Page 46: ...SNMP Management Configuration Menu opens E Configure the SNMP extend settings Press E The SNMP Extend Configuration Menu opens T Configure the trap receiver settings Press T The SNMP Trap Receiver Con...

Page 47: ...write operations are allowed Read Only Only the read operation is allowed IP Address Shows the IP address of the SNMP manager PN28240i Local Management System SNMP Configuration SNMP Management Config...

Page 48: ...nges to Enter IP address for manager Enter an IP address R Set an access privilege for an SNMP manager Press R The command prompt changes to Enter manager entry number Enter an SNMP manager entry numb...

Page 49: ...ess of the SNMP manager Available commands are listed below I Set an IP address for an SNMP manager Press I The command prompt changes to Enter manager entry number Enter an SNMP Management entry numb...

Page 50: ...previous menu Returns to the previous menu Available commands are listed below U Configure the SNMP user settings Press U The SNMP User Configuration Menu opens V Configure the SNMP view settings Pres...

Page 51: ...current SNMP user settings No Shows the entry number on the SNMP User List User Name Shows the SNMP user name Group Shows the group of the SNMP user PN28240i Local Management System SNMP Extend Config...

Page 52: ...for changing SNMP user Press O The command prompt changes to Enter User ID Enter an SNMP user entry number you wish to configure Then the Modify SNMP User Configuration Menu opens M Show additional in...

Page 53: ..._VIEW Shows the name of view to notify Authentication Shows the authentication method Auth key Shows the authentication key Privilege Shows the encryption scheme Privilege Key Shows the encryption key...

Page 54: ...the command prompt changes to Enter Key Enter a key A Set the authentication method Press A The command prompt changes to Enter Authentication Type Press M to select MD5 Press S to select SHA P Set t...

Page 55: ...the name of view to notify Authentication Shows the authentication method Auth key Shows the authentication key Privilege Shows the encryption scheme Privilege Key Shows the encryption key PN28240i Lo...

Page 56: ...the command prompt changes to Enter Key Enter a key A Set the authentication method Press A The command prompt changes to Enter Authentication Type Press M to select MD5 Press S to select SHA P Set t...

Page 57: ...type PN28240i Local Management System SNMP Extend Configuration Menu SNMP View Configuration Menu Total Entry 8 View Name Subtree View Type restricted 1 3 6 1 2 1 1 Included restricted 1 3 6 1 2 1 11...

Page 58: ...an SNMP view in 32 one byte characters or less Then the Create SNMP View Configuration Menu opens O Go to the screen for changing SNMP view Press O The command prompt changes to Please enber view nam...

Page 59: ...4 6 13 Create SNMP View Screen Description View Name Shows the SNMP View name Subtree Shows the SNMP View subtree View Type Shows the SNMP View type PN28240i Local Management System SNMP View Configur...

Page 60: ...e previous page A Register an additional OID in subtree Press A The command prompt changes to Enter OID Enter an OID Then the command prompt changes to Enter Type Press I to include OID Press E to exc...

Page 61: ...4 Modify SNMP View Screen Description View Name Shows the SNMP View name Subtree Shows the SNMP View subtree View Type Shows the SNMP View type PN28240i Local Management System SNMP View Configuration...

Page 62: ...e previous page A Register an additional OID in subtree Press A The command prompt changes to Enter OID Enter an OID Then the command prompt changes to Enter Type Press I to include OID Press E to exc...

Page 63: ...P Group name Ver Shows the SNMP version Level Shows the SNMP security level PN28240i Local Management System SNMP Extend Configuration Menu SNMP Group Configuration Menu Total Entry 5 Group Name Ver L...

Page 64: ...MP group Press O The command prompt changes to Please input the SNMP Group Name Enter an SNMP view in 32 one byte characters or less Then the command prompt changes to Please input the SNMP Group Vers...

Page 65: ...the SNMP version READ_VIEW Shows the SNMP read view WRITE_VIEW Shows the SNMP write view NOTIFY_VIEW Shows the SNMP notify view Level Shows the SNMP security level PN28240i Local Management System SN...

Page 66: ...view to read Press R The command prompt changes to Enter Read View Enter an SNMP view name in 32 one byte characters or less E Set a security level Press E The command prompt changes to Please input...

Page 67: ...the SNMP version READ_VIEW Shows the SNMP read view WRITE_VIEW Shows the SNMP write view NOTIFY_VIEW Shows the SNMP notify view Level Shows the SNMP security level PN28240i Local Management System SN...

Page 68: ...view to read Press R The command prompt changes to Enter Read View Enter an SNMP view name in 32 one byte characters or less E Set a security level Press E The command prompt changes to Please input...

Page 69: ...ps Type Shows the trap type v1 Sends SNMP v1 traps v2c Sends SNMP v2c traps IP Address Shows the IP address of a trap receiver PN28240i Local Management System SNMP Configuration SNMP Trap Receiver Co...

Page 70: ...Configure the trap sending settings when the link status changes Press D to open the Enable Disable Individual Trap Menu For configuration details refer to 4 6 3 C T Set a trap type Press T The comman...

Page 71: ...g Login Failure Shows the trap sending settings for a login failure Enabled The trap sending is enabled Disabled The trap sending is disabled Factory default setting Enabled Link Up Down Port Shows th...

Page 72: ...login failure Press L The command prompt changes to Enable or Disable Login failure trap E D Press E to enable the trap sending Press D to disable it P Add a port to which the trap is sent when its l...

Page 73: ...f the SNMP trap receiver Available commands are listed below I Set an IPv6 address for an SNMP trap receiver Press I The command prompt changes to Enter manager entry number Enter an SNMP trap receive...

Page 74: ...Down Auto Disabled Disabled 3 1000T Enabled Down Auto Disabled Disabled 4 1000T Enabled Down Auto Disabled Disabled 5 1000T Enabled Down Auto Disabled Disabled 6 1000T Enabled Down Auto Disabled Disab...

Page 75: ...Mode Shows the communication speed and full duplex half duplex settings The factory default setting is Auto for all ports Auto Auto negotiation mode 100 FDx 100F 100 Mbps full duplex 100 HDx 100H 100...

Page 76: ...o enable the auto negotiation mode Press N to disable it If N is selected the command prompt changes to Enter speed for port 10 100 Select a desired communication speed Upon setting the command prompt...

Page 77: ...Then the command prompt changes to Enable or Disable Auto MDl for port E D Press E to enable the function Press D to disable it As the change is applied the display on the screen is updated automatic...

Page 78: ...on Extend Menu Jumbo Status Disabled Port Trunk Type Link Port Name EAP Pkt FW 1 1000T Down Disabled 2 1000T Down Disabled 3 1000T Down Disabled 4 1000T Down Disabled 5 1000T Down Disabled 6 1000T Dow...

Page 79: ...hows the port type 100TX The port type is 10 100BASE TX 1000T The port type is 10 100 1000BASE T 1000X The port type is SFP extension port Link Shows the current link status Up Link is established suc...

Page 80: ...n the screen is updated automatically A A name can be assigned to each port Press A The command prompt changes to Select port number to be changed Enter a port number you wish to change Press 0 to cha...

Page 81: ...er saving mode Fig 4 6 23 Port Configuration Power Saving PN28240i Local Management System Basic Switch Configuration Port Configuration Power Saving Menu Port Link Trunk Type Mode Power saving EEE 80...

Page 82: ...settings The factory default setting is Auto for all ports Auto Auto negotiation mode 100 FDx 100F 100 Mbps full duplex 100 HDx 100H 100 Mbps half duplex 10 FDx 10F 10 Mbps full duplex 10 HDx 10H 10...

Page 83: ...e the mode Press D to disable it Press H to enable the power saving mode of giving priority to connectivity with another device As the change is applied the display on the screen is updated automatica...

Page 84: ...eb Server Status Enabled SNMP Agent Disabled IP Setup Interface Enabled Local User Name manager Syslog Transmission Disabled Login Method 1 2 Local None Method 1 Fail Action Method 2 COMMAND Set C ons...

Page 85: ...twork cameras The factory default setting is Enabled For instructions refer to Appendix C Enabled Access is enabled Disabled Access is disabled Local User Name Shows the current login user name The fa...

Page 86: ...Disable telnet server E D Press E to enable the access Press D to disable the access S Configure the SNMP access settings Press S The command prompt changes to Enable or Disable SNMP Agent E D Press...

Page 87: ...IUS Press N for no setting H Configure the SSH server settings Press H The SSH Server Configuration Menu opens For configuration details refer to the next section 4 6 7 g B Configure the LED base mode...

Page 88: ...Configuration PN28240i Local Management System System Security Configuration Telnet Access Limitation Menu Telnet Access Limitation Disabled No IP Address Subnet Mask 1 empty empty 2 empty empty 3 em...

Page 89: ...55 255 254 192 168 1 20 192 168 1 21 Two units can be accessed 3 192 168 2 1 255 255 255 128 192 168 2 1 192 168 2 127 127 units can be accessed 4 192 168 3 1 255 255 255 0 192 168 3 1 192 168 3 254 2...

Page 90: ...ion Configuration PN28240i Local Management System Telnet Access Limitation Menu IPv6 Telnet Access Limitation Menu Telnet Access Limitation Enabled No IPv6 Address Prefixlen 1 empty empty 2 empty emp...

Page 91: ...refixlen Access permitted IP address 1 2001 1 1 128 2001 1 1 Only one unit can be accessed 2 2001 2 1 1 127 2001 2 1 0 2001 1 2 1 1 Two units can be accessed 3 2001 3 1 1 126 2001 3 1 0 2001 3 1 3 Fou...

Page 92: ...ts this common key No common key is set at shipment Response Time Shows the maximum response time for authentication request to RADIUS server The factory default setting is 10 seconds Max Retransmissi...

Page 93: ...RADIUS server index Enter a RADIUS server entry number between 1 and 5 The command prompt changes to Enter secret string for server with encryption Enter a common key within 20 one byte characters R S...

Page 94: ...are listed below N Set a NAS ID NAS Identifier Press N The command prompt changes to Enter NAS ID Enter NAS ID within 16 one byte characters I Set an IPv6 address of RADIUS server Press I The command...

Page 95: ...cillity Shows the value of Facillity Include SysName IP Shows information to be added SysName Adds the SysName of this switch to the system log to be transmitted IP address Adds the IP address of this...

Page 96: ...mand prompt changes to Enter IP address for manager Enter the IP address of Syslog server Y Sent information that is added to the system log to be transmitted Press Y The command prompt changes to Ent...

Page 97: ...ess is set on shipment Available commands are listed below I Set an IPv6 address of Syslog server Press I The command prompt changes to Enter manager entry number Enter a Syslog server entry number be...

Page 98: ...Retries Time Shows the number of retries for SSH authentication The factory default setting is 5 times SSH Server Shows the SSH access settings The factory default setting is Disabled Enabled SSH Acce...

Page 99: ...tomatically terminating an SSH connected session if no input is made Press O The command prompt changes to Enter SSH UI idle timeout Enter a value from 1 to 60 minutes A Set the response time to SSH a...

Page 100: ...isted below B Change the LED base mode Press B The command prompt changes to Select LED Base Mode S E Press S to change the LED base mode to the status mode Press E to change it to the ECO mode Q Retu...

Page 101: ...the MAC address of forwarding database MAC Learning Sets to Auto Off for the MAC address learning function of each port If this is set to OFF only MAC address registered in the Static Address Table is...

Page 102: ...s N The screen shows the next page P Show the previous page Press P The screen shows the previous page A Register an additional MAC address Press A The command prompt changes to Enter MAC Address xx x...

Page 103: ...is disabled MAC Learning Limit Shows the limit number of MAC address auto learning for each port Disabled The number of MAC address auto learning is not limited Factory default setting 1 256 Indicate...

Page 104: ...tus of auto learning Press S The command prompt changes to Select Port Number to be changed Enter a port number you wish to change the setting Then the command prompt changes to Change MAC Learning Mo...

Page 105: ...C address table Port Shows the port to which the MAC address has belonged Available commands are listed below N Show the next page Press N The screen shows the next port P Show the previous page Press...

Page 106: ...onization setting by SNTP Fig 4 6 37 Configuring of Time Synchronization Function before configuration PN28240i Local Management System Basic Switch Configuration Time Configuration Menu Time HH MM SS...

Page 107: ...NTP server Time Zone Shows the time zone Daylight Saving Shows the application status of Daylight Saving Summer time PN28240i Local Management System Basic Switch Configuration Time Configuration Menu...

Page 108: ...g is 1440 minutes 1 day E Set the application status of Daylight Saving Summer time Press E The command prompt changes to Enable or Disable Daylight Saving E D Enter E to use daylight saving time Pres...

Page 109: ...ut Shows the age out time of ARP table IP Address Shows the IP address on ARP table Hardware Address Shows the hardware address on ARP table Type Shows the type on ARP table Static The address is manu...

Page 110: ...method for sorting entry to display I T Press I to display in the order of IP address Press T to display in the order of type If T is selected the command prompt changes to Select type for sorting en...

Page 111: ...Reachable Time Shows the NDP Reachable time NDP State Time Shows the NDP Stale time IPv6 Address Shows the IPv6 Address on NDP table Hardware Address Shows the hardware address on NDP table Status Sh...

Page 112: ...NDP table with a value of 0 to 86400 seconds A Add modify an entry of NDP table Press A The command prompt changes to Enter IPv6 address Enter an IPv6 address Then the command prompt changes to Enter...

Page 113: ...Control Configuration Configures Storm Control function setting 802 1X Port Based Access Control Configuration Configures IEEE802 1X Port Based Access Control setting Loop Detection Configuration Con...

Page 114: ...114 Static Multicast Address Configuration Configures Static Multicast Address setting Quit to previous menu Quits the Advanced Switch Configuration Menu and returns to the Main menu...

Page 115: ...N ID VLAN ID is a VLAN identifier placed on each frame in processing tagged frames As for an untagged frame ports are divided into groups by this ID and the forwarding destination of the frame is dete...

Page 116: ...D of VLAN VLAN Name Shows the VLAN name being configured VLAN Type Shows the type of VLAN Permanent Indicates that the VLAN is the one of initial setting This VLAN cannot be deleted Static Indicates t...

Page 117: ...e Internet Mansion Function E D Press E to enable the function Press D to disable it If E is selected the command prompt changes to Uplink port Enter a port number you wish to configure as an uplink p...

Page 118: ...iguration screen in Fig 4 7 4 and Fig 4 7 5 On deletion you cannot delete a VLAN whose ID is remained as a PVID Delete the VLAN after changing the PVID to another ID Note When Internet Mansion mode is...

Page 119: ...enu Screen Description VLAN ID Shows the VLAN ID VLAN Name Shows the VLAN name Port Member Shows the port number of the VLAN member PN28240i Local Management System VLAN Management VLAN Creation Menu...

Page 120: ...P Set a member of VLAN Press P The command prompt changes to Enter egress port number Enter a port number you wish to set When entering multiple port numbers delimit with comma with no space or hyphe...

Page 121: ...nu Screen Description VLAN ID Shows the VLAN ID VLAN Name Shows the VLAN name Port Member Shows the port number of the VLAN member Untagged Port Shows the port without adding VLAN tags PN28240i Local...

Page 122: ...byte characters P Set a member of VLAN Press P The command prompt changes to Enter egress port number Enter a port number you wish to set When entering multiple port numbers delimit with comma with n...

Page 123: ...ceived The factory default setting is 1 When a tagged packet is received destination port will be determined according to the tag regardless of PVID Acceptable Type Shows the type of received frame Ad...

Page 124: ...PVID with a value of 1 to 4094 F Set the type of received frame Press F The command prompt changes to Enter port number Enter a port number you wish to configure Then the command prompt changes to Sel...

Page 125: ...ctical physical port number to a port list of access control not a logical port created in Link Aggregation For details refer to 4 7 4 Note If port communication modes are mixed Link Aggregation canno...

Page 126: ...nter trunk group number Enter a target group number with a value of 1 to 8 Then the command prompt changes to Enter port members for group x Enter a port number to be added When entering multiple port...

Page 127: ...normally filtered and cannot be monitored On this screen you can configure port monitoring settings Fig 4 7 7 Port Monitoring Configuration PN28240i Local Management System Advanced Switch Configurat...

Page 128: ...ed port to which analyzer etc is connected Press S The command prompt changes to Enter port number Enter a target port number M Set a port to be monitored Press M The command prompt changes to Enter p...

Page 129: ...Maximum configurable number 81 Out Profile action Sets the action against input packet exceeding a committed rate Maximum configurable number 128 Port list Sets the list of applicable ports Maximum co...

Page 130: ...ddress DSCP Shows the priority information DSCP value Pro Shows the protocol Src L4 Port Shows the source port number of TCP UDP Dst L4 Port Shows the destination port number of TCP UDP PN28240i Local...

Page 131: ...ress O The Modify Classifier Menu opens Set modify the configuration in the same as the Create Classifier Configuration Menu M Show additional information on a classifier Press M to display informatio...

Page 132: ...Source MAC Mask Length Destination MAC Address Destination MAC Mask Length Source IP Address Source IP Mask Length Destination IP Address Destination IP Mask Length Source IPv6 Address PLen Destinati...

Page 133: ...of source MAC address Destination MAC Mask Length Shows the length bits of destination MAC address Source IP Address Shows the source IP address Source IP Mask length Shows the length bits of source...

Page 134: ...P address Then the command prompt changes to Enter source IP address mask length Enter a length bits of address mask E Set a destination IP address to be filtered Press E The command prompt changes to...

Page 135: ...o Enter source IPv6 address Enter a source IPv6 address Then the command prompt changes to Enter source IPv6 address mask length Enter a length bits of address mask N Set a destination IPv6 address to...

Page 136: ...Fig 4 7 12 On this screen you can refer to classifier information Fig 4 7 11 Classifier Configuration Menu 1 PN28240i Local Management System Access Control Configuration Classifier Configuration Menu...

Page 137: ...on MAC Address Shows the destination MAC address 802 1p Priority Shows the priority of IEEE802 1p VLAN ID Shows the VLAN ID TCP SYN Flag Shows whether a TCP SYN flag is set for filtering ICMP Type Sho...

Page 138: ...ifier Information Classifier Index 1 Source MAC Address Ignore Source MAC Address Mask Length Ignore Destination MAC Address Ignore Destination MAC Address Mask Length Ignore 802 1p Priority Ignore VL...

Page 139: ...ource IP Mask length Shows the length bits of source address mask Destination IP Address Shows the destination IP address Destination IP Mask length Shows the length bits of destination address mask S...

Page 140: ...Permit Shows whether a packet is denied or permitted Action Shows the execution mode in in profile Policed DSCP Marks the DSCP value Policed Precedence Marks the precedence value Policed CoS Marks th...

Page 141: ...dence value Policed CoS Mark the CoS value D Delete in profile Press D The command prompt changes to Enter in profile action index Enter an index number of the in profile to be deleted M Modify in pro...

Page 142: ...acket is denied or permitted Action Policed DSCP Marks the DSCP value Policed Precedence Marks the precedence value Policed CoS Marks the CoS value PN28240i Local Management System In Profile Action C...

Page 143: ...ts Press 2 to permit them S Set a DSCP value to be marked Press S The command prompt changes to Enter DSCP value Enter a DSCP value of 0 to 63 P Set a precedence value to be marked Press P The command...

Page 144: ...c burst size that can be transmitted exceeding the committed rate For burst size 4K 8K 16K 32K and 64K are used Deny Permit Shows whether a packet is denied or permitted Policed DSCP Shows a DSCP valu...

Page 145: ...te out profile Press D The command prompt changes to Enter out profile action Index Enter an Index number of the out profile to be deleted M Modify out profile Enter M The command prompt changes to En...

Page 146: ...acket is denied or permitted Committed Rate Shows the packet buffer rate Burst Size KB Shows the traffic burst size that can be transmitted exceeding the committed rate Burst size is fixed to 64K PN28...

Page 147: ...nter Out Profile action index Enter an index number with a value of 1 to 65535 C Set the committed rate Press C The command prompt changes to Enter committed rate Enter the committed rate with a value...

Page 148: ...in Link Aggregation Fig 4 7 18 Port List Configuration Menu Screen Description Total Entries Shows the number of port lists number of indexes created Index Shows the port list index number Port List...

Page 149: ...reated Then the command prompt changes to Enter port number Enter a port number to be included in the list D Delete a port list Press D The command prompt changes to Enter port list index Enter an ind...

Page 150: ...er of policies Policies are applied in ascending order of this sequence number In Profile Shows the in profile index number Out Profile Shows the out profile index number Port List Shows the port list...

Page 151: ...pt changes to Enable or Disable Policy Entry Press E to enable the policy Press D to disable it Enabled Enable a policy Disabled Disable a policy S Show the policy information Press S to display detai...

Page 152: ...the In Profile Action Configuration Menu Out Profile Index Shows the out profile index number created in the Out Profile Action Configuration Menu Port List Index Shows the port list index number crea...

Page 153: ...mber I Set an index number of applicable in profile Press I The command prompt changes to Enter in profile index Enter an index number of applicable in profile O Set an index number of applicable out...

Page 154: ...uration screen for traffic class Press T The Traffic Class Configuration Menu opens For configuration details refer to 4 7 5 a E Go to the configuration screen for bandwidth Press E The Egress Rate Li...

Page 155: ...mpt changes to Enable or Disable QoS E D Press E to enable the function Press D to disable it M Assign a priority level traffic class to a priority value of IEEE802 1p Press M The command prompt chang...

Page 156: ...e next page P Show the previous page Press P The screen shows the previous page B Set a bandwidth Press B The command prompt changes to Enter port number e g 1 3 5 24 Enter a port number to designate...

Page 157: ...changes to Enter port number e g 1 3 5 24 Enter a port number to designate Then the command prompt changes to Enable or Disable Status E D Press E to enable the bandwidth control Press D to disable it...

Page 158: ...ast traffic Enabled Storm control for multicast is enabled Disabled Storm control for multicast is disabled Factory default setting Threshold Shows the threshold number of packets Packet Per Second PN...

Page 159: ...Enable or Disable broadcast storm control status E D Press E to enable the broadcast control Press D to disable it M Enable disable the storm control for multicast traffic Press M The command prompt c...

Page 160: ...g 4 7 25 Authentication Status Configuration PN28240i Local Management System Advanced Switch Configuration Authentication Configuration Menu A uthentication Status Table Authentication L og G lobal A...

Page 161: ...rol or WEB authentication Local MAC Authentication Database Configuration Moves to the local MAC database configuration used in MAC authentication 802 1X Access Control Configuration Moves to the IEEE...

Page 162: ...ed host Fig 4 7 25 1 Authentication Status Table PN28240i Local Management System Authentication Configuration Authentication Status Table Total Hosts 0 Authorized Hosts 0 Auth Aging Time 1440 minutes...

Page 163: ...or WEB authentication MAC WEB The authentication type is MAC authentication or WEB authentication Auth Status Displays the authentication status Authorized Authentication is authorized Unauthorized A...

Page 164: ...rred is written to the switch If the switch is restarted or turned off when no log is being written an authentication log that has been recorded at that point is flushed Factory default setting 60 ID...

Page 165: ...e terminal connected to a specific port succeeded in MAC authentication using the RADIUS or local database and was assigned to a specific VLAN or it failed in authentication MAC Local Authorized XX XX...

Page 166: ...xxxxxxxxxx XX XX XX XX XX XX on Port xx to VLAN xxxx info 802 1X Local Rejected user xxxxxxxxxxxxxxxx XX XX XX XX XX XX on Port xx notice MAC Rejected XX XX XX XX XX XX on Port xx auth table was full...

Page 167: ...al Management System Authentication Configuration Global Authentication Configuration Menu Global MAC Auth Status Disabled Global WEB Auth Status Disabled 802 1X Port based Auth Ports 1 24 802 1X MAC...

Page 168: ...re the MAC authentication status settings of the entire device Press M The command prompt changes to Enable or Disable global MAC auth status E D Press E to enable the status or D to disable it W Conf...

Page 169: ...in IEEE802 1X access control and WEB authentication Fig 4 7 25 4 Local User Database Configuration PN28240i Local Management System Authentication Configuration Local User Database Configuration Menu...

Page 170: ...user Press D The command prompt changes to Enable or Disable global WEB auth status E D Press E to enable the status or D to disable it E Create a local user whose password is encrypted Press E The c...

Page 171: ...Screen Description Auth MAC Address Displays the MAC address that can be authenticated VLAN Displays the VLAN ID to be assigned after authentication PN28240i Local Management System Authentication Con...

Page 172: ...ID Enter a VLAN ID to be assigned after authentication with an integer between 1 and 4094 D Delete a MAC address Press D The command prompt changes to Enter the MAC Address xx xx xx xx xx xx Enter th...

Page 173: ...ecified port VLAN xxxx Displays in ascending order of MAC address on the specified VLAN ID Displays the ID of the MAC address displayed for each page MAC Address Displays the MAC address learned in th...

Page 174: ...entry the command prompt changes to Enter VLAN ID Enter a VLAN ID to be assigned after authentication with an integer between 1 and 4094 M Display the table in ascending order of MAC address T Display...

Page 175: ...on The supported authentication methods are EAP MD5 TLS and PEAP Fig 4 7 25 7 802 1X Access Control Configuration PN28240i Local Management System Authentication Configuration 802 1X Access Control Co...

Page 176: ...onfiguration Configures the IEEE802 1X access control function Force Authorized MAC Address Configuration Sets the force authorized MAC address Statistics Displays the IEEE802 1X statistics informatio...

Page 177: ...onfigure the IEEE802 1X global settings Fig 4 7 25 8 802 1X Global Configuration Menu PN28240i Local Management System 802 1X Access Control Configuration 802 1X Global Configuration Menu Primary Data...

Page 178: ...authentication fails in the Primary Database Stop fixed Stops the authentication process without performing authentication in the Secondary Database Only when the Primary Database is RADIUS and a RADI...

Page 179: ...uthorized MAC Address Operational Control Direction Both Administrative Control Direction Both Per Port Re auth Disabled Re Auth Timer Mode RADIUS Current PVID 1 Transmit Period 30 seconds Max Request...

Page 180: ...is switch does not receive packets from the applicable port Administrative Control Direction Displays the operation method at the time of authentication request Both Without authentication this switch...

Page 181: ...ommand prompt changes to Select Administrative Control Direction Both or In B I Press B to control transmission receiving or I to control receiving B Enabled only in MAC based access control T Set the...

Page 182: ...ntication timer RADIUS or Local R L Press R to use the re authentication time reported from the RADIUS Press L to use Re auth Period of this switch Z Initialize the authentication status Press Z The c...

Page 183: ...Both Administrative Control Direction Both Transmit Period 30 sec Max Request 2 Supplicant Timeout 30 sec Quiet Period 60 sec Serv Timeout 30 sec Re auth Period 3600 sec Force Auth MAC Timeout 3600 s...

Page 184: ...ation request The factory default setting is 2 Supplicant Timeout Displays the timeout for the client The factory default setting is 30 seconds Quiet Period The number of seconds to wait before reatte...

Page 185: ...t changes to Select Administrative Control Direction Both or In B I Press B to control transmission receiving or I to control receiving B Set the number of supplicants that can be authenticated Press...

Page 186: ...nges to Select re authentication timer RADIUS or Local R L Press R to use the re authentication time reported from the RADIUS Press L to use Re auth Period of this switch Z Initialize the authenticati...

Page 187: ...he device to be forcibly authorized Mask Displays the mask length of the registered MAC address Auth Status Displays the force authorization type Authorized The authentication type is force authorized...

Page 188: ...the command prompt changes to Enter mask length Enter an integer number between 1 and 48 Then the command prompt changes to Select auth status A U Press A for forced authorize Press U for force unauth...

Page 189: ...rent counter value has been accumulated It is the time that has passed since booting or rebooting Counter Name Displays each counter name Total Displays the value accumulated in the counter PN28240i L...

Page 190: ...values to the ones after reset of the counter values Press R The values are switched immediately to the ones after reset of the counter values The time indication at the upper right corner of the scre...

Page 191: ...time that has elapsed since resetting of the counters Counter Name Displays each counter name Total Displays the value accumulated in the counter PN28240i Local Management System 802 1x Access Contro...

Page 192: ...described below TxReqId Displays the number of EAP Request Identity frames transferred from the switch TxReq Displays the number of EAP Request frames transferred from the switch TxTotal Displays the...

Page 193: ...on settings used in the IEEE802 1X MAC based access control mode Fig 4 7 25 14 EAP Request Configuration PN28240i Local Management System 802 1x Access Control Configuration EAP Request Configuration...

Page 194: ...5 seconds Port Displays the port number EAP Request Displays the EAP Request transmission status Enabled Transmits EAP Requests to the MAC addresses registered in the unauthorized MAC address table a...

Page 195: ...al of EAP Requests Press E The command prompt changes to Enter new interval Enter an integer number between 1 and 3600 seconds S Change the EAP Request Mode status Press S The command prompt changes t...

Page 196: ...C Displays in the order of MAC address Port Narrows down by arbitrary port number Selected Port Displays the port number used when Display by is Port MAC Address Displays the unauthorized MAC address...

Page 197: ...Change to narrow down by port number Press P The command prompt changes to Enter port number Enter the target port number A Add or delete a MAC address to from the table Press A The command prompt cha...

Page 198: ...ion Configuration Menu Primary Database Local Auth Fail Action Stop Secondary Database None Auth Fail Block Time 60 seconds MAC Address Format for RADIUS Username Case Upper Delimiter Hyphen Delimited...

Page 199: ...in after an authentication failure Factory default setting 60 MAC Address Format for RADIUS Username Displays the MAC address format of the user name transmitted to the RADIUS server when the RADIUS s...

Page 200: ...or the user name of the RADIUS account Press C The command prompt changes to Select MAC address case U L Press U for uppercase or L for lowercase D Set the delimiter type of the MAC address used for t...

Page 201: ...18 WEB Authentication Configuration Menu PN28240i Local Management System Authentication Configuration WEB Authentication Configuration Menu Primary Database Local Auth Fail Action Stop Secondary Dat...

Page 202: ...cation in the Secondary Database Auth Fail Block Time Displays the time seconds before accepting the authentication process again after an authentication failure Factory default setting 60 Virtual IP...

Page 203: ...ail Block Time Press B The command prompt changes to Enter auth fail block time Enter the waiting time before restarting authentication with an integer between 1 and 65535 seconds I Set the Virtual IP...

Page 204: ...er Japanese in Unicode on this screen Use a terminal emulator supporting UTF 8 and set the kanji code to UTF 8 PN28240i Local Management System WEB Authentication Configuration WEB Page Contents Confi...

Page 205: ...anese in Unicode Password String Displays the text in the password input field Factory default setting Password You can use Japanese in Unicode Message Displays the display text in the message field Y...

Page 206: ...rs or less You can use Japanese in Unicode and the following HTML tags a b i u center right left font h1 h5 div span br p S Change the text in the description field Press S The command prompt changes...

Page 207: ...ig 4 7 25 21 Temporary DHCP Server Configuration Menu PN28240i Local Management System WEB Authentication Configuration Temporary DHCP Server Configuration Menu Temporary DHCP Server Status Disabled D...

Page 208: ...ss of the leased IP address The subnet mask is fixed to 255 255 255 0 Number of Leased IP Address Displays the number of leased IP addresses Factory default setting 32 Default Router Address Displays...

Page 209: ...The command prompt changes to Enter start of released IP address Enter the start address of the leased IP address N Change the maximum number of leased IP addresses Press N The command prompt changes...

Page 210: ...l Management System Authentication Configuration Dynamic VLAN Configuration Menu Accept RADIUS Attribute Enabled Port Current PVID Auth Status Guest Default 1 1 Authorized 2 1 Authorized 3 1 Authorize...

Page 211: ...vate Group ID is not reported from the RADIUS server Available commands are listed below N Display the next page Press N to display the next page P Display the previous page Press P to display to the...

Page 212: ...ct Mode Recovery Recovery Time 1 Down Forwarding Enabled Block Enabled 60 2 Down Forwarding Enabled Block Enabled 60 3 Down Forwarding Enabled Block Enabled 60 4 Down Forwarding Enabled Block Enabled...

Page 213: ...ach port Enabled The loop detection shut off function is enabled Factory default setting Port 1 to 22 Disabled The loop detection shut off function is disabled Factory default setting Port 23 to 24 Mo...

Page 214: ...e or hyphenate the continuous numbers Enter 0 to apply all ports S Set the status of recovery mode for auto recovery of the shutoff port Press S The command prompt changes to Select port number to be...

Page 215: ...he event occurred If the time is not set the accumulated running time since boot is shown Event Shows the description of the event occurred to the Switching Hub The loop detected on portX Indicates th...

Page 216: ...7 28 Fig 4 7 28 Example of Configuration Using Port Grouping This configuration allows communications between PC1 and Internet and among PC2 PC3 and Internet Note The loop detection shut off function...

Page 217: ...ber ports belonging to the port group PN28240i Local Management System Advanced Switch Configuration Port Group Configuration Menu Total Groups 0 Group ID Group Name Group Member Status COMMAND N ext...

Page 218: ...the next section 4 7 9 a D Delete a port group Press D The command prompt changes to Enter Port Group ID Enter a port group ID you wish to delete with a value of 1 to 256 M Go to the screen for chang...

Page 219: ...Group ID Shows the port group ID Group Name Shows the port group name being configured Port Members Shows member ports belonging to the port group PN28240i Local Management System Port Group Configura...

Page 220: ...Set a port group member Press P The command prompt changes to Enter egress port number Enter a port number you wish to set When entering multiple port numbers delimit with comma with no space or hyphe...

Page 221: ...odification Menu Screen Description Group ID Shows the port group ID Group Name Shows the port group name being configured Port Members Shows member ports belonging to the port group PN28240i Local Ma...

Page 222: ...byte characters or less P Set a port group member Press P The command prompt changes to Enter egress port number Enter a port number you wish to set When entering multiple port numbers delimit with c...

Page 223: ...s the Tx power Temp deg C Shows the Temparature Voltage V Shows the Voltage Bias Current mA Shows the bias current Status Shows the current value PN28240i Local Management System Advanced Switch Confi...

Page 224: ...224 High Alarm Shows the high alarm value High Warning Shows the high warning value Low Alarm Shows the low alarm value Low Warning Shows the low warning value...

Page 225: ...Configure the Voltage threshold settings Press V The command prompt changes to Auto or Manual A M Press A to set the SFP default value Press M to set the value manually If M is selected the command p...

Page 226: ...escription VLAN ID Shows the VLAN ID of multicast group Group MAC Address Shows the MAC address of multicast group Group Members Shows the ports of multicast group PN28240i Local Management System Adv...

Page 227: ...ges to Enter MAC address for multicast entry Enter a multicast group MAC address to be added Then the command prompt changes to Select group member Enter a port D Delete a Multicast group MAC address...

Page 228: ...Name Shows each counter name Total Shows each counter value Avg s Shows the average per second of each counter PN28240i Local Management System Main Menu Statistics Menu Port 1 Refresh 300 Sec Elapse...

Page 229: ...The command prompt changes to Select Port number Enter the port number you wish to display F Set the screen refresh mode Press F The command prompt changes to 1 for start to refresh 2 for set refresh...

Page 230: ...ystem Main Menu Statistics Menu Port 1 Refresh 300 Sec Elapsed Time Since System Reset 000 00 00 00 Counter Name Total Avg s Total RX Bytes 0 0 Total RX Pkts 0 0 Good Broadcast 0 0 Good Multicast 0 0...

Page 231: ...he screen shows the counter values of the previous port Disabled in Port 1 S Switch a target port Press S The command prompt changes to Select Port number Enter the port number you wish to display F S...

Page 232: ...es When the Jumbo status is enabled Shows the number of packets having a packet length greater than 9216 bytes Fragments Shows the number of error packets that have a packet length less than 64 bytes...

Page 233: ...configuration of this Switching Hub System Reboot Configures and executes the reboot of this Switching Hub Exception Handler Configures the operation when exception occurs in this Switching Hub Ping...

Page 234: ...used for update Image File Name Shows the file name of the firmware to be upgraded Reboot Timer Shows the time before rebooting after downloading the firmware You can set the time in the System Reboot...

Page 235: ...me of the firmware to be upgraded Press F The command prompt changes to Enter file name Specify the file name of the downloaded program within 30 one byte characters U Start upgrading Press D The comm...

Page 236: ...fter waiting for the time set by the Reboot Timer rebooting is automatically executed Fig 4 9 3 Download in Process Note Be sure not to turn off the power of the Switching Hub while upgrading the firm...

Page 237: ...ption TFTP Server IP Shows the IP address of the TFTP server to upload download the configuration Config File Name Shows the configuration file name PN28240i Local Management System Switch Tools Confi...

Page 238: ...30 one byte characters U Start uploading the configuration information Press U The command prompt changes to Upload file Y N Confirm whether or not you wish to start the process Confirm that all setti...

Page 239: ...lt Factory Default Except IP All settings except the IP address are reset to factory default Reboot Timer Shows the time between execution of the reboot command and actual reboot The factory default s...

Page 240: ...ory default Press I to save only the IP address setting and return the other settings to factory default R Execute the reboot Press R The command prompt changes to Are you sure to reboot the system Y...

Page 241: ...handler is disabled Exception Handler Mode Shows the method of exception handler Debug Message When the Switching Hub detects exception handler a debug message is displayed on the console screen Syst...

Page 242: ...pt changes to Enable or Disable Exception Handler E D Press E to enable the function Press D to disable it M Set the method of exception handler Press M The command prompt changes to Select Exception...

Page 243: ...as shown in Fig 4 9 7 On this screen you can select IPv4 or IPv6 ping command Fig 4 9 7 Ping Execution PN28240i Local Management System Switch Tools Configuration Ping Execution IPv 4 Ping Execution I...

Page 244: ...ing The factory default setting is 0 0 0 0 Number of Request Shows the number of times of ping The factory default setting is 10 times Timeout Value Shows the time before timeout occurs The factory de...

Page 245: ...ween 1 to 5 seconds E Execute the ping command Or clear the display Press E The command prompt changes to Execute Ping or Clean before Ping Data E C Press E to execute ping Press C to only clear the d...

Page 246: ...the ping The factory default setting is Number of Request Shows the number of times of ping The factory default setting is 10 times Timeout Value Shows the time before timeout occurs The factory defa...

Page 247: ...to 5 seconds E Execute the ping command Or clear the display Press E The command prompt changes to Execute Ping or Clean before Ping Data E C Press E to execute ping Press C to only clear the display...

Page 248: ...them for network management Fig 4 9 12 System Log Each event displayed on this screen links to an SNMP trap An event for which a trap is set is displayed here The relationships with traps are describ...

Page 249: ...e Pkts Indicates that receiving the packet under 64 Bytes Received the error packets Oversize Pkts Indicates that receiving the packet over 1518 Bytes Received the error packets Fragments Indicates th...

Page 250: ...ring function started Stop monitoring function Indicates that the monitoring function stopped RADIUS Info Accept Login via RADIUS Indicates that the login operation was executed via RADIUS and was suc...

Page 251: ...guration 1 to 2 Indicates that detected the configuration file 2 is broken and was copied the configuration file 1 to 2 Reset configuration 1 2 to default Indicates that detected the configuration fil...

Page 252: ...ted via TELNET and was rejected based on TELNET access limitation function System authentication failure Indicates that authentication from the SNMP manager failed Info Set IP via ipsetup interface IP...

Page 253: ...tory Default Except IP Indicates that Switching Hub was rebooted in the mode to return settings other than IP address to the factory default Start reboot timer xxx sec Indicates that started the reboo...

Page 254: ...dicates that SFP module status was changed RX power Indicates that SFP Rx power status was changed TX power Indicates that SFP Tx power status was changed Temperature Indicates that SFP temarature sta...

Page 255: ...ng is Disabled Enabled The function is enabled Disabled The function is disabled Available commands are listed below W Enable disable the Watch Dog Timer function Press W The command prompt changes to...

Page 256: ...his screen the command prompt shows Save current configuration Y N Press Y to save the configuration Press N to cancel it If you don t save the configuration on this screen it will be deleted when the...

Page 257: ...g 4 10 2 Saving Configuration to Flash screen Completion of save PN28240i Local Management System Main Menu Save Configuration to Flash Saving configuration to flash is successful press any key to con...

Page 258: ...ig 4 11 1 On this screen you can use the command line for configuration instead of the menu screen For configuration procedure refer to the separate volume Operation Manual CLI Enter logout at the com...

Page 259: ...Q on the Main Menu opens the login screen shown in Fig 4 2 1 If you access using Telnet pressing Q terminates the connection To login again follow the login procedures shown in the section 4 2 You ar...

Page 260: ...00BASE T SFP 1 488 000 pps MAC address table 8K entries unit Buffer memory 512 KBytes Flow control IEEE 802 3x full duplex Back pressure half duplex Major functions IEEE 802 1Q Tag VLAN 256 VLANS max...

Page 261: ...MIB RFC 2574 SNMP VIEW BASED ACM MIB RFC 2575 SNMP COMMUNITY MIB RFC 2576 IP MIB RFC 4293 IF MIB RFC 2863 IEEE8021 PAE MIB Not support dot1xPaeSupplicant Power supply specifications Power supply AC 1...

Page 262: ...igured only with the software Easy Config In the software the item is displayed as Camera name Restrictions The time for accepting setting changes is limited to 20 minutes after power on to ensure sec...

Page 263: ...directly uses In addition if a downstream Switching Hub is connected with a device such as a hub without loop detection function and a loop failure occurs under the device the downstream Switching Hu...

Page 264: ...ing Hub causing loop will be blocked You need to examine this type of network configuration and Switching Hub settings Fig 2 Precautions in using loop detection function Downstream Switching Hub 2 Dow...

Page 265: ...ct 0 sysName R W sysName 0 sysLocation R W sysLocation 0 sysServices RO sysServices 0 sysORLastChange RO sysORLastChange 0 sysORID RO sysORID 1 sysORDescr RO sysORDescr 1 sysORUpTime RO sysORUpTime 1...

Page 266: ...pInTraps RO snmpInTraps 0 snmpOutGetResponses RO snmpOutGetResponses 0 snmpOutTraps RO snmpOutTraps 0 snmpEnableAuthenTraps R W snmpEnableAuthenTraps 0 2 IF MIB RFC2863 2 1 interfaces MIB object Acces...

Page 267: ...scards RO ipOutDiscards 0 ipOutNoRoutes Ro ipOutNoRoutes 0 ipReasmTomeout RO ipReasmTomeout ipReasmReqds RO ipReasmReqds 0 ipReasmOKs RO ipReasmOKs 0 ipReasmFails RO ipReasmFails 0 ipFragOKs RO ipFrag...

Page 268: ...InterfaceEnableStatus ipv6IfIndex ipv6InterfaceReachableTi me RO ipv6InterfaceReachableTime ipv6IfIndex ipv6InterfaceRetransmitTi me RO ipv6InterfaceRetransmitTime ipv6IfIndex ipv6InterfaceForwarding...

Page 269: ...tatsOutFragFail s RO ipSystemStatsOutFragFails ipSysVersion ipSystemStatsOutFragCre ates RO ipSystemStatsOutFragCreates ipSysVersion ipSystemStatsOutTransmi ts RO ipSystemStatsOutTransmits ipSysVersio...

Page 270: ...StatsReasmReqds ipVersion IfIndex ipIfStatsReasmOKs RO ipIfStatsReasmOKs ipVersion IfIndex ipIfStatsReasmFails RO ipIfStatsReasmFails ipVersion IfIndex ipIfStatsInDiscards RO ipIfStatsInDiscards ipVer...

Page 271: ...4188 4 1 dot1dBase MIB object Access Identifier Remar ks dot1dBaseBridgeAddress RO dot1dBaseBridgeAddress 0 dot1dBaseBridgeAddress RO dot1dBaseBridgeAddress 0 dot1dBaseNumPorts RO dot1dBaseNumPorts 0...

Page 272: ...ol R W dot1xAuthAuthControlledPortControl port_num dot1xAuthQuietPeriod R W dot1xAuthQuietPeriod port_num dot1xAuthTxPeriod R W dot1xAuthTxPeriod port_num dot1xAuthSuppTimeout R W dot1xAuthSuppTimeout...

Page 273: ...thFailWhileAuthenticating port_num dot1xAuthAuthReauths While Authenticating RO dot1xAuthAuthReauthsWhileAuthenticating port_num dot1xAuthAuthEapStarts While Authenticating RO dot1xAuthAuthEapStartsWh...

Page 274: ...RO etherStatsDropEvents etherIndex etherStatsOctets RO etherStatsOctets etherIndex etherStatsPkts RO etherStatsPkts etherIndex etherStatsBroadcastPkts RO etherStatsBroadcastPkts etherIndex etherStatsM...

Page 275: ...dentifier Remar ks snmpUnknownSecurityM odels RO snmpUnknownSecurityModels 0 snmpInvalidMsgs RO snmpInvalidMsgs 0 snmpUnknownPDUHandl ers RO snmpUnknownPDUHandlers 0 9 SNMP notification MIB RFC2573n 9...

Page 276: ...mStats MIB object Access Identifier Remar ks usmStatsUnsupportedSec Levels RO usmStatsUnsupportedSecLevels 0 usmStatsNotInTimeWind ows RO usmStatsNotInTimeWindows 0 usmStatsUnknownUserN ames RO usmSta...

Page 277: ...ect Access Identifier Remar ks vacmViewSpinLock R W vacmViewSpinLock 0 vacmViewTreeFamilyMas k R C vacmViewTreeFamilyMask snmp_view_name vacmViewTreeFamilyType R C vacmViewTreeFamilyType snmp_view_nam...

Page 278: ...Traps 14 1 Trap description Access Identifier Remar ks Cold Start Link up Down Login Failure Authentication Failure mnoBusAccessErrorNotifi cation ObjectID 1 3 6 1 4 1 396 5 5 1 6 mnoLoopDetection Obj...

Page 279: ...OP HISTORY LED blinks in orange This is to notify that there is a port in which a loop is occurring or has been removed within 3 days 2 Communications are slow Communications with all ports are imposs...

Page 280: ...to the shop where you purchased this Switching Hub Product name Model No Product serial No 11 alphanumeric characters labeled on the product Firmware version The number after Ver labeled on the unit p...

Page 281: ...haracters labeled on the product Shop Sales company Tel Customer service contact Tel You can check the version on the screen described in section 4 5 of this document Panasonic Life Solutions Networks...

Reviews: